{"title":"BRADFORD WHITE","description":"","products":[{"product_id":"bradford-white-415-43676-03-thermal-switch","title":"Bradford White 415-43676-03 Thermal Switch","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-43676-03 Thermal Switch\u003c\/strong\u003e is a critical safety component designed for \u003cstrong\u003eatmospheric vent gas water heaters\u003c\/strong\u003e and \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e models. This \u003cstrong\u003eL290F reset thermal switch\u003c\/strong\u003e operates as a secondary high-limit safety, engineered to interrupt the electrical or thermocouple circuit if internal temperatures exceed \u003cstrong\u003e290 degrees Fahrenheit\u003c\/strong\u003e. As a veteran-grade \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e, the 415-43676-03 ensures the integrity of the combustion chamber by preventing overheating conditions that could lead to system damage or safety hazards.\u003c\/p\u003e\n\n\u003cp\u003eThis \u003cstrong\u003emanual reset thermal switch\u003c\/strong\u003e is the direct \u003cstrong\u003efactory authorized replacement\u003c\/strong\u003e for legacy part numbers \u003cstrong\u003e239-43676-03\u003c\/strong\u003e and \u003cstrong\u003e100167474\u003c\/strong\u003e. Featuring a distinct \u003cstrong\u003ered housing\u003c\/strong\u003e for quick field identification, the switch utilizes standard 1\/4-inch quick-connect terminals for seamless integration into existing harnesses. This component is frequently used in \u003cstrong\u003eBradford White MI30T, MI303T, and MI40T\u003c\/strong\u003e residential series. For HVACR professionals, verifying the underlying cause of a trip—such as restricted airflow or burner malfunction—is essential before utilizing the \u003cstrong\u003emanual reset button\u003c\/strong\u003e to restore operation.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Contractors:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Engineered specifically for Bradford White \u003cstrong\u003eflammable vapor ignition resistant (FVIR)\u003c\/strong\u003e systems, ensuring precise fitment and electrical calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Calibration:\u003c\/strong\u003e The \u003cstrong\u003e290°F trip point\u003c\/strong\u003e provides a reliable safety threshold for high-tolerance residential and commercial water heating applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResettable Design:\u003c\/strong\u003e Features a \u003cstrong\u003emanual reset button\u003c\/strong\u003e, allowing technicians to restore system function once the thermal excursion cause is diagnosed and corrected.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Identification:\u003c\/strong\u003e Color-coded \u003cstrong\u003ered thermal switch\u003c\/strong\u003e housing prevents installation errors with lower-temperature blue or yellow limit counterparts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Technician Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the L290F thermal switch keep tripping?\u003c\/strong\u003e\u003cbr\u003e\nFrequent tripping usually indicates poor combustion air supply, a clogged flame arrestor, or venting issues. Always inspect the \u003cstrong\u003ewater heater burner chamber\u003c\/strong\u003e for lint or dust accumulation before resetting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I substitute this with a 240F or 270F switch?\u003c\/strong\u003e\u003cbr\u003e\nNo. Swapping the \u003cstrong\u003e415-43676-03\u003c\/strong\u003e with a different temperature rating will compromise the safety logic of the \u003cstrong\u003egas control valve\u003c\/strong\u003e and may lead to premature shutdowns or hazardous operating conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this switch compatible with the Honeywell burner assembly?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003ereset thermal switch\u003c\/strong\u003e is the standard component for many \u003cstrong\u003eHoneywell-equipped Bradford White\u003c\/strong\u003e atmospheric units requiring an L290F limit.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643549708,"sku":"415-43676-03","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/bradford-white-239-43676-03-switch-21_92cebce9-c7e4-482e-af99-bf852961a69e.jpg?v=1516063694"},{"product_id":"bradford-white-233-41831-00-limit-switch","title":"Bradford White 233-41831-00 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-41831-00 Limit Switch\u003c\/strong\u003e is a critical safety component engineered for \u003cstrong\u003eTTW1-10\u003c\/strong\u003e and \u003cstrong\u003eTTW1-12 'L' models\u003c\/strong\u003e. This \u003cstrong\u003e130-180F Auto Limit Switch\u003c\/strong\u003e provides precise thermal monitoring, functioning as a high-limit safety cut-off that automatically interrupts the electrical circuit if internal temperatures exceed safe operating parameters. Designed for \u003cstrong\u003eAC\/DC power sources\u003c\/strong\u003e, this panel-mount \u003cstrong\u003etemperature switch\u003c\/strong\u003e ensures the burner or heating elements shut down properly to prevent overheating and potential equipment damage. As a genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e (also identified by alternative SKU 415-41831-00), it offers a direct fit for \u003cstrong\u003eMITW40L\u003c\/strong\u003e and \u003cstrong\u003eMITW50L\u003c\/strong\u003e series water heaters. The 130°F to 180°F range provides reliable equipment protection across various \u003cstrong\u003eresidential gas water heater\u003c\/strong\u003e configurations. This robust \u003cstrong\u003eautomatic control device\u003c\/strong\u003e is essential for technicians performing routine maintenance or troubleshooting pilot light failures and thermal triad issues in \u003cstrong\u003eThrough-The-Wall\u003c\/strong\u003e venting systems.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Calibration:\u003c\/strong\u003e Operating range of 130-180°F ensures accurate safety triggering for high-demand applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Exact replacement for \u003cstrong\u003eBradford White TTW1-10\/12 'L'\u003c\/strong\u003e series and \u003cstrong\u003eMITW\u003c\/strong\u003e models, maintaining original system integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset Function:\u003c\/strong\u003e The \"Auto\" designation means the switch resets itself once temperatures return to the safe operating zone, reducing unnecessary service calls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Engineered with high-quality materials to withstand the high-temperature environments typical of power-vented gas water heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes a Bradford White limit switch to trip?\u003c\/strong\u003e\u003cbr\u003e\nTripping is typically caused by excessive water temperature, poor venting airflow, or scale buildup on the heating elements. If the switch trips frequently, professionals should inspect the blower assembly and thermostat settings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 233-41831-00 a manual or automatic reset switch?\u003c\/strong\u003e\u003cbr\u003e\nThis specific model is an \u003cstrong\u003eauto limit switch\u003c\/strong\u003e, meaning it does not require a manual button press to restore the circuit once the unit cools down. If the system fails to restart, it may indicate a permanent switch failure or a persistent over-temperature condition.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this switch in non-'L' TTW models?\u003c\/strong\u003e\u003cbr\u003e\nThis part is specifically cataloged for the \u003cstrong\u003e'L' model dash series\u003c\/strong\u003e. Cross-referencing the serial number is recommended as Bradford White often uses specific thermal profiles for different BTU ratings and tank sizes.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643677068,"sku":"233-41831-00","price":9.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_7e3f9c3c-2cff-4614-9ac4-06ce73f1fa88.jpg?v=1646094590"},{"product_id":"bradford-white-415-43448-00-ignitor","title":"Bradford White 415-43448-00 Ignitor","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-43448-00 Ignitor\u003c\/strong\u003e is a critical OEM component designed specifically for integration within the \u003cstrong\u003epilot assembly\u003c\/strong\u003e of various residential and commercial water heaters. As a high-performance \u003cstrong\u003ehot surface ignitor\u003c\/strong\u003e, this part ensures precise ignition cycles, mitigating lockout issues commonly associated with carbon buildup or element degradation in older units. This component serves as the \u003cstrong\u003edirect replacement for AP11941\u003c\/strong\u003e and \u003cstrong\u003e239-43448-00\u003c\/strong\u003e, maintaining the exact voltage requirements and physical dimensions necessary for a secure fit within the burner chamber. Built for longevity in high-heat environments, the \u003cstrong\u003e415-43448-00 ignition element\u003c\/strong\u003e provides the rapid thermal response required for efficient pilot light engagement. For technicians performing routine maintenance or emergency repairs, utilizing this \u003cstrong\u003egenuine Bradford White part\u003c\/strong\u003e ensures factory-spec compatibility, maintaining the operational integrity of the flue damper and gas control systems without the risks associated with universal aftermarket alternatives.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits for Contractors\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVerified Compatibility:\u003c\/strong\u003e Exact fit for \u003cstrong\u003eBradford White 415-43448-00\u003c\/strong\u003e and \u003cstrong\u003e239-43448-00\u003c\/strong\u003e systems, eliminating field modifications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced Reliability:\u003c\/strong\u003e Constructed with high-grade materials to withstand frequent thermal cycling in \u003cstrong\u003ewater heater pilot assemblies\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Plug-and-play design matches original wiring harnesses for faster service calls.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Performance:\u003c\/strong\u003e Maintains the specific resistance ranges required for the control board to verify flame rectification properly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat models are compatible with the 415-43448-00?\u003c\/strong\u003e\u003cbr\u003e\nThis ignitor is primarily used in Bradford White models featuring the Defender Safety System and certain high-efficiency atmospheric vent units. Always verify the part number against the rating plate on the water heater tank.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this to replace a 239-43448-00?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 415-43448-00 is the official manufacturer-designated supersession and direct replacement for the older 239-43448-00 part number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is my hot surface ignitor failing prematurely?\u003c\/strong\u003e\u003cbr\u003e\nPremature failure is often caused by touching the element with bare hands during installation (leaving oils) or issues with the gas valve delivering improper pressure. Always handle the 415-43448-00 by the ceramic base.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643677260,"sku":"415-43448-00","price":23.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_0962fe46-ac19-4d96-9abb-1e844cc72bfa.webp?v=1695934134"},{"product_id":"bradford-white-415-43676-01-switch","title":"Bradford White 415-43676-01 Switch","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-43676-01 Thermal Reset Switch\u003c\/strong\u003e is a critical safety component designed for atmospheric vent gas water heaters, specifically calibrated to treat over-temperature conditions. As a \u003cstrong\u003edirect replacement for 239-43676-01\u003c\/strong\u003e, this \u003cstrong\u003emanual reset thermal switch\u003c\/strong\u003e ensures the combustion chamber remains within safe operating parameters by interrupting the millivolt signal to the gas control valve if internal temperatures exceed 240°F. This \u003cstrong\u003eOEM water heater part\u003c\/strong\u003e features a distinct blue color-coding and spade terminal connections for seamless integration into the safety circuit of \u003cstrong\u003eMI30SF\u003c\/strong\u003e and \u003cstrong\u003eMI40TF\u003c\/strong\u003e series units.\u003c\/p\u003e\n\n\u003cp\u003eFor field technicians, this \u003cstrong\u003ethermal cutoff switch\u003c\/strong\u003e is a primary diagnostic point when troubleshooting burner lockout or pilot outages. A tripped switch often indicates restricted airflow, a blocked flue, or internal scaling, necessitating a full combustion system inspection before resetting. Utilizing an authentic \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e maintains the \u003cstrong\u003esystem's safety integrity\u003c\/strong\u003e and original manufacturer specifications, preventing nuisance trips while ensuring reliable flame rollout protection during high-demand cycles.\u003c\/p\u003e\n\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCritical Safety Cutoff:\u003c\/strong\u003e Automatically breaks the electrical circuit at 240°F to prevent hazardous overheating.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Engineered as the factory-authorized successor to the 239-43676-01 for precise fitment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eManual Reset Functionality:\u003c\/strong\u003e Protects the system by requiring a physical inspection and manual button depression after a trip event.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eContractor-Grade Construction:\u003c\/strong\u003e Features high-temp housing and standard quick-connect terminals for rapid field replacement.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Protection:\u003c\/strong\u003e Reduces the risk of damage to the gas control valve and tank components caused by abnormal heat accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes the Bradford White 415-43676-01 to trip repeatedly?\u003c\/strong\u003e\u003cbr\u003e\nPersistent tripping is typically caused by insufficient combustion air, a clogged flame arrestor, or venting obstructions. Techs should check for \"linting\" at the base of the heater or a restricted flue baffle.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I bypass this switch for testing purposes?\u003c\/strong\u003e\u003cbr\u003e\nBypassing is strictly for temporary continuity testing. Running a unit without a functional thermal switch creates a significant safety hazard and may lead to combustion chamber damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this switch compatible with LP (Propane) models?\u003c\/strong\u003e\u003cbr\u003e\nThis switch is primarily configured for specific Natural Gas MI series models. Always verify the part number against the unit's rating plate to ensure the 240°F set point matches the original design.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643789324,"sku":"415-43676-01","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_22b9696f-7468-4827-999a-6047d7bae23d.jpg?v=1604360609"},{"product_id":"bradford-white-415-43676-02-limit-switch","title":"Bradford White 415-43676-02 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-43676-02 Limit Switch\u003c\/strong\u003e is a critical safety component engineered for high-temperature monitoring in residential and commercial atmospheric water heaters. As a direct factory replacement for legacy part numbers \u003cstrong\u003e239-43676-02\u003c\/strong\u003e and \u003cstrong\u003e239-43676-02C\u003c\/strong\u003e, this \u003cstrong\u003eL270F manual reset limit switch\u003c\/strong\u003e ensures precise thermal cut-off performance. Designed to open at 270°F, it serves as a fail-safe against overheating conditions within the combustion chamber or flue collector. This \u003cstrong\u003eOEM water heater part\u003c\/strong\u003e features a manual reset mechanism, requiring a technician to inspect the system for venting or flame rollout issues before restoration. For contractors performing \u003cstrong\u003etank water heater repair\u003c\/strong\u003e, this switch provides exact electrical continuity specifications and mounting alignment for Bradford White Defender Safety System models. Utilizing \u003cstrong\u003egenuine Bradford White replacement parts\u003c\/strong\u003e ensures the manifold pressure and thermal safety parameters remain within original manufacturer tolerances for reliable long-term operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Protection:\u003c\/strong\u003e Fixed 270° Fahrenheit trip point prevents tank damage and hazardous operating conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Fit:\u003c\/strong\u003e Drop-in compatibility for \u003cstrong\u003eBradford White 239-43676-02\u003c\/strong\u003e enables fast field installation without bracket modification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManual Reset Safety:\u003c\/strong\u003e Prevents automatic cycling of a compromised unit, forcing an inspection of the combustion system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Durability:\u003c\/strong\u003e Constructed with materials rated for the intensive heat cycles of gas-fired water heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if my 415-43676-02 limit switch has tripped?\u003c\/strong\u003e\u003cbr\u003e\nIf the water heater is not heating and there is no continuity across the switch terminals during a multi-meter test, the \u003cstrong\u003eL270F limit switch\u003c\/strong\u003e has likely tripped due to excessive internal temperatures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this switch compatible with older Bradford White Defender models?\u003c\/strong\u003e\u003cbr\u003e\nYes, this is the official \u003cstrong\u003ereplacement limit switch\u003c\/strong\u003e for several generations of the Defender series, including those using the 239-43676-02C part number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes this limit switch to trip frequently?\u003c\/strong\u003e\u003cbr\u003e\nFrequent tripping is often indicative of \u003cstrong\u003eflame rollout\u003c\/strong\u003e, restricted venting, or a clogged \u003cstrong\u003eScreenCheck flame arrestor\u003c\/strong\u003e, all of which cause heat to build up near the switch mounting point.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643789964,"sku":"415-43676-02","price":30.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/bradford-white-239-43676-02-switch-18_9006130b-b55e-4ebd-9b92-c0494a144804.jpg?v=1516063693"},{"product_id":"233-46501-24","title":"Bradford White 233-46501-24 Thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-46501-24\u003c\/strong\u003e is a technical-grade \u003cstrong\u003e24-inch thermocouple\u003c\/strong\u003e designed for precise flame sensing and safety shut-off in residential and commercial gas water heaters. As a veteran-preferred \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e, this component is engineered to generate the necessary millivoltage to hold the \u003cstrong\u003egas control valve\u003c\/strong\u003e open during the heating cycle. It serves as the primary safety mechanism, ensuring that fuel flow is immediately terminated if the pilot flame is extinguished, preventing hazardous gas accumulation. This specific 24\" lead allows for proper routing through the combustion chamber while maintaining a secure connection to the \u003cstrong\u003eWhite-Rodgers gas valve\u003c\/strong\u003e or compatible safety systems.\u003c\/p\u003e\n\n\u003cp\u003eFor contractors servicing \u003cstrong\u003eBradford White Defender Safety System\u003c\/strong\u003e models, the 233-46501-24 provides the reliable thermal-to-electrical conversion required for consistent pilot monitoring. It is a direct service replacement for part numbers 415-46501-24 and 233-33044-16, commonly found in 30 to 75-gallon atmospheric and direct vent units. When troubleshooting a pilot that won't stay lit despite a clean orifice, installing this \u003cstrong\u003eheavy-duty thermocouple\u003c\/strong\u003e restores the integrity of the safety circuit. The \u003cstrong\u003ethreaded connection\u003c\/strong\u003e ensures a gas-tight fit, minimizing millivolt drop and reducing nuisance service calls.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Fits a broad range of \u003cstrong\u003eBradford White gas water heaters\u003c\/strong\u003e, including DH50T50F, DH65T55F, and DH75T60F models.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized 24-Inch Length:\u003c\/strong\u003e Provides ample reach for standard burner assemblies while ensuring the tip remains correctly positioned in the pilot flame.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Precision:\u003c\/strong\u003e Guaranteed \u003cstrong\u003egenuine Bradford White part\u003c\/strong\u003e performance, maintaining the factory-specified millivolt signal for gas valve operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Vital component for the \u003cstrong\u003eflame safety circuit\u003c\/strong\u003e, preventing gas flow in the absence of a stable ignition source.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWill this thermocouple fix a pilot light that keeps going out?\u003c\/strong\u003e\u003cbr\u003e\nIf the pilot flame is clean and hitting the probe but the valve won't hold, the \u003cstrong\u003ethermocouple\u003c\/strong\u003e is likely degraded and failing to produce the required voltage to energize the valve coil.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 233-46501-24 compatible with the Defender Safety System?\u003c\/strong\u003e\u003cbr\u003e\nYes, this 24\" lead is a standard \u003cstrong\u003eservice replacement\u003c\/strong\u003e for components within the Defender series combustion chambers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this replace the 16-inch or 19-inch versions?\u003c\/strong\u003e\u003cbr\u003e\nWhile the 24-inch length can replace shorter leads, it is specifically designed for units requiring a \u003cstrong\u003elong-reach thermocouple\u003c\/strong\u003e to ensure proper routing without tension on the connections.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643923980,"sku":"415-34790-12","price":35.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/bradford-white-233-46501-24-thermocouple-18_9f8efb6c-14ad-4cec-b4cc-66ba65b92956.png?v=1516063693"},{"product_id":"bradford-white-415-46501-15-thermocouple","title":"Bradford White 415-46501-15 Thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-46501-15 Thermocouple\u003c\/strong\u003e is a high-precision 15-inch temperature sensing component engineered for gas-fired water heaters. As a critical safety device, it operates via the Seebeck effect, generating a millivolt signal to the gas valve to maintain the pilot circuit. This specific \u003cstrong\u003eOEM water heater replacement part\u003c\/strong\u003e is the factory-authorized successor to the \u003cstrong\u003e233-46501-15\u003c\/strong\u003e, ensuring seamless integration with original equipment specifications. \n\nTechnicians prefer this \u003cstrong\u003egenuine Bradford White thermocouple\u003c\/strong\u003e because it features a shielded design to resist environmental interference and high-grade metal alloy construction for thermal stability. Replacing a faulty sensor with this \u003cstrong\u003e15-inch thermocouple kit\u003c\/strong\u003e prevents unexpected pilot outages and ensures the gas supply shuts off if the flame is lost. This part arrives in original factory packaging, maintaining the integrity required for professional HVACR maintenance and commercial-grade reliability.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Integration:\u003c\/strong\u003e Engineered by Bradford White as the exact replacement for the \u003cstrong\u003e233-46501-15\u003c\/strong\u003e model, eliminating the need for universal modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Safety Profile:\u003c\/strong\u003e Critical \u003cstrong\u003egas water heater safety part\u003c\/strong\u003e that prevents gas leakage by automatically closing the valve upon pilot failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built with high-grade materials to withstand the high-temperature environment of the combustion chamber.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e15-Inch Lead Length:\u003c\/strong\u003e Provides the specific reach required for internal routing within residential and commercial tank-type heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWill this work if my current part is 233-46501-15?\u003c\/strong\u003e Yes, the \u003cstrong\u003eBradford White 415-46501-15\u003c\/strong\u003e is the direct superseded part number for the 233-46501-15.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs this compatible with other brands?\u003c\/strong\u003e This is a brand-specific \u003cstrong\u003efactory-authorized replacement\u003c\/strong\u003e and is intended only for select Bradford White models. It is not a universal thermocouple.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow do I know if the thermocouple is bad?\u003c\/strong\u003e If your pilot light will not stay lit despite a strong flame touching the tip, the thermocouple is likely no longer producing the necessary millivoltage to hold the gas valve open.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35643988236,"sku":"415-46501-15","price":25.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_9047b232-3fe6-42ef-9c61-5d6f4ea1e205.png?v=1680548331"},{"product_id":"bradford-white-228-42506-00-burner","title":"Bradford White 228-42506-00 Burner","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 228-42506-00 Burner\u003c\/strong\u003e is a precision-engineered \u003cstrong\u003eBeckett burner head\u003c\/strong\u003e designed specifically for EN models. As a genuine \u003cstrong\u003eOEM water heater part\u003c\/strong\u003e, it ensures high-performance combustion and exact \u003cstrong\u003eflame control\u003c\/strong\u003e for atmospheric natural gas units. This \u003cstrong\u003enatural gas burner head\u003c\/strong\u003e is vital for maintaining the thermal efficiency of your gas-fired water heater, effectively resolving issues such as uneven heating or clogged burner ports. Built with \u003cstrong\u003edurable construction\u003c\/strong\u003e, it is optimized for high-demand residential and commercial applications, providing a reliable ignition source that integrates seamlessly with the original gas train assembly.\u003c\/p\u003e\n\n\u003cp\u003eFor a successful \u003cstrong\u003eBradford White burner replacement\u003c\/strong\u003e, technicians should verify compatibility with the specific model and serial number. This part is commonly utilized in Bradford White series such as the MI40T, DH50T, and DH65T. Replacing a deteriorated or misshapen burner head restores the \u003cstrong\u003eoptimal fuel efficiency\u003c\/strong\u003e of the system and prevents carbon buildup within the combustion chamber. Always inspect the \u003cstrong\u003eburner orifice\u003c\/strong\u003e and pilot assembly when performing this repair to ensure the entire ignition system operates according to factory specifications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect compatibility:\u003c\/strong\u003e Specifically engineered for \u003cstrong\u003eBradford White EN models\u003c\/strong\u003e using \u003cstrong\u003eBeckett burner\u003c\/strong\u003e technology.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Combustion:\u003c\/strong\u003e Provides \u003cstrong\u003eprecise flame control\u003c\/strong\u003e to maximize \u003cstrong\u003efuel efficiency\u003c\/strong\u003e and reduce emissions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional Grade:\u003c\/strong\u003e Heavy-duty \u003cstrong\u003edurable construction\u003c\/strong\u003e resists the high-temperature stresses of continuous water heater cycling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Standards:\u003c\/strong\u003e Guaranteed fit as an original \u003cstrong\u003eBradford White 228-42506-00\u003c\/strong\u003e replacement part, eliminating the risks of aftermarket alternatives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow do I know if the burner head needs replacing?\u003c\/strong\u003e Look for misshapen holes, heavy metal deterioration, or a yellow, lazy flame that indicates improper gas-air mixing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWill this fit any Bradford White water heater?\u003c\/strong\u003e No, this is intended for specific EN series models; always cross-reference your model and serial number before installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs the orifice included with this burner head?\u003c\/strong\u003e This SKU is typically the \u003cstrong\u003eburner head only\u003c\/strong\u003e; the main burner orifice may need to be ordered separately depending on your heater's BTU rating and altitude.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644341772,"sku":"228-42506-00","price":32.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_5571ba5e-faa5-4c5a-a984-80168f804b3e.jpg?v=1629328372"},{"product_id":"bradford-white-230-32920-01-relief-valve","title":"Bradford White 230-32920-01 Relief Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 230-32920-01 Relief Valve\u003c\/strong\u003e is a critical OEM safety component designed for precise \u003cstrong\u003etemperature and pressure protection\u003c\/strong\u003e in residential and commercial water heating systems. Engineered as a \u003cstrong\u003eT\u0026amp;P relief valve\u003c\/strong\u003e, this part features a \u003cstrong\u003e3\/4 inch NPT male inlet\u003c\/strong\u003e and a \u003cstrong\u003e4 inch stem\u003c\/strong\u003e (also recognized in some specifications as a 3 inch effective length) to ensure accurate thermal sensing within the tank. It is factory-set to discharge at a \u003cstrong\u003e150 PSI pressure rating\u003c\/strong\u003e or a maximum temperature of \u003cstrong\u003e210 degrees Fahrenheit\u003c\/strong\u003e, providing a necessary failsafe to prevent tank over-pressurization. This \u003cstrong\u003egenuine Bradford White part\u003c\/strong\u003e, often cross-referenced with \u003cstrong\u003e415-32920-01\u003c\/strong\u003e, is the standard replacement for various 1-inch insulated models, including the PowerStor Series SS and MI50L6BN15. For contractors, utilizing this \u003cstrong\u003eCSA certified\u003c\/strong\u003e and \u003cstrong\u003eASME rated relief valve\u003c\/strong\u003e ensures system integrity and maintains \u003cstrong\u003eHVACR equipment safety\u003c\/strong\u003e standards during routine maintenance or emergency repairs.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Action Safety:\u003c\/strong\u003e Simultaneously monitors and responds to both excessive internal tank pressure and dangerous thermal expansion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Exact fit for Bradford White \u003cstrong\u003eresidential water heater parts\u003c\/strong\u003e, including select PowerStor indirect models, ensuring \"plug-and-play\" installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Capacity Discharge:\u003c\/strong\u003e Rated for up to \u003cstrong\u003e105,000 BTU\/hr\u003c\/strong\u003e, providing sufficient venting capacity for standard residential and light commercial loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e Constructed with a durable brass body and 4-inch probe to withstand harsh potable water conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 230-32920-01 compatible with my specific water heater model?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003etemperature and pressure relief valve\u003c\/strong\u003e is designed for Bradford White units with 1-inch insulation. You should verify your specific model number, as T\u0026amp;P valves are model-specific components based on tank volume and BTU input.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between part number 230-32920-01 and 415-32920-01?\u003c\/strong\u003e\u003cbr\u003e\nThese parts are technically identical. Bradford White uses \u003cstrong\u003e415-32920-01\u003c\/strong\u003e as the service kit equivalent of the factory-installed \u003cstrong\u003e230-32920-01\u003c\/strong\u003e; they offer the same \u003cstrong\u003e150 PSI and 210°F\u003c\/strong\u003e protection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhen should a water heater relief valve be replaced?\u003c\/strong\u003e\u003cbr\u003e\nIn \u003cstrong\u003eHVACR maintenance\u003c\/strong\u003e, a T\u0026amp;P valve should be replaced if it shows signs of leaking, \"weeping,\" or mineral buildup around the discharge port, which can prevent the valve from seating correctly.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644587532,"sku":"415-32920-01","price":56.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_7bcb22c9-e662-4032-acea-d323d8ddecfb.jpg?v=1651783878"},{"product_id":"bradford-white-233-40248-05-pilot-assembly","title":"Bradford White 233-40248-05 Pilot Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-40248-05 Pilot Assembly\u003c\/strong\u003e is a critical OEM replacement part designed for specific \u003cstrong\u003enatural gas water heater\u003c\/strong\u003e models equipped with the \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e. This assembly functions as a direct replacement for the discontinued \u003cstrong\u003e233-41801-05B\u003c\/strong\u003e, ensuring continued reliable ignition and flame sensing. Engineered for high-temperature durability, this \u003cstrong\u003epilot burner assembly\u003c\/strong\u003e includes the \u003cstrong\u003ethermopile\u003c\/strong\u003e, \u003cstrong\u003ethermocouple\u003c\/strong\u003e, and \u003cstrong\u003eigniter wire\u003c\/strong\u003e required to restore the standing pilot system to manufacturer specifications. Proper installation maintains the integrity of the \u003cstrong\u003eCCT (Flammable Vapor Ignition Resistant)\u003c\/strong\u003e system, preventing nuisance shutdowns and intermittent combustion issues. When performing a \u003cstrong\u003ewater heater pilot repair\u003c\/strong\u003e, technicians should verify the orifice size and millivolt output to ensure compatibility with the existing gas control valve. This kit is built to withstand the rigorous cycling of residential and light commercial applications, providing the necessary thermal feedback to the gas valve for safe operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Specifically engineered for a precise fit within Bradford White combustion chambers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStreamlined Installation:\u003c\/strong\u003e Integrated lead wires and connectors reduce field labor time during \u003cstrong\u003epilot assembly replacement\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Supersession:\u003c\/strong\u003e Serves as the official factory-authorized substitute for part \u003cstrong\u003e233-41801-05B\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Reliability:\u003c\/strong\u003e High-grade sensors ensure consistent millivolt generation for stable burner operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is my Bradford White pilot not staying lit?\u003c\/strong\u003e\u003cbr\u003e\nA common cause is a degraded \u003cstrong\u003ethermopile\u003c\/strong\u003e or a clogged pilot orifice. If the voltage signal to the gas valve is insufficient, the safety magnet will drop out, extinguishing the flame. Replacing the entire \u003cstrong\u003e233-40248-05\u003c\/strong\u003e assembly ensures all ignition components are refreshed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this assembly on an LP (Propane) unit?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific part number is calibrated for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e. Using a natural gas pilot on an LP system creates a significant safety hazard due to incorrect orifice sizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does the 233-40248-05 include?\u003c\/strong\u003e\u003cbr\u003e\nThis is a complete \u003cstrong\u003epilot burner\u003c\/strong\u003e kit containing the pilot tube, electrode, and sensing elements, allowing for a comprehensive overhaul of the pilot system.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644593036,"sku":"233-40248-05","price":27.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_6bbe47f8-e41b-49b9-ad4c-39a5e4e95c16.png?v=1776879722"},{"product_id":"bradford-white-239-44723-01-pressure-switch","title":"Bradford White 239-44723-01 Pressure Switch","description":"\u003cp\u003eFor contractors maintaining Bradford White water heater systems, the \u003cstrong\u003eBradford White 239-44723-01 Pressure Switch\u003c\/strong\u003e is a critical OEM component. This genuine \u003cstrong\u003e2.48\" WC pressure switch\u003c\/strong\u003e is engineered to precise factory specifications, ensuring optimal performance and system integrity. It functions as a normally open (NO) switch, designed to accurately monitor and verify the operational status of the blower and vent system. Proper function of this \u003cstrong\u003eHVAC pressure switch replacement\u003c\/strong\u003e is paramount for safe and efficient combustion, preventing operational issues by confirming adequate airflow before ignition. Utilizing this authentic \u003cstrong\u003eBradford White water heater part\u003c\/strong\u003e guarantees seamless integration and reliable operation, maintaining the unit's designed safety parameters and overall efficiency. This specific part number, 239-44723-01, is often superseded or cross-referenced with 415-44723-01, both being identical in form, fit, and function for applicable models. Trust in \u003cstrong\u003eOEM pressure switch Bradford White\u003c\/strong\u003e quality for dependable system control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsures proper system operation by accurately monitoring vent system pressure.\u003c\/li\u003e\n\u003cli\u003eGenuine OEM component for guaranteed compatibility and reliable performance.\u003c\/li\u003e\n\u003cli\u003eMaintains safety protocols by verifying adequate airflow before ignition.\u003c\/li\u003e\n\u003cli\u003eDirect replacement for specific Bradford White water heater models, including cross-referenced part 415-44723-01.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIs this pressure switch compatible with my specific Bradford White water heater model and serial number?\u003c\/li\u003e\n\u003cli\u003eWhat are the typical indicators of a malfunctioning pressure switch in a Bradford White unit?\u003c\/li\u003e\n\u003cli\u003eHow can I confirm the correct pressure switch rating (e.g., 2.48\" WC) for my existing system?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644693132,"sku":"100166072","price":92.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_735a93bd-6873-4b98-9441-bef1304b7210.jpg?v=1626304480"},{"product_id":"bradford-white-239-44724-01-vacuum-switch","title":"Bradford White 239-44724-01 Vacuum Switch","description":"\u003cp\u003eMaintain peak combustion efficiency with the \u003cstrong\u003eBradford White 239-44724-01 Vacuum Switch\u003c\/strong\u003e, a critical OEM safety component for gas-fired water heating systems. This \u003cstrong\u003eintake vacuum switch\u003c\/strong\u003e is specifically calibrated to a \u003cstrong\u003e1.20 inch NC\u003c\/strong\u003e (Normally Closed) set point, ensuring the blower motor establishes proper draft before the ignition sequence initiates. As a genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e, it prevents burner operation under unsafe venting conditions, protecting the heat exchanger and residential environment from improper exhaust. Designed for 120V pilot circuits, this \u003cstrong\u003ewater heater pressure switch\u003c\/strong\u003e features high-temperature resistant housing and standard spade terminals for a secure electrical interface. For technicians performing diagnostics on power-vented units, this \u003cstrong\u003eHVAC vacuum switch\u003c\/strong\u003e is the primary solution for resolving pressure switch lockout codes. Always verify the specific \u003cstrong\u003epressure switch rating\u003c\/strong\u003e and model compatibility using the water heater's serial number to ensure precise pneumatic response and system safety.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Precision:\u003c\/strong\u003e Factory-calibrated to 1.20\" WC, ensuring exact compatibility with Bradford White power-vented draft transitions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombustion Safety:\u003c\/strong\u003e Interlocks the gas valve with venting pressure to prevent operation during flue blockages or blower failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Recovery:\u003c\/strong\u003e Resolves common \"Pressure Switch Failed to Close\" or \"Stayed Open\" error codes on residential gas units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Build:\u003c\/strong\u003e Engineered with durable diaphragms to withstand the rapid cycling and thermal demands of high-recovery water heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 239-44724-01 compatible with other brands?\u003c\/strong\u003e\u003cbr\u003e\nThis is an application-specific OEM component. While it may resemble generic switches, its specific 1.20\" NC trip point is engineered for Bradford White venting logic. Using an incorrect switch can lead to ignition failure or unsafe operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing intake vacuum switch?\u003c\/strong\u003e\u003cbr\u003e\nCommon signs include the blower fan running continuously without ignition, specific LED status codes (typically 2 or 3 flashes), or the burner shutting down shortly after startup due to a lost vacuum signal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I adjust the set point on this switch?\u003c\/strong\u003e\u003cbr\u003e\nNo, this switch is factory-sealed and non-adjustable. If the vacuum levels do not meet the 1.20\" NC requirement, technicians should inspect the venting, intake screens, and blower wheel for obstructions before replacing the switch.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644693516,"sku":"239-44724-01","price":47.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_d1022f28-c79e-44bf-a1db-4d29502b6a04.jpg?v=1625254996"},{"product_id":"bradford-white-265-43232-00-flame-sensor","title":"Bradford White 265-43232-00 Flame Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-43232-00 Flame Sensor\u003c\/strong\u003e is a critical safety component designed for precise flame rectification in residential atmospheric and power-vented water heaters. Also identified as a \u003cstrong\u003ewater heater flame rod\u003c\/strong\u003e or \u003cstrong\u003eigniter-flame sensor assembly\u003c\/strong\u003e, this OEM part monitors the burner's pilot or main flame, sending a microamp signal to the gas control valve to ensure safe operation. A fouled or oxidized sensor is a common cause of short-cycling or \u003cstrong\u003ewater heater ignition failure\u003c\/strong\u003e. This \u003cstrong\u003ereplacement flame sensor\u003c\/strong\u003e features a high-grade ceramic insulator and a durable metal alloy rod capable of withstanding the high-temperature environment within the combustion chamber. When diagnosing a unit that shuts down seconds after ignition, testing the \u003cstrong\u003emicroamp output\u003c\/strong\u003e of this sensor is the standard procedure. Regular inspection of the \u003cstrong\u003e265-43232-00 sensor\u003c\/strong\u003e prevents carbon buildup from interfering with the electrical circuit, ensuring reliable burner sequencing and preventing unnecessary service calls.\u003c\/p\u003e\n\n\u003cstrong\u003eTechnical Specifications and Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Precision-fit for specific Bradford White Defender Safety System and Power Vent models.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Conductivity:\u003c\/strong\u003e High-purity metal rod ensures a domestic water heater control detects the flame signal instantly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReduced Nuisance Tripping:\u003c\/strong\u003e Engineered to maintain signal stability even during fluctuations in gas pressure or combustion air.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Plug-and-Play:\u003c\/strong\u003e Features the correct lead length and terminal connector for efficient field replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Service Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow do I know if my flame sensor is bad?\u003c\/strong\u003e If the burner ignites but goes out after 2 to 5 seconds, the sensor is likely failing to send a rectification signal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I clean the 265-43232-00 flame sensor?\u003c\/strong\u003e You can temporarily restore function using a fine abrasive like steel wool, but oxidation will eventually require a full component replacement to maintain system reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWill this work with other brands?\u003c\/strong\u003e This is a specific Bradford White OEM part; always verify the model number on the rating plate before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644720140,"sku":"415-43232-00","price":91.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_af8b4e36-0e55-482b-b49c-9584c7b0d45a.png?v=1532561401"},{"product_id":"bradford-white-233-48077-03-pilot-assembly","title":"Bradford White 233-48077-03 Pilot Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-48077-03 Pilot Assembly\u003c\/strong\u003e is a high-performance \u003cstrong\u003eNatural Gas pilot burner\u003c\/strong\u003e engineered for precise ignition in residential water heaters. As a \u003cstrong\u003egenuine OEM repair part\u003c\/strong\u003e, this 19\/24 \u003cstrong\u003eHoneywell pilot assembly\u003c\/strong\u003e ensures exact fitment and maintains the factory-specified flame pattern for optimal safety and efficiency. This assembly is a critical component for \u003cstrong\u003eBradford White water heater troubleshooting\u003c\/strong\u003e, often replacing worn units in \u003cstrong\u003eRG275H\u003c\/strong\u003e and \u003cstrong\u003eLG275H\u003c\/strong\u003e series tanks to resolve pilot outage issues. The \u003cstrong\u003ethermocouple\u003c\/strong\u003e and \u003cstrong\u003epilot orifice\u003c\/strong\u003e are calibrated for \u003cstrong\u003eNatural Gas (NG)\u003c\/strong\u003e applications, providing the necessary millivolt signal to the gas control valve to maintain continuous operation. Contractors should verify the model and serial number against the \u003cstrong\u003eburner assembly\u003c\/strong\u003e specifications to ensure seamless compatibility with existing combustion chambers. Utilizing \u003cstrong\u003efactory-original parts\u003c\/strong\u003e like the \u003cstrong\u003e233-48077-03\u003c\/strong\u003e prevents the feedback loops and premature component failure often associated with low-grade aftermarket alternatives in \u003cstrong\u003eDirect Vent\u003c\/strong\u003e or standard atmospheric units.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Specifically designed for \u003cstrong\u003eBradford White water heaters\u003c\/strong\u003e, including select \u003cstrong\u003eDS series\u003c\/strong\u003e and \u003cstrong\u003eRG models\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Ignition:\u003c\/strong\u003e Features a calibrated \u003cstrong\u003epilot orifice\u003c\/strong\u003e and integrated \u003cstrong\u003ethermocouple\u003c\/strong\u003e for reliable flame sensing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to withstand high-combustion chamber temperatures without degradation of the \u003cstrong\u003epilot burner\u003c\/strong\u003e assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDrop-In Replacement:\u003c\/strong\u003e Ships in original factory packaging for verified \u003cstrong\u003eHVAC replacement part\u003c\/strong\u003e integrity and ease of installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow do I know if the 233-48077-03 is the correct part for my heater?\u003c\/strong\u003e This assembly is model-specific; check your rating plate for \u003cstrong\u003eBradford White\u003c\/strong\u003e model numbers such as \u003cstrong\u003eRG275H\u003c\/strong\u003e or \u003cstrong\u003eLG275H76\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes this work with Propane (LP) units?\u003c\/strong\u003e No, this is a dedicated \u003cstrong\u003eNatural Gas pilot assembly\u003c\/strong\u003e. Propane units require a different orifice and assembly configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I replace just the thermocouple?\u003c\/strong\u003e While possible on some models, replacing the entire \u003cstrong\u003e233-48077-03 assembly\u003c\/strong\u003e ensures all ignition components are refreshed simultaneously, reducing future service calls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35644928972,"sku":"233-48077-03","price":46.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Image_f83af80a-fe63-434d-b7ce-dbfe971cd8bd.png?v=1789095098"},{"product_id":"bradford-white-415-45653-04-pilot-assy","title":"Bradford White 415-45653-04 Pilot Assy","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-45653-04 Pilot Assy\u003c\/strong\u003e is a precision-engineered \u003cstrong\u003eLP gas pilot assembly with electrode\u003c\/strong\u003e designed for high-performance liquid propane water heaters. As a veteran-grade \u003cstrong\u003eOEM water heater repair part\u003c\/strong\u003e, this assembly ensures consistent ignition and flame sensing, which is critical for maintaining the safety and efficiency of residential heating systems. It serves as the confirmed \u003cstrong\u003edirect replacement for 233-45653-04\u003c\/strong\u003e and 233-45653-04D (Honeywell Q3451J1436), making it a vital component for technicians servicing \u003cstrong\u003eBradford White propane water heaters\u003c\/strong\u003e. The integrated electrode is optimized for rapid spark ignition, reducing startup lag and preventing unburned gas accumulation. Built to withstand high-temperature combustion environments, this \u003cstrong\u003eliquid propane pilot burner\u003c\/strong\u003e provides the reliable flame rectified signal needed for the gas valve to maintain continuous operation. Contractors should verify the heater's serial number to ensure proper fitment with specific Through-The-Wall (RG1PV, RG2PV) or residential models. This genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e ensures the system operates within original factory specifications without the risks associated with universal or generic alternatives.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Replaces legacy part numbers 233-45653-04 and 233-45653-04D for a seamless fit in Bradford White units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized for LP Gas:\u003c\/strong\u003e Specifically calibrated for liquid propane applications to ensure proper combustion and flame stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Electrode:\u003c\/strong\u003e Features a high-quality electrode for reliable spark ignition and accurate flame sensing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Engineered to resist thermal stress and oxidation in demanding residential water heating environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Restores factory-standard ignition performance, critical for the safe operation of gas-fired appliances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pilot assembly compatible with natural gas water heaters?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific assembly is designed and calibrated exclusively for \u003cstrong\u003eliquid propane (LP) gas\u003c\/strong\u003e systems. Using it in a natural gas application will result in improper combustion and potential safety hazards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this include the ignition electrode and lead wire?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 415-45653-04 includes the factory-installed electrode and the necessary hardware for a standard \u003cstrong\u003epilot assembly replacement\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is my water heater pilot not staying lit even after cleaning the assembly?\u003c\/strong\u003e\u003cbr\u003e\nCommon issues include a faulty flame sensor (electrode), a clogged pilot orifice, or a failing gas valve. Replacing the entire assembly with a genuine \u003cstrong\u003eBradford White pilot assy\u003c\/strong\u003e often resolves ignition failures caused by component wear.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645282188,"sku":"415-45653-04","price":70.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_944959c0-48b6-4655-b4d8-413f1c87868a.jpg?v=1601587334"},{"product_id":"239-46553-01","title":"Bradford White 239-46553-01 Sensor","description":"\u003cp\u003eFor contractors maintaining Bradford White water heating systems, the \u003cstrong\u003eBradford White 239-46553-01 lower temperature sensor\u003c\/strong\u003e is a critical component for ensuring optimal performance and safety. This precision-engineered \u003cstrong\u003ewater heater T-stat sensor\u003c\/strong\u003e is designed to seamlessly integrate with compatible Bradford White units, providing accurate temperature monitoring and regulation. It's essential for maintaining desired water temperature settings and preventing operational issues. When you need a reliable \u003cstrong\u003eBradford White replacement sensor\u003c\/strong\u003e, this unit offers high accuracy in temperature measurement and a robust design built to withstand typical operational stresses. Installation is straightforward, allowing for efficient system integration. Trust this \u003cstrong\u003e239-46553-01 sensor\u003c\/strong\u003e to deliver consistent, dependable temperature readings, crucial for the longevity and efficiency of the water heater.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Temperature Control:\u003c\/strong\u003e Ensures precise monitoring and regulation of water temperature for consistent performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBradford White Compatibility:\u003c\/strong\u003e Engineered specifically for seamless integration with Bradford White water heating systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to withstand demanding operational environments, promoting extended service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Designed for straightforward replacement, minimizing downtime on service calls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does a Bradford White 239-46553-01 sensor do?\u003c\/strong\u003e This sensor monitors the lower water temperature within the tank, providing critical data to the water heater's control system to maintain set temperatures and ensure safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I know if my Bradford White lower temperature sensor is faulty?\u003c\/strong\u003e Common indicators include inconsistent water temperatures, error codes on the water heater's control panel, or the unit failing to heat water adequately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the 415-46553-01 part number interchangeable with the 239-46553-01?\u003c\/strong\u003e Yes, Bradford White has updated part number prefixes; the 415-46553-01 is an identical replacement for the 239-46553-01.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645292620,"sku":"415-46553-01","price":89.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_bc274380-b135-422d-a7f8-73fdc53a0864.png?v=1547072369"},{"product_id":"bradford-white-415-48642-00-heat-element","title":"Bradford White 415-48642-00 Heat Element","description":"\u003cp\u003eReplace your compromised or scaled-out water heater elements with the \u003cstrong\u003eBradford White 415-48642-00\u003c\/strong\u003e. This \u003cstrong\u003e4500W 240V heat element\u003c\/strong\u003e is an authentic OEM replacement designed specifically for \u003cstrong\u003eBradford White electric water heaters\u003c\/strong\u003e, including high-demand residential upright and lowboy models. As a veteran-grade \u003cstrong\u003escrew-in water heater element\u003c\/strong\u003e, it features a \u003cstrong\u003ehigh watt density\u003c\/strong\u003e (HWD) copper sheath that ensures rapid thermal recovery and efficient heat transfer. This specific part is the authorized \u003cstrong\u003edirect replacement for 265-48642-00\u003c\/strong\u003e, maintaining identical fitment and electrical specifications to restore your tank to its factory performance levels. For local contractors and technicians, using genuine \u003cstrong\u003eBradford White water heater parts\u003c\/strong\u003e is critical for ensuring full compatibility with the 1-inch NPSM threads and maintaining the structural integrity of the tank seal. Always verify that your supply voltage matches the 240VAC rating before installation to prevent premature burnout of the resistor wire.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Precision:\u003c\/strong\u003e Engineered as a \u003cstrong\u003egenuine Bradford White part\u003c\/strong\u003e to ensure exact fitment and eliminate the alignment issues common with universal aftermarket elements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Recovery:\u003c\/strong\u003e Rated at \u003cstrong\u003e4500 Watts at 240 Volts\u003c\/strong\u003e, providing the high-output performance required for consistent hot water delivery in light to medium-duty applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e Direct cross-reference for the \u003cstrong\u003e265-48642-00\u003c\/strong\u003e, allowing for a seamless swap without modifications to the existing wiring or thermostat settings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Features a robust copper heating surface and premium gaskets to withstand thermal stress and resist mineral scale accumulation in hard water environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 415-48642-00 compatible with my older 265-48642-00 element?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 415-48642-00 is the official manufacturer-designated replacement. They are electrically and physically identical, designed to fit the same 1-inch screw-in ports.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing heating element in a Bradford White tank?\u003c\/strong\u003e\u003cbr\u003e\nCommon indicators include a total lack of hot water, lukewarm water due to only one element firing, or rapid \"running out\" of hot water. Technicians should perform a continuity test with a multimeter to confirm a break in the internal circuit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this 240V element work if my building only provides 208V power?\u003c\/strong\u003e\u003cbr\u003e\nWhile it will physically fit, a 240V\/4500W element operated at 208V will only produce approximately 3500W of heat. Always match the wattage and voltage to the original rating on your water heater's data plate for peak efficiency.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645488908,"sku":"415-48642-00","price":44.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Image_87c6b1b3-7bc5-4d9e-90cb-7143079f1d4a.png?v=1790195599"},{"product_id":"bradford-white-415-42034-00-thermostat","title":"Bradford White 415-42034-00 Thermostat","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-42034-00 Thermostat\u003c\/strong\u003e is a genuine OEM surface-mount temperature control designed for high-performance residential and electric utility water heaters. As a direct factory replacement for discontinued part numbers \u003cstrong\u003e265-42034-00\u003c\/strong\u003e and \u003cstrong\u003e219-40360-00\u003c\/strong\u003e, this component ensures precise thermal regulation and system safety. Engineered specifically for \u003cstrong\u003eBradford White electric water heater models\u003c\/strong\u003e, this thermostat manages heating element cycles to maintain consistent water temperatures while preventing overheating conditions. For contractors performing service on \u003cstrong\u003eMITW-10\u003c\/strong\u003e, \u003cstrong\u003eMITW40\u003c\/strong\u003e, or \u003cstrong\u003eMIITW50\u003c\/strong\u003e units, using this \u003cstrong\u003eBradford White replacement thermostat\u003c\/strong\u003e is essential for maintaining the original equipment’s listing and efficiency specifications. This \u003cstrong\u003eOEM water heater part\u003c\/strong\u003e features a heavy-duty bimetal transition and robust terminal connections to withstand the electrical loads of utility-grade applications, including \u003cstrong\u003eM-1-30U6SS\u003c\/strong\u003e and \u003cstrong\u003eTTW2\u003c\/strong\u003e series. Ensure proper contact with the tank surface during installation for accurate sensing.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits for Contractors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Specifically engineered to replace \u003cstrong\u003e415-42034-00\u003c\/strong\u003e and \u003cstrong\u003e265-42034-00\u003c\/strong\u003e without field modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Graduation:\u003c\/strong\u003e Delivers accurate temperature sensing to reduce \"stacking\" and energy waste in residential tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Model Support:\u003c\/strong\u003e Validated for use in \u003cstrong\u003eMITW\u003c\/strong\u003e, \u003cstrong\u003eMIITW\u003c\/strong\u003e, and \u003cstrong\u003eM-1\u003c\/strong\u003e series electric utility water heaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Built to manufacturer electrical specifications to ensure reliable high-limit cut-off performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Quality:\u003c\/strong\u003e Prevents the common calibration drifting associated with generic aftermarket thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the correct replacement for the 265-42034-00 thermostat?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e415-42034-00\u003c\/strong\u003e is the current, manufacturer-authorized updated version for the 265-42034-00, offering seamless fit and function.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this thermostat be used on both upper and lower heating elements?\u003c\/strong\u003e\u003cbr\u003e\nCompatibility depends on your specific model’s wiring configuration. Always verify the terminal layout and high-limit requirements against the unit’s wiring diagram before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this part work with non-Bradford White water heaters?\u003c\/strong\u003e\u003cbr\u003e\nThis is a \u003cstrong\u003egenuine Bradford White OEM part\u003c\/strong\u003e. While some surface-mount thermostats share physical dimensions, it is professionally recommended to stick to OEM components to ensure thermal accuracy and safety compliance.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645537420,"sku":"415-42034-00","price":67.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_1bfb4738-d6e0-4f7d-9506-ea3ce89b49a6.png?v=1740680902"},{"product_id":"bradford-white-239-45460-00-pressure-switch","title":"Bradford White 239-45460-00 Pressure Switch","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 239-45460-00 Pressure Switch\u003c\/strong\u003e is a critical safety component designed for \u003cstrong\u003epower vented water heaters\u003c\/strong\u003e, specifically within the Defender Safety System series. This \u003cstrong\u003eSPST (Single Pole Single Throw)\u003c\/strong\u003e switch features a precise \u003cstrong\u003e0.75\" WC (Water Column)\u003c\/strong\u003e set point, ensuring the inducer motor establishes proper draft before allowing the ignition sequence to proceed. Engineered with a \u003cstrong\u003e1\/4\" barbed\u003c\/strong\u003e vacuum connection, it monitors the differential pressure to prevent operation during venting obstructions or blower failure. When troubleshooting \u003cstrong\u003eBradford White pilot codes\u003c\/strong\u003e or ignition failure, this OEM replacement eliminates pressure fluctuations often found in generic alternatives. It is compatible with \u003cstrong\u003eRG2PV service parts\u003c\/strong\u003e and various ultra-low NOx models. Contractors should verify the \u003cstrong\u003evacuum hose\u003c\/strong\u003e integrity and \u003cstrong\u003emillivolt circuit\u003c\/strong\u003e continuity when installing this factory-authorized sensing device to restore system efficiency and safety compliance.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Precision:\u003c\/strong\u003e Guaranteed \u003cstrong\u003e0.75\" WC trip point\u003c\/strong\u003e prevents nuisance lockouts common with sub-standard universal switches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Fit:\u003c\/strong\u003e Features standard \u003cstrong\u003e1\/4 inch barbed\u003c\/strong\u003e ports and spade terminals for rapid field replacement on \u003cstrong\u003eBradford White power vent\u003c\/strong\u003e units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Ensures the \u003cstrong\u003ecombustion blower\u003c\/strong\u003e is moving sufficient air to vent flue gases safely.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e Constructed to withstand high-cycle operations in residential and commercial \u003cstrong\u003ehot water systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon HVACR Contractor Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 0.75\" WC rating signify?\u003c\/strong\u003e\u003cbr\u003e\nThis is the specific pressure threshold at which the internal diaphragm closes the electrical circuit. If the blower does not pull at least \u003cstrong\u003e0.75\" Water Column\u003c\/strong\u003e, the \u003cstrong\u003eBradford White pressure switch\u003c\/strong\u003e remains open, preventing the gas valve from energizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this switch on other water heater brands?\u003c\/strong\u003e\u003cbr\u003e\nWhile the \u003cstrong\u003eSPST contact\u003c\/strong\u003e and \u003cstrong\u003e1\/4 barbed\u003c\/strong\u003e fitting are common, the 0.75\" WC set point is calibrated specifically for \u003cstrong\u003eBradford White blower assemblies\u003c\/strong\u003e. Always match the WC rating on the part label to ensure safe \u003cstrong\u003eventilation exhaust\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes this pressure switch to fail?\u003c\/strong\u003e\u003cbr\u003e\nCommon issues include a \u003cstrong\u003eclogged vent pipe\u003c\/strong\u003e, a failing \u003cstrong\u003einducer motor\u003c\/strong\u003e, or moisture buildup in the \u003cstrong\u003evacuum tubing\u003c\/strong\u003e, all of which prevent the switch from closing the 24V or millivolt circuit.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645722188,"sku":"239-45460-00","price":209.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_31dfe0bc-9ae6-4033-abb9-444a1591e6f2.jpg?v=1617301683"},{"product_id":"265-51046-00","title":"Bradford White 265-51046-00 Tstat","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-51046-00 Tstat\u003c\/strong\u003e is a critical OEM component designed for high-performance temperature regulation in residential electric water heaters. This \u003cstrong\u003eupper and lower thermostat kit\u003c\/strong\u003e serves as the direct replacement for the \u003cstrong\u003e265-48641-00\u003c\/strong\u003e, as well as legacy parts such as the 265-46279-00 and 265-40695-00. Rated for \u003cstrong\u003e240V operation\u003c\/strong\u003e, these bimetal surface-mounted controls ensure precise thermal response and proper cycling between heating elements to prevent cold water sandwiching. The upper unit features a \u003cstrong\u003emanual high-limit safety reset\u003c\/strong\u003e (ECO) calibrated to trip if tank temperatures exceed safe operational parameters, protecting the system from dry-firing or runaway heating. For \u003cstrong\u003eHVAC contractors\u003c\/strong\u003e and plumbing professionals, this \u003cstrong\u003e240V water heater thermostat\u003c\/strong\u003e kit provides a standardized solution for restoring factory-spec performance across a wide range of Bradford White M-series models, including the M250S, M240T, and M2HE series. Replacing both the \u003cstrong\u003eupper and lower thermostats\u003c\/strong\u003e simultaneously is the industry standard to ensure balanced electrical loads and consistent temperature accuracy across the entire tank volume.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Replacement:\u003c\/strong\u003e Engineered specifically to replace the \u003cstrong\u003eBradford White 265-48641-00\u003c\/strong\u003e for perfect fitment and wiring compatibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Integrated manual reset high-limit switch prevents tank overheating and potential vessel damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Fits an extensive range of residential models including M230R, M240S, M250T, and M2HE80R.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Regulation:\u003c\/strong\u003e Precise bimetal sensing ensures accurate temperature maintenance and optimized energy consumption.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Designed for standard bracket mounting with clear terminal markings for efficient field replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this kit compatible with older 265-48641-00 models?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 265-51046-00 is the official manufacturer-designated superseding part for the 265-48641-00, offering identical electrical ratings and mounting footprints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I replace both the upper and lower thermostats at once?\u003c\/strong\u003e\u003cbr\u003e\nProfessional technicians recommend replacing both components at the same time. Because these thermostats work in tandem to cycle the heating elements, using a new upper and a worn lower can lead to inconsistent water temperatures and premature failure of the new part.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage is this thermostat kit rated for?\u003c\/strong\u003e\u003cbr\u003e\nThis kit is designed specifically for 240VAC residential electric water heater circuits and should not be used in low-voltage or gas-controlled applications.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645786252,"sku":"415-51046-00","price":63.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/bradford-white-265-51046-00-tstat-2_8c14874f-9608-4777-9038-da39e6657a84.png?v=1516063691"},{"product_id":"bradford-white-415-45543-00-ignitor","title":"Bradford White 415-45543-00 Ignitor","description":"\u003cp\u003eFor contractors maintaining Bradford White gas-fired water heaters, the \u003cstrong\u003eBradford White 415-45543-00 Ignitor\u003c\/strong\u003e is your go-to OEM replacement. This critical \u003cstrong\u003ehot surface ignitor with gasket\u003c\/strong\u003e is engineered for precise ignition of the burner flame, ensuring consistent and reliable operation. Constructed from high-temperature materials, it's built to withstand the extreme thermal demands of continuous use, providing robust performance in demanding HVACR environments. This unit is a direct replacement for the 265-45543-00, simplifying your parts inventory and ensuring seamless compatibility. The integrated gasket guarantees a proper, sealed fit, crucial for preventing gas leaks and maintaining the overall safety and efficiency of the water heater. Specifically designed for various Bradford White EF Series models, including EF60T 125\/150\/199 E\/N\/X\/A\/2 and EF100T, this \u003cstrong\u003eBradford White water heater ignitor\u003c\/strong\u003e is essential for optimal system functionality.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsures reliable ignition for gas-fired water heaters.\u003c\/li\u003e\n\u003cli\u003eConstructed with high-temperature materials for durability.\u003c\/li\u003e\n\u003cli\u003eIntegrated gasket for secure fit and leak prevention.\u003c\/li\u003e\n\u003cli\u003eMaintains optimal water heater safety and efficiency.\u003c\/li\u003e\n\u003cli\u003eDirect OEM replacement for seamless installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIs this ignitor compatible with my Bradford White EF series water heater? \u003c\/li\u003e\n\u003cli\u003eYes, it is compatible. \u003c\/li\u003e\n\u003cli\u003eWhat are the signs of a failing hot surface ignitor?\u003c\/li\u003e\n\u003cli\u003eThe primary sign of a failing hot surface ignitor (HSI) in a Bradford White EF series water heater is a failure to ignite the main burner, often accompanied by specific error codes on the unit's control display. Because these components are ceramic and operate under intense heat, they eventually crack or burn out over time.\u003c\/li\u003e\n\u003cli\u003eDoes this part include the necessary gasket for installation?\u003c\/li\u003e\n\u003cli\u003eYes it does include one gasket as shown in the picture. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645885324,"sku":"415-45543-00","price":153.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_7f4ee11b-22bd-4316-bfc0-51a1c15efa01.jpg?v=1638306145"},{"product_id":"bradford-white-239-82034-00-temperature-sensor","title":"Bradford White 239-82034-00 Temperature Sensor","description":"\u003cp\u003eFor contractors maintaining \u003cstrong\u003eBradford White water heating systems\u003c\/strong\u003e, the \u003cstrong\u003eBradford White 239-82034-00 Lower Temperature Sensor\u003c\/strong\u003e is a critical OEM component. This precision-engineered sensor is essential for accurate temperature monitoring and regulation within the water heater, ensuring both efficient operation and system safety. When troubleshooting issues like lukewarm water or diagnostic error codes indicating a sensor fault, this genuine \u003cstrong\u003eBradford White temperature sensor replacement\u003c\/strong\u003e is the correct fix. It's designed for seamless integration and robust performance in high-temperature environments, compatible with various models including the PDV80T series. Rely on this \u003cstrong\u003eOEM temperature sensor HVAC\u003c\/strong\u003e part to restore optimal functionality and consistent hot water delivery.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eAccurate temperature regulation for consistent hot water supply.\u003c\/li\u003e\n\u003cli\u003eEnsures system safety and efficient operation, preventing common faults.\u003c\/li\u003e\n\u003cli\u003eGenuine OEM component for guaranteed compatibility and reliable performance.\u003c\/li\u003e\n\u003cli\u003eDurable construction designed for extended service life in demanding water heating applications.\u003c\/li\u003e\n\u003cli\u003eResolves specific error codes related to temperature sensing, restoring proper water heater function.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhy is my Bradford White water heater producing lukewarm water?\u003c\/li\u003e\n\u003cli\u003eWhat causes a Bradford White water heater to display a temperature sensor fault code?\u003c\/li\u003e\n\u003cli\u003eIs the 239-82034-00 compatible with my Bradford White PDV series water heater?\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645923660,"sku":"239-82034-00","price":11800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_e7f98935-58d1-46c1-ae6b-85f5f1d77fe3.jpg?v=1617301544"},{"product_id":"bradford-white-415-45560-00-sensor","title":"Bradford White 415-45560-00 Sensor","description":"\u003cp\u003eFor contractors maintaining \u003cstrong\u003eBradford White water heaters\u003c\/strong\u003e, the \u003cstrong\u003e415-45560-00 Flammable Vapor Sensor\u003c\/strong\u003e is a critical OEM component. This genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e is engineered to uphold the integrity of the Flammable Vapor Ignition Resistant (FVIR) system, often referred to as the \u003cstrong\u003eDefender Safety System®\u003c\/strong\u003e. It directly supersedes part numbers 239-45560-00 and 265-45560-00, ensuring seamless integration and precise functionality. Designed to detect the presence of flammable vapors, this sensor prevents hazardous conditions and system lockouts, which is vital for residential water heater applications. Proper installation by a qualified technician ensures your unit operates safely and in compliance with manufacturer specifications, protecting the overall system and extending equipment life.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Flammable Vapor Detection:\u003c\/strong\u003e Safeguards the water heating system by identifying hazardous vapor presence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine OEM Replacement:\u003c\/strong\u003e Ensures precise fit, form, and function, maintaining system design specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Compatibility:\u003c\/strong\u003e Replaces older part numbers 239-45560-00 and 265-45560-00 for straightforward servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Safety Compliance:\u003c\/strong\u003e Essential for the continued operation of the Bradford White Defender Safety System®.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced System Reliability:\u003c\/strong\u003e Contributes to the long-term, dependable performance of the water heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 415-45560-00 sensor?\u003c\/strong\u003e\u003cbr\u003e\nThis sensor is a key component of your Bradford White water heater's Flammable Vapor Ignition Resistant (FVIR) system, designed to detect flammable vapors in the surrounding environment and prevent ignition, ensuring safe operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this sensor compatible with my Bradford White water heater?\u003c\/strong\u003e\u003cbr\u003e\nThe 415-45560-00 is an OEM replacement for specific Bradford White residential gas water heaters, including models within the Defender Safety System, PE2XR504T, PE4403S, PE440T, and PE4503 series. Always verify compatibility with your unit's specific model and serial number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhen should the flammable vapor sensor be replaced?\u003c\/strong\u003e\u003cbr\u003e\nManufacturers recommend replacing the sensor if it has been exposed to flammable vapors, as its detection capabilities may be compromised. It should also be replaced if diagnostics indicate a malfunction or if the water heater enters a permanent lockout state due to a sensor fault.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I reset the 415-45560-00 sensor after a lockout?\u003c\/strong\u003e\u003cbr\u003e\nWhile some systems allow for a temporary reset, if the sensor has tripped due to actual vapor detection, it is strongly recommended to replace it. A reset may only temporarily clear the error, and the sensor may not function at full capacity afterward, leading to future lockouts and potential safety risks.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35645935692,"sku":"415-45560-00","price":95.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_859c9c40-a077-48ca-82b8-f7522c28e6e1.png?v=1757369823"},{"product_id":"bradford-white-239-82033-00-temperature-sensor","title":"Bradford White 239-82033-00 Temperature Sensor","description":"\u003cp\u003eFor contractors maintaining Bradford White water heater systems, the \u003cstrong\u003eBradford White 239-82033-00 Upper Temperature Sensor\u003c\/strong\u003e is a critical OEM component. This sensor, also cross-referenced as 415-82033-00 or Honeywell 207762A, is engineered to provide precise temperature monitoring within the upper tank section. Essential for accurate water temperature regulation and system safety, it ensures your installations operate efficiently and reliably. A faulty \u003cstrong\u003ewater heater thermostat sensor\u003c\/strong\u003e can lead to insufficient hot water, overheating, or trigger diagnostic codes, such as the common five-flash error indicating a \u003cstrong\u003etemperature sensor fault\u003c\/strong\u003e. This genuine \u003cstrong\u003eBradford White water heater sensor\u003c\/strong\u003e is designed for direct compatibility with various Bradford White commercial gas water heater models, including D65T370, D65T399, D75T300, D80L399, and PDV80T199\/300\/E, ensuring seamless integration and restoring optimal performance.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003eRestores accurate water temperature regulation.\u003c\/li\u003e\n  \u003cli\u003eEnsures proper water heater operation and safety.\u003c\/li\u003e\n  \u003cli\u003eDirect OEM fitment for specified Bradford White models.\u003c\/li\u003e\n  \u003cli\u003eHelps prevent common error codes related to temperature sensing.\u003c\/li\u003e\n  \u003cli\u003eCritical for maintaining system efficiency and longevity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are common indicators of a failing upper temperature sensor?\u003c\/strong\u003e\u003cbr\u003e\nA: Common signs include inconsistent water temperature, no hot water, or diagnostic error codes (e.g., five flashes on the control panel) indicating a sensor malfunction.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is this 239-82033-00 replacement part compatible with all Bradford White water heaters?\u003c\/strong\u003e\u003cbr\u003e\nA: This sensor is designed for specific Bradford White commercial gas water heater models. Always verify compatibility with your unit's model and serial number to ensure correct fitment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can a faulty temperature sensor cause my water heater to stop heating entirely?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes, if the upper temperature sensor fails or trips, especially in FVIR systems, it can prevent the water heater from heating water, leading to a complete loss of hot water.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35646029900,"sku":"415-82033-00","price":85.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_6eaa1198-854e-42ab-af5f-ff7896bc7105.jpg?v=1617300983"},{"product_id":"233-46670-00","title":"Bradford White 233-46670-00 Thermopile","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-46670-00\u003c\/strong\u003e is an OEM \u003cstrong\u003e750mv thermopile\u003c\/strong\u003e designed for high-recovery commercial and residential gas water heaters. This \u003cstrong\u003epilot generator\u003c\/strong\u003e features a \u003cstrong\u003e2-wire lead\u003c\/strong\u003e configuration and is a direct, identical replacement for the \u003cstrong\u003eHoneywell Q313A1247\u003c\/strong\u003e. In the field, this component is critical for generating the millivoltage required to power the electromagnetic coil in the gas control valve without an external power source. When troubleshooting \u003cstrong\u003ewater heater pilot lights\u003c\/strong\u003e that fail to stay lit or produce insufficient millivoltage, this \u003cstrong\u003ethermopile replacement\u003c\/strong\u003e ensures stable millivolt output and reliable gas valve actuation. Built for durability in high-heat environments, the \u003cstrong\u003e233-46670-00\u003c\/strong\u003e maintains the integrity of the \u003cstrong\u003epilot assembly\u003c\/strong\u003e, preventing nuisance outages and ensuring consistent burner ignition. For technicians, using this \u003cstrong\u003eBradford White 233-46670-00 thermopile\u003c\/strong\u003e ensures exact fitment and electrical compatibility, meeting original equipment specifications for safety and performance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Functions as a direct cross-reference for the \u003cstrong\u003eHoneywell Q313A1247\u003c\/strong\u003e, ensuring seamless integration with existing gas valves.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimal Millivolt Output:\u003c\/strong\u003e Engineered to provide a consistent \u003cstrong\u003e750mv signal\u003c\/strong\u003e to ensure the gas safety valve opens and stays open during operation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Designed with high-temperature lead insulation to withstand the thermal stress common in \u003cstrong\u003estanding pilot systems\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e The \u003cstrong\u003e2-wire lead\u003c\/strong\u003e design uses standard spade terminals for quick connection to the terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I test the Bradford White 233-46670-00 using a multimeter?\u003c\/strong\u003e\u003cbr\u003e\nSet your multimeter to the DC millivolt scale. Check the open-circuit voltage by connecting the leads to the thermopile wires while the pilot is burning. You should see a reading between 650mv and 850mv. If the reading is below 400mv under load, the component requires replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this thermopile work with LP (Propane) and Natural Gas units?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003e750mv pilot generator\u003c\/strong\u003e is compatible with both fuel types, provided the pilot burner orifice is correctly sized for the specific gas being used.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes a 2-wire thermopile to fail prematurely?\u003c\/strong\u003e\u003cbr\u003e\nThe most common causes are carbon buildup on the element, improper pilot flame impingement, or excessive heat at the wire junction. Ensure the pilot flame envelopes the top 1\/2 to 1 inch of the thermopile tip for maximum longevity.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35646358476,"sku":"415-46670-00","price":85.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_fa32bc1a-092a-42ff-b486-8246d3a854ab.png?v=1570057472"},{"product_id":"bradford-white-415-46481-00-spark-rod","title":"Bradford White 415-46481-00 Spark Rod","description":"\u003cp\u003eFor contractors and technicians maintaining Bradford White gas-fired water heaters, the \u003cstrong\u003eBradford White 415-46481-00 Spark Rod\u003c\/strong\u003e is an essential OEM replacement component. This spark rod, which directly supersedes part number 265-46481-00, is engineered to ensure reliable ignition in compatible units, including models like EF160T120(EN, SX) and EF100T150(E)(N, X)(A)2. It functions by generating a high-voltage spark with a nominal 0.22-inch gap to the burner surface, initiating the combustion process. A faulty \u003cstrong\u003eBradford White water heater igniter\u003c\/strong\u003e can lead to intermittent heating or complete ignition failure, making this genuine \u003cstrong\u003egas water heater spark electrode\u003c\/strong\u003e critical for restoring optimal performance and consistent hot water delivery. Always verify compatibility with your specific Bradford White unit to ensure proper fitment and operation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eEnsures reliable ignition for gas-fired water heaters.\u003c\/li\u003e\n    \u003cli\u003eGenuine \u003cstrong\u003eBradford White OEM parts\u003c\/strong\u003e for precise fit and function.\u003c\/li\u003e\n    \u003cli\u003eIncludes gasket for a secure, leak-free installation.\u003c\/li\u003e\n    \u003cli\u003eRestores efficient operation and consistent hot water supply.\u003c\/li\u003e\n    \u003cli\u003eDirect replacement for older part number 265-46481-00.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eWhy is my water heater not igniting? (Often due to a faulty spark rod or gas supply issues.)\u003c\/li\u003e\n    \u003cli\u003eHow do I know if my spark rod is faulty? (Symptoms include clicking sounds without ignition, intermittent heating, or no hot water.)\u003c\/li\u003e\n    \u003cli\u003eIs this spark rod compatible with my Bradford White water heater? (Verify your model number against the listed compatible units, such as EF160T120(EN, SX) and EF100T150(E)(N, X)(A)2.)\u003c\/li\u003e\n    \u003cli\u003eWhat is the correct gap for a spark rod? (The nominal gap to the burner surface is 0.22 inches.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35646870156,"sku":"415-46481-00","price":83.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_033ac122-ad3e-4977-bfa0-c67e26a756ce.jpg?v=1627428614"},{"product_id":"bradford-white-233-45515-00-pilot-assembly","title":"Bradford White 233-45515-00 Pilot Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-45515-00 Pilot Assembly\u003c\/strong\u003e is a critical OEM component for restoring the pilot burner and ignition sequence in residential natural gas water heaters. As a direct \u003cstrong\u003e233-40876-02 replacement\u003c\/strong\u003e, this assembly simplifies field repairs by ensuring exact mechanical fitment and millivolt output compatibility. Designed for \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e models, it features a high-grade thermopile\/thermocouple integration that provides reliable flame sensing to the gas control valve. This specific \u003cstrong\u003ewater heater pilot assembly\u003c\/strong\u003e is engineered to withstand high combustion chamber temperatures while maintaining consistent spark-to-pilot ignition. For contractors managing \u003cstrong\u003eBradford White water heater parts\u003c\/strong\u003e replacement, utilizing this genuine assembly prevents common nuisance lockouts and pilot outages caused by carbon buildup or worn-out sensor probes. Proper installation ensures the furnace-brazed connections and orifice alignment meet factory specifications for optimal thermal efficiency and gas flow regulation.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits for Contractors\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect OEM Fit:\u003c\/strong\u003e Ensures seamless integration with the existing gas manifold and burner rack without field modifications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced Reliability:\u003c\/strong\u003e Designed specifically for the \u003cstrong\u003eBradford White Defender Series\u003c\/strong\u003e to resolve recurring pilot outages.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eComplete Assembly:\u003c\/strong\u003e Includes the pilot tube, electrode, and sensing element to streamline the maintenance process.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Millivolt Output:\u003c\/strong\u003e Provides a stable signal to the burner control for precise gas flow management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Technical Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a pilot that will not stay lit on a Bradford White unit?\u003c\/strong\u003e\u003cbr\u003e\nFirst, inspect the \u003cstrong\u003ethermopile output\u003c\/strong\u003e and check for manifold pressure drops. If the thermopile is failing to generate sufficient millivolts, replacing the entire 233-45515-00 assembly is the standard procedure to restore the thermocouple signal and gas valve hold-in circuit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 233-45515-00 compatible with older 233-40876-02 models?\u003c\/strong\u003e\u003cbr\u003e\nYes, this is the official manufacturer-designated superseded part number. It is built to the same specifications and replaces the legacy pilot burner assembly found in many \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes pilot assembly failure in high-efficiency atmospheric units?\u003c\/strong\u003e\u003cbr\u003e\nCommon failure points include scorched thermopiles, clogged orifices from gas impurities, or damaged ceramic insulators on the electrode. Replacing the assembly ensures clean ignition and accurate flame rectification.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35646960140,"sku":"233-45515-00","price":143.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_aae28dd2-a901-45af-8098-b99616082b0c.jpg?v=1646093745"},{"product_id":"bradford-white-265-47439-04-32-burner","title":"Bradford White 265-47439-04-32 Burner","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-47439-04-32 Natural Gas Complete Burner\u003c\/strong\u003e is a precision-engineered replacement assembly designed for high-recovery commercial and residential atmospheric water heaters. This \u003cstrong\u003enatural gas burner assembly\u003c\/strong\u003e features a robust stainless steel construction to resist thermal fatigue and ensure consistent flame patterns across the manifold. It is engineered for specific \u003cstrong\u003eBradford White Defender Safety System\u003c\/strong\u003e models, maintaining the necessary manifold pressure for optimal BTU output. When replacing a \u003cstrong\u003ewater heater burner assembly\u003c\/strong\u003e, verifying the orifice size and venturi alignment is critical for preventing resonance and ensuring complete combustion. This genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e serves as a direct drop-in for worn or scaled burner trays, restoring the thermal efficiency of the appliance. Technicians should prioritize this \u003cstrong\u003eOEM burner assembly\u003c\/strong\u003e to ensure exact fitment with existing gas valves and pilot assemblies, maintaining the integrity of the original combustion chamber design and airflow requirements.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Ensures seamless integration with the \u003cstrong\u003eBradford White 265-47439-04-32\u003c\/strong\u003e specification for calibrated gas flow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e High-grade materials prevent warping and port blockage under high-cycle environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Combustion:\u003c\/strong\u003e Precision-drilled ports provide a stable flame, reducing carbon buildup and maximizing heat transfer.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Complete assembly reduces labor time in the field compared to individual component replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this burner assembly compatible with LP propane units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific assembly is calibrated for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e only. Using this on liquid propane units will cause hazardous combustion conditions due to incorrect orifice sizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhen should a technician replace the entire burner tray instead of just cleaning it?\u003c\/strong\u003e\u003cbr\u003e\nIf there is evidence of heavy oxidation, enlarged burner ports, or warping that affects the flame envelope, a full assembly replacement is required to maintain safety standards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this assembly include the pilot and thermocouple?\u003c\/strong\u003e\u003cbr\u003e\nThis part number refers to the \u003cstrong\u003ecomplete burner\u003c\/strong\u003e tray and manifold; however, technicians should verify if the specific application requires a separate pilot assembly based on the heater's serial number.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35647162252,"sku":"265-47439-04-32","price":182.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/2_2c53b2fd-37b7-4789-a84d-ef13934550a3.png?v=1503962305"},{"product_id":"bradford-white-415-40918-00-ignitor-kit","title":"Bradford White 415-40918-00 Ignitor Kit","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-40918-00 Ignitor Kit\u003c\/strong\u003e is a critical OEM component designed for high-performance ignition sequences in residential and commercial water heaters. This kit serves as the direct engineered replacement for the legacy \u003cstrong\u003e239-40918-00 ignitor\u003c\/strong\u003e, ensuring seamless integration with existing burner assemblies. Manufactured to handle high-amperage draw and frequent cycling, the silicon carbide element provides a stable heat source to energize the main burner without the risk of delayed ignition. The inclusion of a high-temperature gasket ensures a \u003cstrong\u003ehermetic seal\u003c\/strong\u003e at the combustion chamber interface, preventing gas leaks and maintaining vacuum integrity during the \u003cstrong\u003ehot surface ignition (HSI)\u003c\/strong\u003e process. For technicians troubleshooting a lockout or \u003cstrong\u003eintermittent ignition failure\u003c\/strong\u003e, this kit restores reliable flame rectification and signal feedback to the control board. Every kit is spec-matched to 40,000 to 50,000 BTU atmospheric vents and power-vented units to maintain factory combustion efficiency and safety standards.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Fitment:\u003c\/strong\u003e Replaces \u003cstrong\u003epart number 239-40918-00\u003c\/strong\u003e with exact lead length and terminal connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Installation Kit:\u003c\/strong\u003e Includes the requisite \u003cstrong\u003ecombustion chamber gasket\u003c\/strong\u003e to prevent carbon monoxide leakage and heat loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Durability:\u003c\/strong\u003e Constructed with industrial-grade materials to resist oxidation and thermal shock in high-heat environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCritical Safety Compliance:\u003c\/strong\u003e Restores factory-specified \u003cstrong\u003ehot surface ignition\u003c\/strong\u003e timing for safe burner startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 415-40918-00 compatible with older Bradford White models?\u003c\/strong\u003e\u003cbr\u003e\nYes, this is the official manufacturer-designated \u003cstrong\u003ereplacement ignitor\u003c\/strong\u003e for models previously utilizing the 239-40918-00 part number. Always verify your model and serial number before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is the gasket included in this kit?\u003c\/strong\u003e\u003cbr\u003e\nOpening the combustion chamber breaks the original seal. Replacing the \u003cstrong\u003eignitor gasket\u003c\/strong\u003e is mandatory to maintain structural integrity and prevent dangerous exhaust leakage into the surrounding area.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I touch the ignitor element during installation?\u003c\/strong\u003e\u003cbr\u003e\nNo. Like all \u003cstrong\u003ewater heater ignitor replacements\u003c\/strong\u003e, skin oils can create hotspots on the element, leading to premature failure. Handle the component by the ceramic base only.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35647780812,"sku":"415-40918-00","price":158.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_89add55a-9b9b-40c8-9973-f598cad6580a.png?v=1701281939"},{"product_id":"bradford-white-415-45653-05-pilot-assembly","title":"Bradford White 415-45653-05 Pilot Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-45653-05 Pilot Assembly\u003c\/strong\u003e is a critical \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e engineered specifically for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e utilizing the \u003cstrong\u003eHoneywell Icon System\u003c\/strong\u003e. This \u003cstrong\u003egenuine pilot assembly\u003c\/strong\u003e features an integrated electrode and pilot burner designed to maintain precise flame rectification and reliable ignition cycles in high-performance residential units. As the direct successor to the \u003cstrong\u003e233-45653-05\u003c\/strong\u003e, this component ensures seamless compatibility with \u003cstrong\u003ePower Vent\u003c\/strong\u003e and \u003cstrong\u003ePower Direct Vent\u003c\/strong\u003e models, including the PE2XR and PE4403SF series. For technicians, this assembly simplifies field repairs by including the necessary \u003cstrong\u003ethermopile\u003c\/strong\u003e and \u003cstrong\u003eigniter electrode\u003c\/strong\u003e connections required to resolve \u003cstrong\u003ewater heater lockout\u003c\/strong\u003e issues or inconsistent pilot signals. Using \u003cstrong\u003egenuine Bradford White parts\u003c\/strong\u003e preserves the original equipment's combustion parameters and safety certifications, preventing common integration failures associated with generic aftermarket alternatives. Ensure the orifice and shroud are clear of debris during installation to optimize the \u003cstrong\u003epilot flame\u003c\/strong\u003e pattern for the main burner transition.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Replacement:\u003c\/strong\u003e Replaces deprecated part numbers \u003cstrong\u003e233-45653-05\u003c\/strong\u003e, 233-45653-01, and 233-45653-02 without cabinet modification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Ignition:\u003c\/strong\u003e Features a factory-set \u003cstrong\u003eelectrode\u003c\/strong\u003e gap for consistent sparking and rapid response within \u003cstrong\u003eHoneywell Natural Gas\u003c\/strong\u003e control systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Specifically designed for \u003cstrong\u003eBradford White M1TW\u003c\/strong\u003e and \u003cstrong\u003ePower Vent\u003c\/strong\u003e series heaters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Sensing:\u003c\/strong\u003e Provides accurate millivolt output to the gas valve to prevent nuisance shutdowns during high-demand cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pilot assembly compatible with propane (LP) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, the 415-45653-05 is strictly for \u003cstrong\u003eNatural Gas pilot assembly\u003c\/strong\u003e applications. Using this in an LP system will cause unsafe combustion and equipment failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat was the 233-45653-05?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003e233-45653-05\u003c\/strong\u003e was the original factory-installed assembly. The 415-45653-05 is the current \u003cstrong\u003eservice replacement\u003c\/strong\u003e part that provides the same technical specifications and fitment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this include the electrode and mounting hardware?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003eNAT GAS PILOT ASSY W\/ELECTROD\u003c\/strong\u003e includes the pilot burner, electrode, and integrated lead wires required for a standard field replacement.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35647893388,"sku":"415-45653-05","price":54.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_774a1016-fa03-4c33-859e-eb929d037255.png?v=1700518767"},{"product_id":"bradford-white-233-41347-00-board","title":"Bradford White 233-41347-00 Board","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-41347-00 PC Thermostat Board\u003c\/strong\u003e is a critical replacement component designed for precise temperature regulation and ignition control in high-efficiency water heaters. This \u003cstrong\u003eOEM water heater control board\u003c\/strong\u003e serves as the central processing unit for system communication, monitoring thermal sensor data and managing \u003cstrong\u003egas valve modulation\u003c\/strong\u003e. Engineered for a direct fit, it simplifies field service and minimizes downtime by ensuring stable signal processing and burner cycles. This \u003cstrong\u003eBradford White replacement PCB\u003c\/strong\u003e is built to withstand the thermal stressors common in residential and light commercial plumbing environments, prioritizing accurate thermistor feedback and flame rectification. Integrating this genuine \u003cstrong\u003eelectronic control board\u003c\/strong\u003e maintains the factory-calibrated safety protocols and operational efficiency of the unit. For contractors managing diagnostic service calls, this authorized \u003cstrong\u003ethermostat circuit board\u003c\/strong\u003e is the standard solution for resolving intermittent heating issues or sequence-of-operation failures within compatible Bradford White models.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Control:\u003c\/strong\u003e Provides accurate temperature monitoring to prevent stacking and ensure consistent delivery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Exact replacement for the 233-41347-00, ensuring seamless integration with existing wire harnesses and sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e Integrated circuitry assists in maintaining proper communication between the thermostat and firing controls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to technical specifications for high-heat environments to prevent premature component soldering fatigue.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the signs that a 233-41347-00 board has failed?\u003c\/strong\u003e\u003cbr\u003e\nCommon symptoms include the burner failing to ignite despite a call for heat, erratic temperature fluctuations, or specific status codes on the diagnostic interface indicating a control system error.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this control board compatible with power-vented units?\u003c\/strong\u003e\u003cbr\u003e\nCompatibility depends on the specific serial and model number of your appliance. This board is typically utilized in specific PC-series configurations; always cross-reference the parts list for your specific water heater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board include the diagnostic LED indicators?\u003c\/strong\u003e\u003cbr\u003e\nYes, this OEM board features onboard signal processing and diagnostic indicators to assist technicians in troubleshooting the ignition sequence and sensor status.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35647963916,"sku":"233-41347-00","price":168.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_66e6d0a6-2b73-4a6f-bf43-b06a2f7e0a16.jpg?v=1593721777"},{"product_id":"bradford-white-265-46181-01-gas-valve","title":"Bradford White 265-46181-01 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-46181-01 Gas Valve\u003c\/strong\u003e is an OEM \u003cstrong\u003enatural gas water heater control valve\u003c\/strong\u003e designed specifically for the ICON System. This \u003cstrong\u003enatural gas thermostat control\u003c\/strong\u003e features an integrated piezo igniter and high-limit temperature sensor (ECO) to ensure precise thermal regulation and safety during combustion cycles. Engineering specifications for the \u003cstrong\u003e265-46181-01\u003c\/strong\u003e include a standard 1\/2-inch NPT inlet and 1\/2-inch inverted flare outlet, common in Defender Safety System models. As a direct \u003cstrong\u003eHoneywell water heater valve replacement\u003c\/strong\u003e, this component manages the pilot assembly gas flow and main burner orifice pressure. Techs should note the thermopile-generated millivolt signal requirement for the diagnostic LED indicator. This \u003cstrong\u003eBradford White ICON system valve\u003c\/strong\u003e is essential for resolving lockout codes and erratic pilot outages on atmospheric vent units. Ensure the shank length matches the tank insulation depth for proper seating and leak-free installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOEM \u003cstrong\u003eBradford White 265-46181-01\u003c\/strong\u003e ensures direct-fit compatibility without manifold modification.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eICON System intelligence\u003c\/strong\u003e provides advanced diagnostic capabilities via LED blink codes.\u003c\/li\u003e\n\u003cli\u003eRobust internal \u003cstrong\u003egas pressure regulator\u003c\/strong\u003e maintains consistent manifold pressure for clean combustion.\u003c\/li\u003e\n\u003cli\u003eIncludes factory-installed piezo igniter for reliable pilot sparking without external power.\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cstrong\u003eenergy cut-off (ECO)\u003c\/strong\u003e sensor prevents overheating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot the LED blink codes on this valve?\u003c\/strong\u003e\u003cbr\u003eThe diagnostic LED on the \u003cstrong\u003eBradford White gas control\u003c\/strong\u003e indicates specific faults, such as thermopile voltage issues or sensor failures; refer to the side-panel chart for the exact flash sequence meaning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this valve compatible with LP\/Propane units?\u003c\/strong\u003e\u003cbr\u003eNo, the \u003cstrong\u003e265-46181-01\u003c\/strong\u003e is calibrated strictly for \u003cstrong\u003enatural gas water heater\u003c\/strong\u003e applications and must not be used for liquid propane conversions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary cause of pilot failure on these units?\u003c\/strong\u003e\u003cbr\u003ePilot outages are often caused by a weak thermopile signal or a clogged pilot orifice; verify that the \u003cstrong\u003enatural gas valve\u003c\/strong\u003e receives at least 350mV from the pilot assembly.\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e265-46181-01 is the cross for 100170634\u003c\/span\u003e\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650548876,"sku":"265-46181-01","price":238.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_160dacbc-9316-41f8-958e-661d3e8f2446.jpg?v=1625246426"},{"product_id":"bradford-white-265-46181-03-gas-valve","title":"Bradford White 265-46181-03 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-46181-03 Gas Valve\u003c\/strong\u003e is a direct replacement \u003cstrong\u003enatural gas water heater control valve\u003c\/strong\u003e designed for specific atmospheric vent models. This \u003cstrong\u003eRobertshaw-built gas control\u003c\/strong\u003e features a \u003cstrong\u003e4\" WC manifold pressure\u003c\/strong\u003e setting and standard \u003cstrong\u003e1\/2\" NPT connections\u003c\/strong\u003e, ensuring a precise interface with existing burner manifolds. Built for high-reliability service, the thermoplastic body houses an integrated \u003cstrong\u003ethermostat and safety shut-off\u003c\/strong\u003e mechanism. It is critical for technicians to verify the \u003cstrong\u003epart number compatibility\u003c\/strong\u003e against the water heater rating plate, as this valve is calibrated specifically for \u003cstrong\u003enatural gas (NG) applications\u003c\/strong\u003e and should not be used for LP conversions. The \u003cstrong\u003ethermal well immersion depth\u003c\/strong\u003e and \u003cstrong\u003ethermopile output requirements\u003c\/strong\u003e are engineered to match original equipment manufacturer (OEM) specifications, maintaining the combustion system's integrity and efficiency. This \u003cstrong\u003ehot water heater gas valve\u003c\/strong\u003e is essential for resolving pilot lighting failures or erratic temperature regulation in residential tanks.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Contractors\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM-Spec Calibration:\u003c\/strong\u003e Factory-set at \u003cstrong\u003e4.0\" Water Column\u003c\/strong\u003e to ensure consistent burner pressure and manifold performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated High-Limit:\u003c\/strong\u003e Features a built-in \u003cstrong\u003eEnergy Cut-Off (ECO)\u003c\/strong\u003e sensor to prevent overheating conditions during operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandardized Fittings:\u003c\/strong\u003e Utilizes \u003cstrong\u003e1\/2\" NPT inlet and outlet\u003c\/strong\u003e ports for seamless integration with rigid pipe or CSST connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Thermostat Sensing:\u003c\/strong\u003e Heavy-duty immersion element provides accurate temperature feedback for tighter cycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Bradford White 265-46181-03 compatible with LP units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific model is factory-calibrated for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e only. Using this on propane units creates a significant safety risk due to incorrect orifice pressure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing 265-46181-03 valve?\u003c\/strong\u003e\u003cbr\u003e\nCommon indicators include the \u003cstrong\u003epilot light not staying lit\u003c\/strong\u003e, the main burner failing to ignite despite a verified thermocouple\/thermopile signal, or the tank failing to reach the set temperature.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this include the thermal well?\u003c\/strong\u003e\u003cbr\u003e\nThis component typically features an integrated shank for direct immersion into the tank; always verify if your specific installation requires a separate flange based on the tank's age.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650588940,"sku":"265-46181-03","price":238.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_c5d201f9-a9bd-4bad-aa08-8b4422df8009.jpg?v=1625245979"},{"product_id":"bradford-white-265-45114-02-conversion-kit","title":"Bradford White 265-45114-02 Conversion Kit","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-45114-02 LP Gas Solenoid Conversion Kit\u003c\/strong\u003e is a critical service component designed for high-efficiency \u003cstrong\u003epower vented gas water heaters\u003c\/strong\u003e. This specialized \u003cstrong\u003eLP gas conversion kit\u003c\/strong\u003e allows for the precise transition of fuel sources while maintaining the integrity of the \u003cstrong\u003ecombustion system\u003c\/strong\u003e. Engineered specifically for the \u003cstrong\u003eBradford White 239-45114-02 solenoid valve\u003c\/strong\u003e, this kit ensures the \u003cstrong\u003emanifold pressure\u003c\/strong\u003e is correctly regulated for propane applications. As a technician, ensuring the proper \u003cstrong\u003eorifice size\u003c\/strong\u003e and spring tension within the \u003cstrong\u003esolenoid assembly\u003c\/strong\u003e is paramount for preventing carbon buildup and ensuring steady \u003cstrong\u003eBTU output\u003c\/strong\u003e. This kit facilitates a reliable \u003cstrong\u003efuel conversion\u003c\/strong\u003e, ensuring the flame sensor and ignition system interact seamlessly with the modified gas flow. By replacing the internal components with this \u003cstrong\u003eOEM water heater part\u003c\/strong\u003e, you maintain the 100% safety shutoff functionality required for high-recovery residential modules.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise \u003cstrong\u003emanifold pressure regulation\u003c\/strong\u003e for liquid propane transitions.\u003c\/li\u003e\n  \u003cli\u003eIncludes the specific \u003cstrong\u003esolenoid spring and orifice\u003c\/strong\u003e required for high-efficiency burner patterns.\u003c\/li\u003e\n  \u003cli\u003eDesigned for direct compatibility with \u003cstrong\u003epower vented solenoid gas valves\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eFacilitates a cleaner burn, reducing service calls for \u003cstrong\u003esooting or flame failure\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eMaintains the original \u003cstrong\u003eUL\/CSA certification\u003c\/strong\u003e of the heating appliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Service Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this kit compatible with standard atmospheric vent heaters?\u003c\/strong\u003e\u003cbr\u003eNo, this kit is engineered for specific \u003cstrong\u003epower vent models\u003c\/strong\u003e utilizing the 45114 series solenoid valve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a manometer for this installation?\u003c\/strong\u003e\u003cbr\u003eYes, verifying the \u003cstrong\u003eLP manifold pressure\u003c\/strong\u003e after installing the conversion kit is essential for safe operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this include the replacement pilot orifice?\u003c\/strong\u003e\u003cbr\u003eThis kit focus on the \u003cstrong\u003emain burner solenoid conversion\u003c\/strong\u003e; always check the specific manifold assembly to determine if pilot modifications are required.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650618252,"sku":"265-45114-02","price":176.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_4f6fcb02-9e8c-4d98-a292-1e42bb59181d.jpg?v=1629328140"},{"product_id":"bradford-white-265-46181-02-gas-valve","title":"Bradford White 265-46181-02 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-46181-02\u003c\/strong\u003e is a direct replacement \u003cstrong\u003enatural gas water heater control valve\u003c\/strong\u003e designed specifically for the \u003cstrong\u003eIcon System\u003c\/strong\u003e. This \u003cstrong\u003e4-inch WC natural gas valve\u003c\/strong\u003e features a \u003cstrong\u003e1\/2-inch NPT inlet\u003c\/strong\u003e and provides precise thermostatic control for residential and light commercial water heaters. Engineers designed this unit with a \u003cstrong\u003epiezoelectric igniter\u003c\/strong\u003e and an integrated \u003cstrong\u003ehigh-limit energy cutoff (ECO)\u003c\/strong\u003e to ensure safe operation. When troubleshooting a \u003cstrong\u003ewater heater pilot that won't stay lit\u003c\/strong\u003e, this manifold gas valve assembly is often the required fix for faulty internal sensors or millivolt signal failures. It regulates gas flow at a standard \u003cstrong\u003e4.0\" Water Column\u003c\/strong\u003e pressure, maintaining optimal burner efficiency. As a genuine \u003cstrong\u003eOEM Bradford White part\u003c\/strong\u003e, it ensures 100% compatibility with specific Defender Safety System models, eliminating the flange alignment issues common with aftermarket universal valves.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Pressure Regulation:\u003c\/strong\u003e Factory-calibrated to \u003cstrong\u003e4\" WC\u003c\/strong\u003e for stable Natural Gas combustion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Fit Replacement:\u003c\/strong\u003e Features a \u003cstrong\u003e1\/2\" gas connection\u003c\/strong\u003e, minimizing downtime during field repairs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e The \u003cstrong\u003eBradford White Icon System gas valve\u003c\/strong\u003e utilizes a status light to assist in rapid error-code identification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Built-in \u003cstrong\u003ethermopile-powered control\u003c\/strong\u003e requires no external power source while maintaining a reliable thermocouple circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 265-46181-02 compatible with Propane (LP) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific part is calibrated for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e at 4\" WC. Using this on an LP system will cause dangerous over-firing and equipment damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing Bradford White Icon gas valve?\u003c\/strong\u003e\u003cbr\u003e\nCommon indicators include a \u003cstrong\u003eflashing status light\u003c\/strong\u003e, the burner failing to ignite despite a lit pilot, or the \u003cstrong\u003epiezo igniter\u003c\/strong\u003e failing to create a spark during the lighting sequence.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I replace the internal thermostat without replacing the whole valve?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eIcon System gas control\u003c\/strong\u003e is a sealed unit; if the internal sensor or solenoid fails, the entire manifold assembly must be replaced to maintain ANSI safety standards.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650726284,"sku":"265-46181-02","price":251.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_66c72966-c675-4f55-b109-5dc15f453e9f.jpg?v=1625246142"},{"product_id":"bradford-white-265-46289-01-pilot-assembly","title":"Bradford White 265-46289-01 Pilot Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-46289-01 Pilot Assembly\u003c\/strong\u003e is a critical OEM replacement component designed for \u003cstrong\u003eNatural Gas water heaters\u003c\/strong\u003e utilizing the \u003cstrong\u003eIcon System gas valve\u003c\/strong\u003e. This \u003cstrong\u003edirect replacement pilot assembly\u003c\/strong\u003e ensures reliable ignition and consistent flame sensing for residential and commercial units. As a veteran-grade \u003cstrong\u003epilot burner assembly with thermopile\u003c\/strong\u003e, it features high-grade construction to withstand standard combustion chamber temperatures without premature oxidation. The unit includes the integrated \u003cstrong\u003ethermopile generator\u003c\/strong\u003e, high-voltage electrode, and pre-formed \u003cstrong\u003epilot tubing\u003c\/strong\u003e for precise fitment during field installation. When troubleshooting erratic pilot behavior or thermocouple signal dropout, replacing the entire assembly ensures the \u003cstrong\u003epilot orifice\u003c\/strong\u003e and electrode gap are within factory specifications. This \u003cstrong\u003eHVAC replacement part\u003c\/strong\u003e is engineered for seamless mechanical compatibility with Bradford White's \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e models, maintaining the integrity of the sealed combustion system. Always verify the manifold pressure and inspect the burner tray for debris during installation to ensure optimal performance.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Direct-fit for \u003cstrong\u003eBradford White 265-46289-01\u003c\/strong\u003e, eliminating the need for field modifications or bracket adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Design:\u003c\/strong\u003e Includes the \u003cstrong\u003epilot tube\u003c\/strong\u003e, thermopile, and electrode in a single assembly to streamline \u003cstrong\u003ewater heater repair\u003c\/strong\u003e workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Millivolt Output:\u003c\/strong\u003e High-performance \u003cstrong\u003ethermopile\u003c\/strong\u003e provides consistent voltage to the Icon System gas control valve for reliable main burner ignition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e Built with high-temperature alloys to prevent carbon buildup and pilot clogging in high-cycle applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pilot assembly compatible with Propane (LP) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific part number is calibrated for \u003cstrong\u003eNatural Gas pilot\u003c\/strong\u003e systems. Using this on LP units will result in improper combustion due to the orifice sizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eShould I replace the entire assembly or just the thermopile?\u003c\/strong\u003e\u003cbr\u003e\nReplacing the complete \u003cstrong\u003e265-46289-01 assembly\u003c\/strong\u003e is recommended to ensure the pilot flame geometry and electrode alignment meet factory standards, preventing future service calls.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this fit all Bradford White Defender models?\u003c\/strong\u003e\u003cbr\u003e\nIt is designed for many models using the Icon System, but you must verify your specific model and serial number to ensure the mounting bracket and tube length match your heating chamber.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650768268,"sku":"415-46289-01","price":299.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_c9baa00b-e7de-40e0-b413-4cf0ea5f43b4.jpg?v=1654884070"},{"product_id":"415-46616-00","title":"Bradford White 415-46616-00 Control Board","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-46616-00 Control Board\u003c\/strong\u003e is the OEM \u003cstrong\u003eintegrated ignition control\u003c\/strong\u003e designed for precise management of gas-fired water heater operations. This specific \u003cstrong\u003ehot surface ignition (HSI)\u003c\/strong\u003e module serves as the direct \u003cstrong\u003e233-46616-00 replacement\u003c\/strong\u003e, ensuring seamless mechanical and electrical compatibility with existing wiring harnesses. Engineered for high-recovery commercial and residential atmospheric vent units, this \u003cstrong\u003ewater heater circuit board\u003c\/strong\u003e regulates the gas valve, flame sensing, and inducer blower timing to maintain optimal thermal efficiency. It is built to withstand the high-ambient conditions found in mechanical rooms, preventing premature component failure due to thermal stress. For technicians performing a \u003cstrong\u003eBradford White water heater repair\u003c\/strong\u003e, this board provides reliable flame rectification and diagnostic feedback via onboard LED indicators, streamlining the troubleshooting process. Maintaining precise \u003cstrong\u003eHVAC control board\u003c\/strong\u003e parameters is critical for preventing lockout cycles and ensuring consistent burner ignition across various gas pressures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Fit:\u003c\/strong\u003e Ensures 100% compatibility as the official \u003cstrong\u003ereplacement control board\u003c\/strong\u003e for legacy 233-46616-00 systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Flame Sensing:\u003c\/strong\u003e Superior circuitry for accurate flame rectification, reducing nuisance lockouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Onboard LED status lights provide immediate error code identification for faster service calls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Built to handle the voltage fluctuations and high temperatures common in water heating applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Plug-and-play architecture minimizes field wiring errors and reduces labor time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Technical Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 415-46616-00 compatible with older Bradford White models?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003eBradford White 415-46616-00\u003c\/strong\u003e is the manufacturer-authorized superseding part for the 233-46616-00. If your service manual specifies the older part number, this is the current technical replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a lockout on this board?\u003c\/strong\u003e\u003cbr\u003e\nRefer to the integrated LED flash codes. Most lockouts on these \u003cstrong\u003ecommercial water heater parts\u003c\/strong\u003e stem from poor grounding, dirty flame sensors, or inconsistent 120VAC supply voltage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this board control the gas valve directly?\u003c\/strong\u003e\u003cbr\u003e\nYes, it manages the 24V signal to the gas valve solenoid after confirming the hot surface igniter has reached the required temperature for safe combustion.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650944332,"sku":"415-46616-00","price":272.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_4622f0a2-f18d-4acb-b497-685ffd0c5ca2.jpg?v=1591048457"},{"product_id":"bradford-white-265-46182-01-valve-kit","title":"Bradford White 265-46182-01 Valve Kit","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-46182-01 Valve Kit\u003c\/strong\u003e is a direct OEM replacement \u003cstrong\u003eLP gas control valve\u003c\/strong\u003e engineered for precise thermal regulation in \u003cstrong\u003eBradford White Defender Safety System\u003c\/strong\u003e water heaters. This \u003cstrong\u003eSit Proflame gas valve\u003c\/strong\u003e features an integrated \u003cstrong\u003ethermostat control\u003c\/strong\u003e and a \u003cstrong\u003epiezo igniter\u003c\/strong\u003e assembly, ensuring reliable pilot ignition and consistent burner manifold pressure. Designed for \u003cstrong\u003eliquid propane\u003c\/strong\u003e applications, the 265-46182-01 manages gas flow through a robust internal diaphragm, maintaining stable operation even under varying inlet pressures. For HVACR contractors, this kit simplifies field repairs by providing a factory-calibrated solution for \u003cstrong\u003ehot water heater troubleshooting\u003c\/strong\u003e involving erratic temperature swings or pilot outages. The assembly utilizes standard CC threads for thermocouple and pilot line integration, ensuring a secure, leak-free connection. When replacing this \u003cstrong\u003eLP gas water heater part\u003c\/strong\u003e, technicians should verify the specific serial number compatibility to maintain the integrity of the flammable vapor ignition resistant (FVIR) system.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Precision:\u003c\/strong\u003e Genuine \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e ensures exact fitment and maintains the unit’s original safety ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Durability:\u003c\/strong\u003e Built with high-grade internal components to resist scale buildup and ensure long-term \u003cstrong\u003eLP gas\u003c\/strong\u003e flow accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Features integrated \u003cstrong\u003epiezo ignition\u003c\/strong\u003e components to reduce diagnostic time during field service calls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Specifically calibrated for the \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e to prevent nuisance tripping and pilot failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I diagnose a faulty Bradford White gas control valve?\u003c\/strong\u003e\u003cbr\u003e\nTechnicians should first check for millivolt output from the thermocouple. If the pilot stays lit but the main burner fails to engage despite proper thermopile voltage, the internal solenoid in the \u003cstrong\u003e265-46182-01 valve\u003c\/strong\u003e is likely defective.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this valve be used for natural gas conversions?\u003c\/strong\u003e\u003cbr\u003e\nNo, this kit is specifically orifice-regulated for \u003cstrong\u003eliquid propane (LP)\u003c\/strong\u003e. Installing this on a natural gas system will result in improper combustion and hazardous operating conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the standard manifold pressure for this LP valve?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003ewater heater gas valve\u003c\/strong\u003e is typically factory-set to maintain 10.0\" W.C. for liquid propane, though technicians should always verify specifications via the heater's rating plate during commissioning.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35650974540,"sku":"265-46182-01","price":258.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_ade13355-0f7f-4622-9d48-0c5b33de9b4a.jpg?v=1653594682"},{"product_id":"bradford-white-415-45613-01-gas-valve","title":"Bradford White 415-45613-01 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-45613-01 Gas Valve\u003c\/strong\u003e is an OEM \u003cstrong\u003e120v 4\" NAT gas valve\u003c\/strong\u003e designed for precise fuel regulation in high-efficiency commercial water heating systems. This \u003cstrong\u003ehot surface ignition gas valve\u003c\/strong\u003e is a direct drop-in \u003cstrong\u003ereplacement for 239-45613-01\u003c\/strong\u003e and \u003cstrong\u003e100327116\u003c\/strong\u003e, ensuring seamless integration with existing manifold configurations. Engineered for reliability in high-demand environments, this \u003cstrong\u003enatural gas control valve\u003c\/strong\u003e manages the combustion sequence by interfacing directly with the water heater’s electronic control board. The 4-inch spacing is critical for maintaining correct burner alignment and thermal input ratings. As an essential \u003cstrong\u003eHVAC replacement part\u003c\/strong\u003e, it ensures the unit operates within manufacturer pressure specifications, preventing low-heat cycles or ignition failures. For technicians performing \u003cstrong\u003egas valve troubleshooting\u003c\/strong\u003e, this component provides the exact electrical specifications required to maintain the system's original AHRI-certified performance levels without necessitating field modifications to the supply piping or wire harness.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Ensures a perfect fit for \u003cstrong\u003eBradford White 415-45613-01\u003c\/strong\u003e applications, eliminating the need for retrofitting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Pressure Regulation:\u003c\/strong\u003e Maintains consistent \u003cstrong\u003emanifold pressure\u003c\/strong\u003e for stable combustion and optimal thermal efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Features standard 120V electrical connections and a 4-inch profile for rapid field replacement during service calls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Ignition Control:\u003c\/strong\u003e Designed specifically for HSI systems, ensuring safe and consistent main burner light-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the correct replacement for a 239-45613-01 valve?\u003c\/strong\u003e\u003cbr\u003e\nYes, this unit is the authorized manufacturer replacement for part numbers 239-45613-01 and 100327116.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this valve be field-converted to Liquid Propane (LP)?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific model is a dedicated \u003cstrong\u003enatural gas water heater valve\u003c\/strong\u003e. Using it with LP gas without a manufacturer-approved conversion kit is unsafe and will lead to improper combustion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing 120v gas valve?\u003c\/strong\u003e\u003cbr\u003e\nCommon indicators include the hot surface igniter glowing without the main burner lighting, frequent \"no ignition\" lockout codes on the control board, or inconsistent manifold pressure readings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651231948,"sku":"415-45613-01","price":352.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_2901bbb7-b1e3-4820-ae68-4e87815c33ef.png?v=1710438414"},{"product_id":"bradford-white-239-48795-01-gas-valve","title":"Bradford White 239-48795-01 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 239-48795-01\u003c\/strong\u003e is a genuine \u003cstrong\u003eOEM natural gas valve\u003c\/strong\u003e designed for high-performance residential power vent water heaters. This control serves as the \u003cstrong\u003edirect replacement for 239-45613-02\u003c\/strong\u003e, ensuring seamless integration with existing burner assemblies without the need for field modifications. Engineered specifically for the \u003cstrong\u003eBradford White ICON System\u003c\/strong\u003e, this valve provides precise thermostatic control and integrated \u003cstrong\u003eflammable vapor sensor\u003c\/strong\u003e logic to maintain strict safety standards and operational efficiency.\u003c\/p\u003e\n\n\u003cp\u003eAs a veteran-grade \u003cstrong\u003ereplacement gas control valve\u003c\/strong\u003e, the 239-48795-01 is compatible with \u003cstrong\u003eBradford White M1TW40S and M1TW50S\u003c\/strong\u003e models, as well as select PDX series units. This \u003cstrong\u003ewater heater gas valve\u003c\/strong\u003e features a 3-5\/8 inch shank and is rated for a 160°F temperature setpoint. For contractors performing \u003cstrong\u003epower vent water heater troubleshooting\u003c\/strong\u003e, this 24V redundant valve utilizes an immersion-style thermistor to provide real-time diagnostic codes via an LED status light, simplifying the identification of ignition or sensor-related faults in the field.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Match:\u003c\/strong\u003e Provides an exact \u003cstrong\u003ereplacement for 239-45613-02\u003c\/strong\u003e, maintaining original equipment performance and safety certifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e Integrated LED status indicator allows for rapid \u003cstrong\u003ewater heater gas valve troubleshooting\u003c\/strong\u003e by displaying specific fault codes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Temperature Regulation:\u003c\/strong\u003e High-accuracy immersion thermistor ensures consistent hot water delivery and prevents thermal stacking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Safety:\u003c\/strong\u003e Contains localized logic for \u003cstrong\u003eflammable vapor sensor\u003c\/strong\u003e monitoring and high-limit ECO (Energy Cut-Off) protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 239-48795-01 compatible with LP (Propane) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific part number is calibrated exclusively for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e. Using this in an LP application will cause improper combustion. For LP requirements, please refer to the 239-48796 series.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this valve require a special tool for installation?\u003c\/strong\u003e\u003cbr\u003e\nWhile the 239-48795-01 uses standard NPT threads, certain legacy kits it replaces (like the 239-45613-02) originally required a specific service tool for the shank. This replacement is designed to meet modern \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e standards for standard mechanical installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I read the diagnostic light on the gas control?\u003c\/strong\u003e\u003cbr\u003e\nThe flashing LED on the front of the \u003cstrong\u003eICON System gas valve\u003c\/strong\u003e identifies specific errors like \"1 flash\" for sensor failure or \"constant light\" for a tripped ECO. Refer to the service manual on the inner cover for the fault code legend.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651275980,"sku":"415-48795-01","price":359.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_55200294-b5de-4e9e-9a3c-b13e2864f7bc.jpg?v=1617397211"},{"product_id":"415-45614-01","title":"Bradford White 415-45614-01 Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-45614-01 Valve\u003c\/strong\u003e is a critical \u003cstrong\u003eOEM replacement gas control valve\u003c\/strong\u003e engineered for high-performance liquid propane water heaters. Operating at \u003cstrong\u003e120V\u003c\/strong\u003e with a manifold pressure of \u003cstrong\u003e4\" WC LP\u003c\/strong\u003e and a maximum inlet pressure of \u003cstrong\u003e1\/2 PSI\u003c\/strong\u003e, this component ensures precise fuel regulation and ignition sequencing. This specific model serves as the official \u003cstrong\u003e239-45614-01 replacement valve\u003c\/strong\u003e, featuring a \u003cstrong\u003edirect spark ignition (DSI)\u003c\/strong\u003e interface and an integrated microprocessor for constant monitoring of the flame sensor and limit switches. Designed for seamless integration with Bradford White's \u003cstrong\u003ee-F3-80S and e-F3-100S series\u003c\/strong\u003e, it utilizes a \u003cstrong\u003ehoneywell gas control\u003c\/strong\u003e platform to maintain thermal efficiency and safety. For contractors handling \u003cstrong\u003ecommercial water heater repair\u003c\/strong\u003e, this valve provides the necessary reliability for high-recovery systems. Proper installation requires verifying the \u003cstrong\u003ewater heater gas valve settings\u003c\/strong\u003e and ensuring the 1\/2\" NPT connections are torqued to spec to prevent leaks in the fuel train.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Engineered as a drop-in replacement for part number \u003cstrong\u003e239-45614-01\u003c\/strong\u003e, eliminating field modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e The control module features LED status indicators to streamline troubleshooting and reduce downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Pressure Regulation:\u003c\/strong\u003e Fixed \u003cstrong\u003e4\" WC LP gas\u003c\/strong\u003e setting provides consistent BTU output for specialized liquid propane applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built to withstand the high-ambient temperatures common in mechanical rooms and commercial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat models is the Bradford White 415-45614-01 valve compatible with?\u003c\/strong\u003e\u003cbr\u003e\nThis valve is primarily used in commercial \u003cstrong\u003eBradford White LP gas water heaters\u003c\/strong\u003e, specifically within the e-F3 series. Always verify the model and serial number on the rating plate before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this valve be used for natural gas conversions?\u003c\/strong\u003e\u003cbr\u003e\nNo, this valve is factory-set for \u003cstrong\u003e4\" WC LP Gas\u003c\/strong\u003e. Using this component in a natural gas system without a certified conversion kit and regulator adjustment will lead to improper combustion and equipment failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this part replace the 239-45614-01?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e415-45614-01\u003c\/strong\u003e is the updated manufacturer-authorized replacement for the discontinued 239-45614-01 SKU.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651412556,"sku":"415-45614-01","price":310.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_56f966fe-a303-4b69-b843-bc9d57ff4d88.jpg?v=1599077690"},{"product_id":"bradford-white-233-42013-01-gas-pilot","title":"Bradford White 233-42013-01 Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 233-42013-01 Natural Gas Pilot Assembly\u003c\/strong\u003e is a direct OEM replacement component engineered for precision ignition in \u003cstrong\u003eBradford White water heaters\u003c\/strong\u003e. This assembly features a robust \u003cstrong\u003ethermopile\u003c\/strong\u003e and \u003cstrong\u003ethermocouple\u003c\/strong\u003e configuration designed to maintain a consistent millivolt signal to the gas control valve, ensuring reliable burner ignition and flame sensing. Designed specifically for \u003cstrong\u003enatural gas water heater repair\u003c\/strong\u003e, the assembly includes the pilot orifice, electrode, and high-temperature lead wires necessary for a complete \u003cstrong\u003epilot light assembly replacement\u003c\/strong\u003e. It integrates seamlessly with the \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e (FVIR) to prevent accidental combustion of flammable vapors outside the unit. For technicians, this \u003cstrong\u003egenuine Bradford White part\u003c\/strong\u003e ensures factory-spec tolerances for gas flow and mounting alignment, reducing call-backs caused by pilot outages or weak millivolt output. Replace the entire assembly when the pilot fails to stay lit or the thermopile output falls below 400mV under load to restore domestic hot water system performance.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Exact fit for \u003cstrong\u003eBradford White pilot assembly 233-42013-01\u003c\/strong\u003e, eliminating field modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Flame Sensing:\u003c\/strong\u003e High-grade \u003cstrong\u003ethermocouple\u003c\/strong\u003e materials ensure stable millivolt generation for consistent gas valve operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVACR Professional Grade:\u003c\/strong\u003e Built to withstand high-combustion chamber temperatures without premature oxidation of lead wires.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Includes pre-assembled mounting bracket for rapid integration with the existing burner manifold.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if the pilot assembly or the gas valve is faulty?\u003c\/strong\u003e\u003cbr\u003e\nTest the \u003cstrong\u003ethermopile millivolt output\u003c\/strong\u003e with a multimeter while the pilot is lit; if it reads below the required threshold (typically 400-750mV) despite a clean flame, the assembly requires replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this assembly include the pilot orifice?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003enatural gas pilot assembly\u003c\/strong\u003e comes with the calibrated orifice pre-installed to ensure the correct fuel-to-air ratio for Bradford White burners.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this part compatible with Liquid Propane (LP) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific part number is engineered strictly for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e. Using natural gas orifices in LP applications creates a significant safety hazard.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651534348,"sku":"233-42013-01","price":275.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_2938dedd-2852-48db-91b6-8b0103732f72.jpg?v=1593722074"},{"product_id":"bradford-white-222-80830-02-gas-valve","title":"Bradford White 222-80830-02 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 222-80830-02 Gas Valve\u003c\/strong\u003e is a direct replacement \u003cstrong\u003eWhite-Rodgers 37C73U-845\u003c\/strong\u003e integrated control designed for precise manifold pressure regulation in residential water heaters. This \u003cstrong\u003enatural gas water heater control\u003c\/strong\u003e functions as a combination thermostat, gas valve, and spark-to-pilot ignition system. Engineered for \u003cstrong\u003eBradford White Defender Safety System\u003c\/strong\u003e models, it monitors the \u003cstrong\u003ehigh-limit switch\u003c\/strong\u003e and thermal well resistance to prevent overheating and ensure safe combustion cycles. The unit features a standard 1\/2-inch NPT inlet and out connection, providing reliable gas flow control and diagnostic LED feedback for troubleshooting pilot outages or sensor failures. For technicians, this \u003cstrong\u003eRobertshaw gas valve alternative\u003c\/strong\u003e ensures drop-in compatibility and restores factory-spec recovery rates. Proper calibration of the internal \u003cstrong\u003epressure regulator\u003c\/strong\u003e is essential during installation to maintain the required 3.5\" W.C. for optimal burner performance.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Contractors\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003eIntegrated Spark-to-Pilot (IID) ignition control eliminates the need for a standing pilot, increasing energy efficiency.\u003c\/li\u003e\n    \u003cli\u003eBuilt-in \u003cstrong\u003ehigh-limit energy cutoff (ECO)\u003c\/strong\u003e provides critical protection against runaway temperature conditions.\u003c\/li\u003e\n    \u003cli\u003eLED status indicator streamlines diagnostics, allowing for faster identification of \u003cstrong\u003ethermopile voltage\u003c\/strong\u003e issues or sensor faults.\u003c\/li\u003e\n    \u003cli\u003eDirect OEM fitment for the \u003cstrong\u003eBradford White 222-80830-02\u003c\/strong\u003e ensures no modifications are required to the gas train.\u003c\/li\u003e\n    \u003cli\u003eDesigned with a robust internal diaphragm for consistent manifold pressure regulation under variable load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Technical Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this valve compatible with LP (Propane) conversions?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific model is calibrated strictly for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e. Using this on a propane system without a conversion kit (if applicable) is unsafe due to incorrect orifice sizing and pressure settings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat do the flashing LED codes indicate on this Bradford White gas valve?\u003c\/strong\u003e\u003cbr\u003e\nThe LED pulses provide real-time troubleshooting. Common codes include single flashes for sensor failure or rapid flashes indicating a \u003cstrong\u003eflame rectification\u003c\/strong\u003e error or weak pilot signal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this replace a standard standing pilot gas valve?\u003c\/strong\u003e\u003cbr\u003e\nThis is an integrated electronic control valve designed for specific spark-ignition systems. It cannot be used to replace traditional 750mv millivolt systems or standard standing pilot valves without significant system modification.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651689996,"sku":"415-80830-02","price":337.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_dac172de-2135-4a8d-9788-7d5aad06c011.jpg?v=1631131415"},{"product_id":"bradford-white-265-47524-00-thermostat","title":"Bradford White 265-47524-00 Thermostat","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-47524-00 Thermostat\u003c\/strong\u003e is a precision-engineered \u003cstrong\u003edual probe thermostat\u003c\/strong\u003e designed specifically for \u003cstrong\u003ecommercial gas water heaters\u003c\/strong\u003e in the EF Series and high-demand residential applications. This replacement control manages high-limit and temperature regulation via a dual-sensing configuration, ensuring accurate thermal feedback and safe operation within the tank. Utilizing a standard \u003cstrong\u003e1\/2-inch NPT connection\u003c\/strong\u003e, this \u003cstrong\u003edirect replacement thermostat\u003c\/strong\u003e ensures a secure seal and seamless integration into the factory-drilled ports of compatible units. For technicians servicing \u003cstrong\u003eBradford White water heaters\u003c\/strong\u003e, this \u003cstrong\u003ethermal control switch\u003c\/strong\u003e is essential for resolving intermittent heating cycles or safety lockout conditions caused by sensor drift or probe failure. The unit is calibrated to maintain specific setpoint tolerances required for high-recovery systems, preventing excessive stacking during peak demand periods. This component is built to withstand the rigorous cycling environments of commercial plumbing systems, providing reliable field performance and straightforward installation for HVACR professionals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Technical Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Accuracy Dual Sensing:\u003c\/strong\u003e Integrated \u003cstrong\u003edual probe sensors\u003c\/strong\u003e provide redundant safety monitoring and precise temperature management.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Engineered specifically as a \u003cstrong\u003eBradford White replacement part\u003c\/strong\u003e to ensure signal compatibility with internal control boards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandardized Threading:\u003c\/strong\u003e Features a rugged \u003cstrong\u003e1\/2\" NPT\u003c\/strong\u003e tapered thread for high-pressure reliability and leak prevention.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFast Thermal Response:\u003c\/strong\u003e The probe material is optimized for rapid heat transfer, reducing lag in burner ignition and cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow do I know if my thermostat probe has failed?\u003c\/strong\u003e If the water heater displays high-limit lockout codes or fails to respond to setpoint adjustments despite voltage at the gas valve, the \u003cstrong\u003edual probe sensor\u003c\/strong\u003e may be out of spec.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs this part compatible with non-EF series tanks?\u003c\/strong\u003e This part is designed for specific \u003cstrong\u003e65-4752400\u003c\/strong\u003e configurations; always verify the model number on the rating plate to ensure proper sensor depth and resistance range.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan I use thread sealant on the probe threads?\u003c\/strong\u003e Yes, use a high-quality pipe dope or Teflon tape rated for potable water systems to ensure a watertight \u003cstrong\u003eNPT connection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651698508,"sku":"265-47524-00","price":411.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_3c040d74-d8c5-402b-aa45-93ff93cf3d40.jpg?v=1627427075"},{"product_id":"bradford-white-265-45510-02-gas-valve","title":"Bradford White 265-45510-02 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 265-45510-02 Gas Valve\u003c\/strong\u003e is a specialized \u003cstrong\u003eLP gas control valve\u003c\/strong\u003e engineered for high-recovery commercial water heating systems. As a \u003cstrong\u003e750mv millivolt gas valve\u003c\/strong\u003e, it utilizes a self-powered thermopile circuit to manage combustion without external electrical input. This OEM component features a \u003cstrong\u003e3\/4 inch NPT connection\u003c\/strong\u003e and is factory-calibrated for liquid propane, operating within a specific manifold pressure range of \u003cstrong\u003e8 to 12 inches water column\u003c\/strong\u003e. Designed as a direct replacement for \u003cstrong\u003eBradford White DM Series\u003c\/strong\u003e models, this kit includes the necessary \u003cstrong\u003ewiring harness adaptor\u003c\/strong\u003e to ensure a secure interface with existing pilot assemblies and ECO (Energy Cut-Off) circuits. When diagnosing pilot dropout or main burner ignition failure in \u003cstrong\u003ecommercial propane water heaters\u003c\/strong\u003e, this valve provides the precise regulation required to maintain thermal efficiency and safe operating parameters in demanding high-demand environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Contractors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Guaranteed fit for Bradford White models DM38T155, DM75T125, DM75T160, DM80T180, and DM80T199.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Regulation:\u003c\/strong\u003e Maintains consistent \u003cstrong\u003eLP gas pressure\u003c\/strong\u003e between 8\" and 12\" W.C. for optimal burner performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMillivolt System Ready:\u003c\/strong\u003e Integrated \u003cstrong\u003e750mv\u003c\/strong\u003e operation allows for reliable functionality in non-powered applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Installation Kit:\u003c\/strong\u003e Includes the essential harness adaptor for quick field replacement and reduced downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e Built to withstand the high-cycle demands of commercial domestic hot water (DHW) applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Technical Insights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the manifold pressure setting for this valve?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003eLP gas valve\u003c\/strong\u003e is designed for a manifold pressure of 8\" to 12\" W.C. Always use a manometer to verify the pressure during commissioning to ensure it matches the heater’s rating plate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this valve require an external power source?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is a \u003cstrong\u003e750mv millivolt system\u003c\/strong\u003e. It generates the necessary voltage through the thermopile in the pilot flame assembly to operate the solenoid.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this valve be used for Natural Gas applications?\u003c\/strong\u003e\u003cbr\u003e\nNo, the \u003cstrong\u003eBradford White 265-45510-02\u003c\/strong\u003e is specifically calibrated for Liquefied Petroleum (Propane) and should not be used in Natural Gas systems due to different orifice and pressure requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant Safety Information:\u003c\/strong\u003e\u003cbr\u003e\nWarning: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (California Proposition 65).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651800012,"sku":"265-45510-02","price":308.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_264b52af-b0c1-418f-8769-1ca6adabca7b.jpg?v=1619211733"},{"product_id":"bradford-white-265-45510-01-gas-valve","title":"Bradford White 265-45510-01 Gas Valve","description":"\u003cp\u003eProfessional-grade \u003cstrong\u003eBradford White 265-45510-01\u003c\/strong\u003e is a \u003cstrong\u003eHoneywell natural gas valve\u003c\/strong\u003e designed for heavy-duty millivolt water heater applications. Operating at a \u003cstrong\u003e750mV power output\u003c\/strong\u003e and a factory-calibrated \u003cstrong\u003e4.5\" WC natural gas pressure\u003c\/strong\u003e, this \u003cstrong\u003eOEM replacement gas valve\u003c\/strong\u003e ensures precise manifold pressure and safe ignition cycles for compatible Bradford White units. Featuring a \u003cstrong\u003e1\/2\" NPT inlet\u003c\/strong\u003e and \u003cstrong\u003e1\/2\" NPT outlet\u003c\/strong\u003e, this valve provides a direct mechanical fit for designated \u003cstrong\u003eDM-series models\u003c\/strong\u003e. Designed for reliability in residential and commercial settings, the kit often includes a \u003cstrong\u003eharness adapter\u003c\/strong\u003e for seamless integration into the existing pilot and thermocouple circuitry. Professional installation by a licensed tech is required to ensure proper \u003cstrong\u003emillivolt gas control system\u003c\/strong\u003e performance and leak-free seating. This \u003cstrong\u003eBradford White gas valve kit\u003c\/strong\u003e is critical for restoring system efficiency when a standing pilot fails to stay lit or the main burner bypass fails to actuate under load.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Exact replacement part ensures no modification is needed for \u003cstrong\u003eBradford White 265-45510-01\u003c\/strong\u003e installations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTechnical Precision:\u003c\/strong\u003e Pre-set to \u003cstrong\u003e4.5\" WC pressure\u003c\/strong\u003e for optimal \u003cstrong\u003enatural gas water heater\u003c\/strong\u003e combustion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Setup:\u003c\/strong\u003e Includes a \u003cstrong\u003eharness adapter\u003c\/strong\u003e to resolve wiring mismatches in older service calls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMillivolt Efficiency:\u003c\/strong\u003e Designed for \u003cstrong\u003e750mV systems\u003c\/strong\u003e, providing autonomous operation without external line voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the signs of a failing Bradford White 265-45510-01?\u003c\/strong\u003e\u003cbr\u003e\nContractors usually diagnose a failed \u003cstrong\u003emillivolt natural gas valve\u003c\/strong\u003e when the pilot won't hold despite a good thermocouple reading, or when there is insufficient gas flow to the main burner.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the Bradford White 265-45510-01 a universal valve?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is a \u003cstrong\u003egenuine OEM repair part\u003c\/strong\u003e specifically calibrated for Bradford White water heaters. Verify your model and serial number to ensure the \u003cstrong\u003e1\/2\" inlet\/outlet\u003c\/strong\u003e and \u003cstrong\u003e4.5\" WC setting\u003c\/strong\u003e are correct for your application.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this gas valve include a pilot assembly?\u003c\/strong\u003e\u003cbr\u003e\nThis SKU covers the \u003cstrong\u003eHoneywell gas valve\u003c\/strong\u003e and harness adapter; the pilot assembly and thermocouple are typically sold separately unless specified in the service kit.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651800140,"sku":"265-45510-01","price":330.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_b77e1b56-b6ee-42c6-8bfa-fd7169941bbf.jpg?v=1619211261"},{"product_id":"bradford-white-233-46038-00-thermostat","title":"Bradford White 243-50002-00 Thermostat","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 243-50002-00 Thermostat\u003c\/strong\u003e serves as a critical \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e for high-efficiency water heating systems, providing accurate temperature regulation and safety monitoring. This specific \u003cstrong\u003egas water heater thermostat\u003c\/strong\u003e features an integrated \u003cstrong\u003ethermistor assembly\u003c\/strong\u003e, ensuring precise resistance readings to communicate with the control board. As the direct \u003cstrong\u003eupdated version for 233-46038-00\u003c\/strong\u003e, this component is engineered to resolve common \u003cstrong\u003epilot lighting issues\u003c\/strong\u003e and erratic temperature fluctuations found in older iterations. For HVAC technicians, this \u003cstrong\u003eBradford White 243-50002-00\u003c\/strong\u003e is an essential truck-stock item when servicing \u003cstrong\u003eDefender Safety System\u003c\/strong\u003e models. The unit utilizes a \u003cstrong\u003esurface-mount sensor\u003c\/strong\u003e to monitor tank surface temperatures, preventing overheating through a built-in \u003cstrong\u003eenergy cut-off (ECO)\u003c\/strong\u003e mechanism. Professional installation is required to ensure the \u003cstrong\u003eimmersion thermistor\u003c\/strong\u003e is seated correctly within the well, maintaining the thermal conductivity necessary for optimal \u003cstrong\u003ethermal runaway protection\u003c\/strong\u003e and consistent \u003cstrong\u003ehot water recovery rates\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect OEM Matching:\u003c\/strong\u003e Designed specifically for Bradford White inventory, eliminating fitment issues common with universal controls.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAdvanced Feedback:\u003c\/strong\u003e The \u003cstrong\u003ethermistor probe\u003c\/strong\u003e provides millivolt-sensitive data to the gas valve for tighter differential control.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced Reliability:\u003c\/strong\u003e Replaces the legacy \u003cstrong\u003e233-46038-00\u003c\/strong\u003e, utilizing improved internal circuitry to mitigate sensor drift.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIntegrated Safety:\u003c\/strong\u003e Features a high-limit thermal switch that interrupts the gas flow if temperatures exceed set parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot a 243-50002-00 thermostat error code?\u003c\/strong\u003e\u003cbr\u003e\nTechnicians should check for continuity across the thermistor and verify that resistance values match the Bradford White temperature-to-resistance chart found in the service manual.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this thermostat fit my specific Bradford White model?\u003c\/strong\u003e\u003cbr\u003e\nThis part is the designated successor to the 233-46038-00. Check the rating plate on your tank to ensure compatibility with the Defender Safety System ignition series.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is the thermistor integrated into this unit?\u003c\/strong\u003e\u003cbr\u003e\nThe integrated design ensures that the control board receives accurate real-time data from a calibrated source, preventing communication errors between the tank and the gas control valve.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35651896460,"sku":"243-50002-00","price":199.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_7c6b7baf-355b-4654-a79c-2afac213b703.png?v=1529356633"},{"product_id":"239-47463-01","title":"Bradford White 239-47463-01 Kit","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 239-47463-01 Kit\u003c\/strong\u003e is a direct OEM replacement designed specifically for the \u003cstrong\u003eIcon System gas control valve\u003c\/strong\u003e platform. This comprehensive kit includes both the \u003cstrong\u003emillivolt natural gas valve\u003c\/strong\u003e and the necessary pilot assembly components to restore proper ignition and temperature regulation in Bradford White residential water heaters. Engineered for precision, the valve utilizes an internal thermopile to generate the required millivoltage, eliminating the need for external power while maintaining tight \u003cstrong\u003ewater heater temperature control\u003c\/strong\u003e. It is essential for service technicians addressing lockout codes or pilot outages common in older atmospheric vent units. When replacing the \u003cstrong\u003e239-47463-01 control valve\u003c\/strong\u003e, ensure the manifold pressure is clocked according to the rating plate specifications to maintain optimal combustion efficiency. This kit simplifies the workflow by providing the high-limit switch and pilot interface in one package, ensuring a secure seal and reliable \u003cstrong\u003ereplacement water heater parts\u003c\/strong\u003e installation for high-demand residential environments.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Specifically engineered for \u003cstrong\u003eBradford White Icon System\u003c\/strong\u003e gas water heaters to ensure exact fit and function.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Diagnostics:\u003c\/strong\u003e Integrated LED status light provides clear troubleshooting codes for faster field diagnostics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Includes a factory-calibrated high-limit energy cut-off (ECO) to prevent overheating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Ignition:\u003c\/strong\u003e Complete pilot assembly ensures consistent flame rectification and burner ignition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built to withstand commercial-grade usage in residential applications for \u003cstrong\u003enatural gas water heater repair\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWill this valve work for propane (LP) units?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific kit is calibrated for natural gas. For propane applications, a dedicated LP conversion or LP-specific valve kit must be used to ensure safe manifold pressure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit include the pilot tubing and thermopile?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 239-47463-01 includes the pilot assembly, which consists of the pilot tube, electrode, and thermopile required for the Icon System interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I troubleshoot the LED blink codes on this valve?\u003c\/strong\u003e\u003cbr\u003e\nThe status light blinks in specific sequences to indicate issues such as thermal well overheating, sensor failure, or unstable pilot flame. Refer to the technical service manual for the blink code matrix.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35652048396,"sku":"415-52907-01","price":282.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/bradford-white-239-47463-01-kit-16_3aa530c5-aec4-49cb-b8b4-d666bde5c5dc.jpg?v=1516063687"},{"product_id":"415-53359-00","title":"Bradford White 415-53359-00 Control","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 415-53359-00 ICON Gas Control Valve\u003c\/strong\u003e is a direct replacement for the legacy \u003cstrong\u003e239-47851-00\u003c\/strong\u003e, engineered specifically for \u003cstrong\u003enatural gas water heaters\u003c\/strong\u003e. This \u003cstrong\u003emillivolt-powered thermostat\u003c\/strong\u003e utilizes an intelligent gas control system that eliminates the need for external electricity, relying on a \u003cstrong\u003ethermopile\u003c\/strong\u003e to power the \u003cstrong\u003eintegrated piezo igniter\u003c\/strong\u003e and control circuit. Designed for high-performance residential applications, this valve features a precise \u003cstrong\u003emicroprocessor control\u003c\/strong\u003e that monitors tank temperatures to ensure narrow differential operation and consistent \u003cstrong\u003ethermal output\u003c\/strong\u003e. The 415-53359-00 is critical for maintaining \u003cstrong\u003ecombustion safety\u003c\/strong\u003e and \u003cstrong\u003eEnergy Star compliance\u003c\/strong\u003e through its advanced \u003cstrong\u003eLED status indicator\u003c\/strong\u003e, which provides real-time diagnostics for service technicians. This \u003cstrong\u003enatural gas water heater control\u003c\/strong\u003e is built with a rugged \u003cstrong\u003emanifold pressure regulator\u003c\/strong\u003e and \u003cstrong\u003ehigh-limit switch\u003c\/strong\u003e to prevent overheating. When performing a \u003cstrong\u003ewater heater thermostat replacement\u003c\/strong\u003e, this genuine OEM part ensures exact \u003cstrong\u003eflange alignment\u003c\/strong\u003e and \u003cstrong\u003eNPT thread compatibility\u003c\/strong\u003e with the original tank configuration.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect OEM Compatibility:\u003c\/strong\u003e Serves as the factory-authorized replacement for the \u003cstrong\u003e239-47851-00\u003c\/strong\u003e, ensuring zero-clearance issues during \u003cstrong\u003enatural gas valve installation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Diagnostics:\u003c\/strong\u003e Features an integrated \u003cstrong\u003eLED error code system\u003c\/strong\u003e to streamline troubleshooting of \u003cstrong\u003ethermopile voltage\u003c\/strong\u003e or pilot assembly failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMillivolt Operation:\u003c\/strong\u003e Operates independently of house current, making it a reliable solution for maintaining hot water during power outages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Safety:\u003c\/strong\u003e Includes a factory-calibrated \u003cstrong\u003eECO (Energy Cut-Off)\u003c\/strong\u003e and high-limit sensor to protect against excessive water temperatures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I fix a blinking red light on my Bradford White gas control valve?\u003c\/strong\u003e\u003cbr\u003e\nThe blinking LED is an \u003cstrong\u003eICON system diagnostic tool\u003c\/strong\u003e. Refer to the technical service manual to correlate the number of flashes with specific codes, such as \u003cstrong\u003elow millivoltage\u003c\/strong\u003e or a \u003cstrong\u003etripped thermal switch\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use the 415-53359-00 to replace a liquid propane (LP) valve?\u003c\/strong\u003e\u003cbr\u003e\nNo. This control is calibrated for \u003cstrong\u003enatural gas manifold pressure\u003c\/strong\u003e and \u003cstrong\u003eorifice sizing\u003c\/strong\u003e. Installing this on an LP system creates a significant safety hazard; always match the fuel type to the \u003cstrong\u003eOEM part number\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the piezo igniter included with this gas control?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003eBradford White ICON system\u003c\/strong\u003e includes the integrated \u003cstrong\u003epiezoelectric igniter\u003c\/strong\u003e, simplifying the \u003cstrong\u003epilot lighting procedure\u003c\/strong\u003e without requiring external tools.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35653426892,"sku":"415-53359-00","price":707.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_53cb54c5-0a1d-4d30-b058-3c6b036b005c.jpg?v=1596563933"},{"product_id":"bradford-white-243-42780-01-gas-valve","title":"Bradford White 243-42780-01 Gas Valve","description":"\u003cp\u003eThe \u003cstrong\u003eBradford White 243-42780-01 Gas Valve\u003c\/strong\u003e is an OEM-grade \u003cstrong\u003eNatural Gas gas control valve\u003c\/strong\u003e designed for specific high-capacity commercial and residential water heating applications. Operating on a \u003cstrong\u003e24V AC\u003c\/strong\u003e circuit, this valve features a \u003cstrong\u003e3\/4-inch NPT inlet and outlet\u003c\/strong\u003e to handle increased flow requirements. It is factory-calibrated for a \u003cstrong\u003e4.5\" WC manifold pressure\u003c\/strong\u003e, ensuring consistent thermal output and burner efficiency across high-demand cycles. As a specialized \u003cstrong\u003e24V water heater gas valve\u003c\/strong\u003e, it integrates seamlessly with \u003cstrong\u003eintermittent pilot ignition (IPI)\u003c\/strong\u003e systems or electronic controls typically found in \u003cstrong\u003eBradford White commercial water heaters\u003c\/strong\u003e. Contractors should verify the \u003cstrong\u003e4.5-inch water column\u003c\/strong\u003e rating against the equipment's rating plate to prevent over-firing. This robust component provides reliable safety shut-off and precise fuel regulation, making it a critical replacement part for maintaining system integrity and meeting strict NOx or combustion standards in professional HVACR installations.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Flow Rate:\u003c\/strong\u003e Large \u003cstrong\u003e3\/4\" NPT connections\u003c\/strong\u003e support high-BTU load requirements without excessive pressure drop.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUniversal 24V Compatibility:\u003c\/strong\u003e Standard \u003cstrong\u003e24V AC operation\u003c\/strong\u003e allows for straightforward integration with existing electronic ignition control boards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecision Pressure Management:\u003c\/strong\u003e Pre-set \u003cstrong\u003e4.5\" WC regulation\u003c\/strong\u003e ensures stable manifold pressure for optimal combustion and heat transfer.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Reliability:\u003c\/strong\u003e Genuine Bradford White replacement ensures physical fitment and electrical compatibility within the appliance's safety string.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this valve compatible with LP gas systems?\u003c\/strong\u003e\u003cbr\u003e\nNo, this specific model is calibrated for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e at 4.5\" WC. Conversion to Liquid Propane requires a specific LP orifice kit or a different valve model designated for 10\" WC operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this on a standard 1\/2\" gas line?\u003c\/strong\u003e\u003cbr\u003e\nThis valve uses \u003cstrong\u003e3\/4\" NPT threads\u003c\/strong\u003e. If your supply line or burner manifold is 1\/2\", you will need appropriate bushings, though it is recommended to match the OEM diameter to maintain the intended gas velocity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this valve include the pilot assembly?\u003c\/strong\u003e\u003cbr\u003e\nThis is the gas control valve only. It features ports for the pilot tube and thermocouple\/pilot sensor connections, but those components must be sourced separately or reused from the existing assembly.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":35654117260,"sku":"243-42780-01","price":11800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_139587c5-c766-4c3f-838e-4a342f3ac472.jpg?v=1604007271"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/collections\/Pic_499e0391-e26b-409c-8829-104efd54fbee.png?v=1743445986","url":"https:\/\/www.gsistore.com\/collections\/bradford-white.oembed?page=11","provider":"GSIstore","version":"1.0","type":"link"}