{"title":"COPELAND","description":"","products":[{"product_id":"copeland-020-0783-00-gasket","title":"Copeland 020-0783-00 Gasket","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland 020-0783-00 Gasket\u003c\/strong\u003e is a critical sealing component engineered for \u003cstrong\u003esemi-hermetic compressor unloader valves\u003c\/strong\u003e. Designed to withstand the high-discharge temperatures and pressure fluctuations inherent in \u003cstrong\u003ecommercial refrigeration systems\u003c\/strong\u003e, this gasket ensures a leak-proof seal at the unloader body interface. Precise tolerance manufacturing prevents refrigerant bypass, maintaining optimal \u003cstrong\u003evolumetric efficiency\u003c\/strong\u003e during capacity modulation. For contractors servicing \u003cstrong\u003eCopeland Discus compressors\u003c\/strong\u003e, utilizing this specific OEM replacement is vital for preventing system pressure loss and ensuring the \u003cstrong\u003eunloader solenoid assembly\u003c\/strong\u003e functions within factory parameters. The material composition is resistant to common \u003cstrong\u003ePOE and mineral oils\u003c\/strong\u003e, preventing degradation and premature failure in the field. This gasket is essential for \u003cstrong\u003eHVAC technician maintenance\u003c\/strong\u003e routines where high-side integrity is non-negotiable. Proper installation requires clean flange surfaces and adherence to specific torque sequences to prevent deformation of the \u003cstrong\u003evalve plate gasket\u003c\/strong\u003e surfaces.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Fit:\u003c\/strong\u003e Specifically machined for \u003cstrong\u003eCopeland 020-0783-00\u003c\/strong\u003e specifications to ensure zero-clearance sealing on unloader heads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Compatibility:\u003c\/strong\u003e Stable performance with R-22, R-134a, and R-404A systems without swelling or hardening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Thermal Stability:\u003c\/strong\u003e Maintains structural integrity under extreme discharge head temperatures to prevent \u003cstrong\u003ecompressor blow-by\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Reliability:\u003c\/strong\u003e Built to the exact metallurgical and chemical standards required for \u003cstrong\u003eindustrial HVACR\u003c\/strong\u003e applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Technical Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs this gasket compatible with all Copeland Discus unloader heads?\u003c\/strong\u003e\u003cbr\u003e\nThis gasket is designed for specific 2D, 3D, and 4D unloader valve assemblies; always verify your \u003cstrong\u003ecompressor model number\u003c\/strong\u003e against the parts list to ensure the precise bolt pattern match.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eShould I use a gasket sealant during installation?\u003c\/strong\u003e\u003cbr\u003e\nNo, this seal is designed for dry installation. Using RTV or other sealants can migrate into the \u003cstrong\u003eunloader valve ports\u003c\/strong\u003e, causing mechanical failure or clogging the solenoid orifice.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is the unloader gasket failing prematurely?\u003c\/strong\u003e\u003cbr\u003e\nPremature failure is often caused by \u003cstrong\u003ehigh discharge temperatures\u003c\/strong\u003e (above 225°F) or improper torque on the unloader bolts, which leads to gasket crushing or thermal blowouts.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland","offers":[{"title":"Default Title","offer_id":35643316940,"sku":"020-0783-00","price":4.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_8e0ad16b-f198-403c-adce-c562cf05bb48.png?v=1756165195"},{"product_id":"copeland-comfort-control-white-rodgers-f61-2550-wall-plate","title":"Copeland Comfort Control (White Rodgers) F61-2550 Wall Plate","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) F61-2550 Wall Plate\u003c\/strong\u003e is a critical accessory for finishing \u003cstrong\u003e1F70 Series thermostat\u003c\/strong\u003e installations. Measuring 6.5 inches wide by 4.5 inches high, this \u003cstrong\u003eClassic White thermostat wall plate\u003c\/strong\u003e provides a clean, professional appearance by concealing holes, paint lines, or wall damage left by previous, larger controls. As a genuine \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e, it ensures a flush, secure fit specifically for the \u003cstrong\u003eWhite Rodgers 1F70 Series\u003c\/strong\u003e line of room thermostats.\u003c\/p\u003e\n\n\u003cp\u003eFor technicians in the field, the \u003cstrong\u003eF61-2550\u003c\/strong\u003e is a standard-size solution for surface mounting directly to drywall. It is important to note that this specific model \u003cstrong\u003edoes not include an adapter plate\u003c\/strong\u003e for junction box mounting. If your application requires attachment to a vertical or horizontal junction box, verify if separate hardware is needed. Constructed from durable, high-impact plastic, this plate maintains the integrity and aesthetic of the HVAC control system in both residential and light commercial settings.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise 1F70 Compatibility:\u003c\/strong\u003e Engineered as an \u003cstrong\u003eOEM thermostat accessory\u003c\/strong\u003e designed exclusively for the \u003cstrong\u003eWhite Rodgers 1F70 Series\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional Surface Finishing:\u003c\/strong\u003e Ideal for covering wall imperfections and \"thermostat ghosting\" during upgrades.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable OEM Construction:\u003c\/strong\u003e Fabricated from rugged materials to withstand high-traffic residential or commercial environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Dimensions:\u003c\/strong\u003e Provides a 6-1\/2\" W x 4-1\/2\" H coverage area for a clean, centered interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the F61-2550 compatible with Sensi smart thermostats?\u003c\/strong\u003e\u003cbr\u003e\nNo, this wall plate is specifically sized for the \u003cstrong\u003eWhite Rodgers 1F70 Series\u003c\/strong\u003e. For Sensi models, a different \u003cstrong\u003ehorizontal thermostat wall plate\u003c\/strong\u003e like the F61-2689 is typically required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this kit include mounting screws for a junction box?\u003c\/strong\u003e\u003cbr\u003e\nThis model is designed for surface mounting and does not include the \u003cstrong\u003ejunction box adapter plate\u003c\/strong\u003e. It is intended for direct wall attachment where a standard electrical box is not used.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this for vertical 1D70 or 1E70 units?\u003c\/strong\u003e\u003cbr\u003e\nThe F61-2550 is a \u003cstrong\u003ehorizontal thermostat wallplate\u003c\/strong\u003e. While it may provide coverage, vertical series units often require specific plates like the F61-2593 to ensure correct alignment and aesthetics.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643331212,"sku":"F61-2550","price":3.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_4aeda409-36af-494a-8877-318258740031.jpg?v=1626988031"},{"product_id":"cooper-bussmann-ecnr20-fuse","title":"Cooper Bussmann ECNR20 Fuse","description":"\u003cp\u003eThe \u003cstrong\u003eBussmann ECNR20\u003c\/strong\u003e is a high-performance \u003cstrong\u003eClass RK5 fuse\u003c\/strong\u003e engineered for industrial and commercial motor protection where space and heat management are critical. This \u003cstrong\u003e20 amp dual element fuse\u003c\/strong\u003e features a 2-inch length and 9\/16-inch diameter, making it a standard fit for 250V applications requiring \u003cstrong\u003etime-delay\u003c\/strong\u003e-rated circuit protection. Unlike standard fast-acting components, the ECNR20 utilizes a specialized dual-element design that allows for temporary \u003cstrong\u003emotor starting surges\u003c\/strong\u003e without nuisance tripping, while still providing rapid response to short-circuit events up to a 200,000 RMS symmetrical amperage interrupting rating.\u003c\/p\u003e\n\n\u003cp\u003eFor technicians in the field, the ECNR20 is a preferred \u003cstrong\u003ecurrent-limiting fuse\u003c\/strong\u003e because it operates significantly cooler than comparable Class K5 or older cartridge fuses. This thermal efficiency prevents localized heat damage to fuse blocks and reduces the risk of \"needless blows\" in high-ambient HVACR environments. As a \u003cstrong\u003erejection type fuse\u003c\/strong\u003e, its physical dimensions ensure it cannot be replaced by lower-rated or non-current-limiting fuses, maintaining the safety integrity of the branch circuit. It is highly recommended for inductive loads including motors, transformers, and solenoid-operated equipment commonly found in refrigeration and air conditioning systems.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Motor Protection:\u003c\/strong\u003e True dual-element construction allows for sizing closer to full-load amps (FLA) to prevent motor burnout while overriding initial startup inrush currents.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior Thermal Management:\u003c\/strong\u003e Engineered to run cooler than standard fuses, extending the life of clips and holders while preventing thermal-related failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Interrupting Capacity:\u003c\/strong\u003e Provides reliable circuit protection in systems with available fault currents up to 200kA RMS Symmetrical.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard RK5 Compatibility:\u003c\/strong\u003e Direct replacement for any 250V Class RK5 application, ensuring wide compatibility with existing fuse blocks and disconnects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I use an ECNR20 in a non-rejection fuse holder?\u003c\/strong\u003e No, this is a rejection-type fuse designed specifically for Class R fuse clips to ensure current-limiting safety standards are maintained.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the typical time-delay for this fuse?\u003c\/strong\u003e The ECNR20 provides a minimum 10-second opening delay at 500% of its rated current (8 seconds at 500% specifically for 250V ratings 30A and below).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs this fuse suitable for DC circuits?\u003c\/strong\u003e Yes, it is rated for up to 125 Vdc, making it versatile for both AC and DC power distribution systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Cooper Bussmann","offers":[{"title":"Default Title","offer_id":35643411980,"sku":"ECNR20","price":5.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_51123b89-03df-49b0-9777-e3d1ad94e798.png?v=1694734804"},{"product_id":"copeland-comfort-control-white-rodgers-h06e-18-thermocouple","title":"Copeland Comfort Control (White Rodgers) H06E-18 Thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers H06E-18 Thermocouple\u003c\/strong\u003e is a professional-grade 18-inch \u003cstrong\u003egas pilot safety\u003c\/strong\u003e component engineered for high-reliability heat sensing in residential and commercial \u003cstrong\u003eHVAC systems\u003c\/strong\u003e. Designed as a \u003cstrong\u003euniversal thermocouple replacement\u003c\/strong\u003e, the H06E-18 features a heavy-duty \u003cstrong\u003estainless steel element\u003c\/strong\u003e that withstands high-temperature oxidation and provides consistent millivolt output to the gas valve. This model is a standard field-service solution for \u003cstrong\u003epilot burner troubleshooting\u003c\/strong\u003e, offering a 18\" lead length that fits most atmospheric burner configurations. The \u003cstrong\u003eCopeland Comfort Control\u003c\/strong\u003e H06E-18 kit includes \u003cstrong\u003euniversal adapter fittings\u003c\/strong\u003e (including push-in, nut, and clip-style), ensuring mechanical compatibility with a broad spectrum of \u003cstrong\u003egas-powered heating appliances\u003c\/strong\u003e and pilot assemblies. For technicians, the inclusion of clear instructions and individual protective packaging makes this an essential stock item for cold-weather service calls.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Includes multiple adapter clips and nuts to replace most OEM \u003cstrong\u003efurnace thermocouples\u003c\/strong\u003e and water heater sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Durability:\u003c\/strong\u003e The \u003cstrong\u003estainless steel element\u003c\/strong\u003e construction minimizes tip burnout and maintains signal integrity under constant thermal stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Output:\u003c\/strong\u003e Optimized for 18-30 millivolt operation, ensuring reliable drop-out times for safety shut-off valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Installation:\u003c\/strong\u003e Flexible 18-inch copper lead allows for easy routing through combustion chambers without kinking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Technician Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical millivolt output for the H06E-18?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003e18-inch thermocouple\u003c\/strong\u003e is designed to produce a standard 20 to 30 millivolt signal under an open circuit test, ensuring it can properly energize the power head within the gas control valve.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this kit work with LP (Propane) and Natural Gas?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003eH06E-18\u003c\/strong\u003e is a \u003cstrong\u003egas heating replacement part\u003c\/strong\u003e compatible with both Natural Gas and Liquid Propane pilot assemblies, provided the pilot flame is properly adjusted for impingement on the upper 1\/2 to 3\/8 inch of the tip.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use an 18-inch thermocouple if the original was 12 inches?\u003c\/strong\u003e\u003cbr\u003e\nYes, as long as the excess lead is safely coiled and does not interfere with the burner flame or moving parts, the \u003cstrong\u003eH06E-18\u003c\/strong\u003e serves as a functional replacement for shorter leads.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643474380,"sku":"H06E-18","price":7.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_8deece8f-bb65-4b46-a1d4-4647d1c264a8.png?v=1756165194"},{"product_id":"copeland-comfort-control-white-rodgers-h06e-24-thermocouple","title":"Copeland Comfort Control (White Rodgers) H06E-24 Thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White-Rodgers) H06E-24 Thermocouple\u003c\/strong\u003e is a high-performance \u003cstrong\u003e24-inch universal replacement thermocouple\u003c\/strong\u003e specifically engineered for standing pilot applications in \u003cstrong\u003eresidential and light commercial gas furnaces\u003c\/strong\u003e. Built with a \u003cstrong\u003edurable stainless steel element\u003c\/strong\u003e, this component provides critical flame sensing and remains stable in high-heat environments with a \u003cstrong\u003emaximum hot junction temperature of 1450°F\u003c\/strong\u003e. This model is a go-to for field technicians needing a \u003cstrong\u003e30mV thermocouple replacement\u003c\/strong\u003e that ensures consistent millivolt output to the gas valve, maintaining a safe and reliable pilot flame signal.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for maximum compatibility, the H06E-24 features a \u003cstrong\u003estandard 11\/32\" double lead thread\u003c\/strong\u003e and includes \u003cstrong\u003euniversal adapter fittings\u003c\/strong\u003e to facilitate integration into various pilot burner assemblies. It serves as a direct professional-grade replacement for common industry models, including the \u003cstrong\u003eHoneywell Q34A\u003c\/strong\u003e, \u003cstrong\u003eJohnson K19\u003c\/strong\u003e, and \u003cstrong\u003eRobertshaw 1980\u003c\/strong\u003e. Whether you are servicing a water heater or a central heating system, the \u003cstrong\u003estainless steel construction\u003c\/strong\u003e minimizes oxidation and scaling, extending the life of the pilot assembly compared to standard copper alternatives.\u003c\/p\u003e\n\n\u003ch3\u003eKey Technician Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Includes specialized \u003cstrong\u003eadapter fittings\u003c\/strong\u003e to fit most furnace and water heater pilot burners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Durability:\u003c\/strong\u003e \u003cstrong\u003eStainless steel element construction\u003c\/strong\u003e ensures resilience against \u003cstrong\u003e1450°F hot junction\u003c\/strong\u003e temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Fit:\u003c\/strong\u003e Utilizes a \u003cstrong\u003estandard 11\/32\" male nut\u003c\/strong\u003e (double lead thread) for rapid connection to 30mV gas valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Output:\u003c\/strong\u003e Provides a steady \u003cstrong\u003enominal 22-30 mV range\u003c\/strong\u003e to keep gas valves energized during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Replacement Range:\u003c\/strong\u003e Successfully replaces \u003cstrong\u003eHoneywell, Johnson Controls, and Robertshaw\u003c\/strong\u003e universal thermocouples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Installation Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical millivolt output for this model?\u003c\/strong\u003e\u003cbr\u003e\nUnder normal operating conditions with a crisp pilot flame, the \u003cstrong\u003eH06E-24\u003c\/strong\u003e should produce between \u003cstrong\u003e22mV and 30mV\u003c\/strong\u003e. If the reading drops below 15mV under load, the gas valve may drop out, indicating a need for replacement or pilot adjustment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this work with both Natural Gas and LP systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, this \u003cstrong\u003euniversal furnace thermocouple\u003c\/strong\u003e is suitable for both \u003cstrong\u003enatural gas and liquid propane (LP) burner\u003c\/strong\u003e applications, provided the pilot flame correctly envelops the top 3\/8\" to 1\/2\" of the tip.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this unit replace 750mV powerpiles?\u003c\/strong\u003e\u003cbr\u003e\nNo. The \u003cstrong\u003eH06E-24\u003c\/strong\u003e is a standard \u003cstrong\u003e30 millivolt thermocouple\u003c\/strong\u003e. If your system requires a thermopile\/generator (typically used in millivolt-only wall heaters or gas logs), you will need the G01A series rather than this model.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643477836,"sku":"H06E-24","price":7.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_6ebc0195-93ac-4f5c-8217-f83d77ebb5d8.png?v=1766378359"},{"product_id":"copeland-comfort-control-white-rodgers-3f11-180-fan-switch","title":"Copeland Comfort Control (White Rodgers) 3F11-180 Fan Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3F11-180 Fan Switch\u003c\/strong\u003e is a professional-grade \u003cstrong\u003esnap disc fan control\u003c\/strong\u003e engineered for precision thermal regulation in forced-air systems. This \u003cstrong\u003e1\/2\" bimetal disc\u003c\/strong\u003e sensor features a fixed \u003cstrong\u003e172°F cut-in temperature\u003c\/strong\u003e and a \u003cstrong\u003e30°F differential\u003c\/strong\u003e, ensuring the fan engages at 172°F and disengages once the temperature drops to 142°F. Operating with an \u003cstrong\u003eSPST switch action\u003c\/strong\u003e that closes on rise, this \u003cstrong\u003eauto reset\u003c\/strong\u003e control provides consistent circuit termination without manual intervention. Designed for seamless integration, it serves as a direct drop-in for \u003cstrong\u003eTherm-O-Disc 36T22-10856\u003c\/strong\u003e and similar \u003cstrong\u003eHVAC limit switches\u003c\/strong\u003e. With its \u003cstrong\u003e1\/4\" quick-connect terminals\u003c\/strong\u003e and standard mounting profile, this \u003cstrong\u003ebimetal thermostat\u003c\/strong\u003e is ideal for maintaining optimal airflow and preventing heat exchanger overheating in residential and commercial heating units.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Compatible with Therm-O-Disc 36T22-10856, simplifying field repairs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFixed Temperature Precision:\u003c\/strong\u003e Factory-set 172°F cut-in ensures the blower activates only when the plenum reaches the safe operating threshold.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e The 1\/2\" bimetal disc design provides fast thermal response and long-term cycling reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Wiring:\u003c\/strong\u003e Features standard 1\/4\" quick-connect terminals for rapid installation in the field.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset:\u003c\/strong\u003e Eliminates service calls for manual resetting after standard thermal cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3F11-180 compatible with furnace blower motors?\u003c\/strong\u003e\u003cbr\u003e\nYes, this switch is specifically designed to cycle furnace fans or blowers based on the air temperature rise within the heat exchanger or plenum.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does 'Close on Rise' mean for this switch?\u003c\/strong\u003e\u003cbr\u003e\nThis signifies that the electrical contacts close (completing the circuit to start the fan) when the sensed temperature rises to the set 172°F point.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this as a high-limit safety control?\u003c\/strong\u003e\u003cbr\u003e\nWhile typically used for fan control, it is essential to match the specific temperature ratings and switch actions (Open vs. Close on rise) required by the OEM manufacturer for safety limit applications.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643541580,"sku":"3F11-180","price":6.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_cbd0d934-4f46-4c0a-9424-958b13bc22b0.png?v=1756165193"},{"product_id":"copeland-comfort-control-white-rodgers-3l11-110-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L11-110 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L11-110\u003c\/strong\u003e is a high-performance \u003cstrong\u003e1\/2\" bimetal disc limit switch\u003c\/strong\u003e engineered for precise thermal regulation in industrial and residential HVACR systems. Built on the reliable \u003cstrong\u003e36T21-10845\u003c\/strong\u003e platform, this snap-action thermostat features a fixed set point, calibrated to \u003cstrong\u003eopen on rise\u003c\/strong\u003e between 105°F and 115°F. With a 30°F differential, the \u003cstrong\u003eSPST switch action\u003c\/strong\u003e ensures a consistent \u003cstrong\u003eauto reset\u003c\/strong\u003e response once the ambient temperature drops, maintaining system uptime without manual intervention. The aluminum disc cup and stainless steel mounting brackets provide superior thermal transfer and physical durability in demanding environments.\u003c\/p\u003e\n\n\u003cp\u003eFor contractors, the \u003cstrong\u003eWhite Rodgers 3L11-110\u003c\/strong\u003e offers a versatile footprint with 1\/4\" quick connect terminals and a loose ring flange, facilitating seamless integration as a \u003cstrong\u003ehigh limit safety\u003c\/strong\u003e or regulating control. Rated for 15A at 120VAC and 10A at 240VAC, this \u003cstrong\u003esnap disc thermostat\u003c\/strong\u003e handles inductive and resistive loads with high-speed contact separation to minimize arcing. Whether you are servicing a furnace, unit heater, or commercial appliance, this genuine \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e ensures accurate \u003cstrong\u003etemperature control\u003c\/strong\u003e and long-term reliability in the field.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecision Thermal Trip:\u003c\/strong\u003e Fixed 105-115°F range effectively prevents overheating in sensitive heat exchangers and air streams.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAutomated System Recovery:\u003c\/strong\u003e Integrated \u003cstrong\u003eauto reset\u003c\/strong\u003e functionality eliminates service calls for manual resets after standard thermal cycling.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Construction:\u003c\/strong\u003e Features \u003cstrong\u003estainless steel mounting brackets\u003c\/strong\u003e and an aluminum cup for corrosion resistance and rapid thermal sensitivity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e The 1\/2\" disc design is a standard form factor for a wide array of HVACR equipment and commercial appliances.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Electrical Capacity:\u003c\/strong\u003e Robust 15A rating makes it suitable for direct-line voltage applications without the need for auxiliary relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the difference between open on rise and close on rise?\u003c\/strong\u003e This 3L11-110 is \"open on rise,\" meaning it breaks the electrical circuit when the temperature hits the 105-115°F limit, serving as a safety cutoff.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan I use this to replace a manual reset limit?\u003c\/strong\u003e No. This is an automatic reset switch. For safety reasons, never replace a manual reset limit with an auto-reset model unless specified by the equipment manufacturer.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow do I mount this switch?\u003c\/strong\u003e The loose ring flange allows you to rotate the switch to line up with existing hole patterns for easier terminal positioning in tight furnace cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643541772,"sku":"3L11-110","price":7.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_a63baa67-041d-4a59-b133-640d491a6793.png?v=1756165192"},{"product_id":"copeland-comfort-control-white-rodgers-3l11-160-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L11-160 Limit Switch","description":"\u003cp\u003eAs a veteran technician, you know that a reliable \u003cstrong\u003efixed-temperature safety control\u003c\/strong\u003e is non-negotiable for system integrity. The \u003cstrong\u003eCopeland Comfort Control (White-Rodgers) 3L11-160 Limit Switch\u003c\/strong\u003e is a 1\/2-inch bimetal disc control designed specifically for high-limit applications in HVAC and heating equipment. This \u003cstrong\u003eSPST open on rise switch\u003c\/strong\u003e provides fast, positive contact separation via its snap-action design, ensuring long-term contact life and preventing nuisance trips. With a temperature setpoint range of \u003cstrong\u003e155°F to 165°F\u003c\/strong\u003e and a 30°F differential, this \u003cstrong\u003eautomatic reset limit switch\u003c\/strong\u003e restores circuit continuity once temperatures return to safe operating levels. It is a direct \u003cstrong\u003eOEM replacement limit switch\u003c\/strong\u003e for several residential and commercial heating units, cross-referencing to the \u003cstrong\u003e36T21-10851\u003c\/strong\u003e. Rated for up to 15 Amps at 240 VAC, it offers the robust electrical capacity required for demanding field environments, keeping your equipment protected from overheating while maintaining tight operational tolerances.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Contractors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFast-Response Protection:\u003c\/strong\u003e The \u003cstrong\u003ebimetal disc limit switch\u003c\/strong\u003e utilizes snap-action technology for immediate circuit interruption when the 160°F threshold is reached.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Functions as a high-authority \u003cstrong\u003eHVAC safety limit switch\u003c\/strong\u003e for a wide range of furnaces and heat pumps.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReduced Maintenance:\u003c\/strong\u003e The \u003cstrong\u003eautomatic reset\u003c\/strong\u003e feature eliminates the need for manual intervention after a temporary temperature excursion.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Engineered by \u003cstrong\u003eWhite-Rodgers\u003c\/strong\u003e for high-speed contact separation, maximizing the service life of the internal silver contacts.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEasy Retrofitting:\u003c\/strong\u003e Compact 1\/2\" disc footprint allows for seamless installation in existing mounting brackets and tight enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Technical Support:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if the 3L11-160 is the correct replacement?\u003c\/strong\u003e\u003cbr\u003e\nCheck your original part for the temperature stamp and switch action. This model triggers between 155°F and 165°F and is an \u003cstrong\u003eopen on rise\u003c\/strong\u003e switch, meaning it cuts power when it gets hot. Comparing it to cross-reference \u003cstrong\u003e36T21-10851\u003c\/strong\u003e will also confirm compatibility.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this switch require a manual reset button?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is an \u003cstrong\u003eauto-reset limit switch\u003c\/strong\u003e. Once the heat exchanger or plenum cools down by approximately 30°F from the trip point, the contacts will automatically close to resume heating operations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum electrical load for this control?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003e3L11-160\u003c\/strong\u003e is rated for \u003cstrong\u003e15 Amps\u003c\/strong\u003e at 120 VAC and up to 10 Amps at 240 VAC, making it suitable for both pilot duty and some direct-load applications.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643542348,"sku":"3L11-160","price":7.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_11f91ca4-799d-4aa2-a7f3-cf4d2733d431.png?v=1756165192"},{"product_id":"copeland-comfort-control-white-rodgers-3l11-325-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L11-325 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L11-325\u003c\/strong\u003e is a professional-grade \u003cstrong\u003e1\/2\" bimetal disc limit switch\u003c\/strong\u003e designed for high-temperature safety and regulation in HVACR systems. Engineered with a fixed \u003cstrong\u003e315 to 335 degrees F\u003c\/strong\u003e trip point, this \u003cstrong\u003e36T21-10864\u003c\/strong\u003e style control utilizes an aluminum disc cup for rapid thermal response and high-speed contact separation. As an \u003cstrong\u003eauto reset limit switch\u003c\/strong\u003e, it features \u003cstrong\u003eSPST open on rise\u003c\/strong\u003e logic, ensuring the circuit breaks immediately when reaching the upper temperature threshold and restores once the system cools by the 50-degree differential.\u003c\/p\u003e\n\u003cp\u003eConstructed for durability in demanding contractor environments, this \u003cstrong\u003ehigh temperature limit control\u003c\/strong\u003e includes a loose ring stainless steel mounting bracket for versatile surface installation. The \u003cstrong\u003e1\/4\" quick connect terminals\u003c\/strong\u003e facilitate fast field wiring, making it a reliable \u003cstrong\u003eCopeland Comfort Control (White Rodgers)\u003c\/strong\u003e\u003cstrong\u003e replacement part\u003c\/strong\u003e for furnaces, boilers, and industrial heating equipment. Rated for 15A at 120VAC and 10A at 240VAC, this snap-action thermostat provides precise thermal protection without the common failures associated with inferior components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits for HVACR Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Temperature Precision:\u003c\/strong\u003e Factory-set 315-335°F range eliminates the need for field adjustments and ensures consistent safety cut-out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSnap-Action Reliability:\u003c\/strong\u003e The \u003cstrong\u003e36T21 thermal switch\u003c\/strong\u003e mechanism minimizes internal arcing, extending the service life of electrical contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Mounting:\u003c\/strong\u003e Stainless steel brackets with loose ring design allow for easy alignment on uneven surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Handling:\u003c\/strong\u003e Rated for 3.0 FLA and 12.0 LRA at 120VAC, making it suitable for motor-driven blower applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Technical Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3L11-325 compatible with 240V systems?\u003c\/strong\u003e\u003cbr\u003eYes, this switch is rated for 120\/240 VAC applications, supporting up to 10A resistive loads at 240V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between open on rise and close on rise?\u003c\/strong\u003e\u003cbr\u003eThis limit switch is \u003cstrong\u003eopen on rise\u003c\/strong\u003e, meaning it breaks the electrical circuit when the temperature exceeds 335°F to prevent overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this switch require manual intervention after a trip?\u003c\/strong\u003e\u003cbr\u003eNo, the \u003cstrong\u003eCopeland Comfort Control (White Rodgers)\u003c\/strong\u003e\u003cstrong\u003e 3L11-325\u003c\/strong\u003e features an automatic reset, re-closing the circuit once the temperature drops below the differential setpoint.\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643543948,"sku":"3L11-325","price":8.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_8c0cdbc8-a547-40a3-8437-3d1e0d4dac0f.png?v=1776967098"},{"product_id":"copeland-comfort-control-white-rodgers-3f01-120-fan-switch","title":"Copeland Comfort Control (White Rodgers) 3F01-120 Fan Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3F01-120 Fan Switch\u003c\/strong\u003e is a high-reliability \u003cstrong\u003e3\/4 inch snap disc fan control\u003c\/strong\u003e designed for precise blower regulation in HVAC systems and appliances. Featuring a \u003cstrong\u003efixed 120-degree F cut-in\u003c\/strong\u003e and a \u003cstrong\u003e110-degree F cut-out\u003c\/strong\u003e, this \u003cstrong\u003eclose on rise switch\u003c\/strong\u003e ensures the fan engages strictly when the plenum reaches the set temperature and disengages once cooled. The \u003cstrong\u003e60T12-610046 snap disc\u003c\/strong\u003e construction offers an automatic reset, making it a critical component for maintaining secondary heat exchanger airflow or general air circulation. Built with an aluminum disc cup and a \u003cstrong\u003estainless steel mounting bracket\u003c\/strong\u003e, it fits standard flanged footprints for seamless interchangeability. For contractors, the \u003cstrong\u003e1\/4 inch quick-connect terminals\u003c\/strong\u003e and included tab-to-screw adapters allow for versatile field wiring. This SPST switch is rated for 10A at 120VAC and 5A at 240VAC, providing a durable solution for heavy-duty motor loads. If an adapter plate is necessary for your specific assembly, the F6-1798 must be sourced separately.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Standard 3\/4\" snap disc mounting holes ensure this unit replaces a wide range of OEM and universal \u003cstrong\u003efurnace fan limit switches\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Thermal Response:\u003c\/strong\u003e Fixed calibration at 120°F (Cut-in) and 110°F (Cut-out) provides consistent system cycling without the need for manual adjustment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContractor-Grade Hardware:\u003c\/strong\u003e Comes equipped with tab-to-screw terminal adapters to accommodate both legacy and modern wiring configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Features an aluminum sensing cup for rapid thermal transfer and a stainless steel flange for long-term structural integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the switch action for the 3F01-120?\u003c\/strong\u003e This is a \u003cstrong\u003eclose on rise\u003c\/strong\u003e fan switch, meaning the circuit completes and starts the fan when the temperature reaches 120°F.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes this part include the mounting plate?\u003c\/strong\u003e The switch features an integral oval flange; however, if your application requires a specific large-format adapter plate, use model F6-1798.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan this be used for limit safety?\u003c\/strong\u003e No, current 3F01 models are designated as \u003cstrong\u003efan controls\u003c\/strong\u003e. For high-temperature safety shut-off, a \"close on fall\" or \"open on rise\" limit switch must be used.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643580748,"sku":"3F01-120","price":8.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_a8c5ac98-5200-42db-a01f-c51ccbcc7129.jpg?v=1756165191"},{"product_id":"copeland-comfort-control-white-rodgers-3l01-130-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L01-130 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White-Rodgers) 3L01-130 Limit Switch\u003c\/strong\u003e is a high-reliability \u003cstrong\u003esnap disc thermostat\u003c\/strong\u003e engineered for precise thermal regulation in \u003cstrong\u003egas furnaces\u003c\/strong\u003e, air handlers, and \u003cstrong\u003eHVAC heating systems\u003c\/strong\u003e. Featuring an \u003cstrong\u003eOpen on Rise\u003c\/strong\u003e switching action, this \u003cstrong\u003e3L01 Series limit control\u003c\/strong\u003e provides essential safety by breaking the electrical circuit when temperatures reach the \u003cstrong\u003e130°F fixed cut-out\u003c\/strong\u003e point. The internal \u003cstrong\u003esnap disc\u003c\/strong\u003e mechanism ensures a crisp, positive switch action, while the \u003cstrong\u003eauto reset\u003c\/strong\u003e function restores operation once the temperature cools to the \u003cstrong\u003e115°F fixed cut-in\u003c\/strong\u003e temperature. Designed for the field technician, this 3\/4\" disc-style switch serves as a direct \u003cstrong\u003eHH19ZA130 cross reference\u003c\/strong\u003e, though professionals must verify specific cut-in requirements during installation. The inclusion of \u003cstrong\u003etab-to-screw terminal adapters\u003c\/strong\u003e and a universal mounting configuration facilitates \u003cstrong\u003equick on-job replacement\u003c\/strong\u003e, reducing system downtime and streamlining service calls for residential and commercial \u003cstrong\u003eheating equipment\u003c\/strong\u003e maintenance.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Protection:\u003c\/strong\u003e Fixed 130°F opening and 115°F closing temperatures prevent equipment overheating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Mounting:\u003c\/strong\u003e Standard 3\/4\" disc design ensures compatibility with a broad range of \u003cstrong\u003eOEM HVAC parts\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Wiring:\u003c\/strong\u003e Comes equipped with \u003cstrong\u003eterminal adapters\u003c\/strong\u003e to accommodate both spade and screw-on connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset:\u003c\/strong\u003e Self-resetting bipetal disc eliminates the need for manual intervention after a high-limit trip.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built by \u003cstrong\u003eWhite-Rodgers\u003c\/strong\u003e to withstand the high-cycle demands of modern \u003cstrong\u003efurnace limit switch\u003c\/strong\u003e applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3L01-130 a suitable replacement for the HH19ZA130?\u003c\/strong\u003e\u003cbr\u003e\nYes, it is a common cross-reference; however, always verify that the 115°F cut-in (close) temperature aligns with your specific equipment's safety sequencing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum electrical load for this limit switch?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003e3L01 series control\u003c\/strong\u003e is typically rated for pilot duty or specific inductive\/resistive loads found in 24V and 120V heating circuits; refer to the 60T11-610002 mounting flange for specific pilot duty ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this switch in a cooling application?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is an \u003cstrong\u003eOpen on Rise\u003c\/strong\u003e switch designed to break the circuit when it gets too hot, making it strictly a heating safety or limit control.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643581836,"sku":"3L01-130","price":9.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_50eb1694-c442-47c6-b4a4-034d05df0dc2.png?v=1773614919"},{"product_id":"copeland-comfort-control-white-rodgers-3l01-165-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L01-165 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L01-165 Limit Switch\u003c\/strong\u003e is a professional-grade \u003cstrong\u003esnap disc auto-reset limit switch\u003c\/strong\u003e engineered for high-limit safety and fan control in HVAC systems and industrial appliances. This \u003cstrong\u003e3\/4-inch diameter\u003c\/strong\u003e thermostatic control utilizes a \u003cstrong\u003e60T11-610069\u003c\/strong\u003e design to provide reliable thermal protection. With a \u003cstrong\u003efixed cut-out temperature of 165°F\u003c\/strong\u003e and a \u003cstrong\u003efixed cut-in of 125°F\u003c\/strong\u003e, this \u003cstrong\u003eopen-on-rise limit switch\u003c\/strong\u003e effectively interrupts the electrical circuit upon reaching the high-temperature threshold, automatically resetting once the system cools. Designed for versatility, the \u003cstrong\u003e3L01-165\u003c\/strong\u003e features \u003cstrong\u003e1\/4-inch quick-connect terminals\u003c\/strong\u003e and is rated for \u003cstrong\u003e120\/240\/277 VAC\u003c\/strong\u003e applications. Whether you are servicing a furnace, heat pump, or commercial blower, this OEM-spec \u003cstrong\u003ehigh-limit thermostat\u003c\/strong\u003e ensures exact calibration and system longevity under demanding conditions. Its \u003cstrong\u003eSPST switch action\u003c\/strong\u003e and compact \u003cstrong\u003esnap-action disc\u003c\/strong\u003e mechanism make it a standard replacement for many standard temperature-regulated safety circuits.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Temperature Regulation:\u003c\/strong\u003e Features a \u003cstrong\u003e165°F cut-out\u003c\/strong\u003e to prevent equipment overheating and a \u003cstrong\u003e125°F cut-in\u003c\/strong\u003e for automatic system recovery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Replaces \u003cstrong\u003eWhite Rodgers 3L01-165\u003c\/strong\u003e and \u003cstrong\u003e60T11-610069\u003c\/strong\u003e models, meeting strict safety standards for HVAC and appliance duty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Electrical Capacity:\u003c\/strong\u003e Rated for up to \u003cstrong\u003e25 Amps resistive\u003c\/strong\u003e and \u003cstrong\u003e125VA pilot duty\u003c\/strong\u003e, suitable for both 120V and 240V\/277V systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built with a 3\/4\" snap disc and 1\/4\" quick-connect terminals for a secure, vibration-resistant installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Safety Cycling:\u003c\/strong\u003e The \u003cstrong\u003eopen-on-rise\u003c\/strong\u003e logic serves as a critical safety switch to protect heating elements and motors from excessive thermal load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"Open on Rise\" mean for this switch?\u003c\/strong\u003e\u003cbr\u003e\nIn HVAC applications, \u003cstrong\u003eopen on rise\u003c\/strong\u003e indicates that the internal contacts will separate (breaking the circuit) when the temperature climbs to 165°F, stopping the heating source for safety. The contacts close again (completing the circuit) when the temperature drops to 125°F.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 3L01-165 compatible with my furnace blower?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003e3L01-165 limit switch\u003c\/strong\u003e is commonly used as a \u003cstrong\u003efan control\u003c\/strong\u003e or \u003cstrong\u003ehigh-limit safety\u003c\/strong\u003e in many gas and electric furnaces. Always verify the temperature ratings on your existing switch prior to replacement to ensure the 165°F\/125°F range matches your equipment specifications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this be used in 277V commercial systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e3L01-165\u003c\/strong\u003e is rated for \u003cstrong\u003e120\/240\/277 VAC\u003c\/strong\u003e, making it suitable for a wide variety of residential and commercial HVAC units.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643582412,"sku":"3L01-165","price":8.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_1f716033-9b05-4d07-95c7-09f1ad997338.png?v=1763507177"},{"product_id":"copeland-comfort-control-white-rodgers-3l01-170-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L01-170 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 50A55-843\u003c\/strong\u003e is a \u003cstrong\u003euniversal silicon carbide ignition control\u003c\/strong\u003e engineered for high-reliability performance across a broad range of \u003cstrong\u003eHVAC furnace systems\u003c\/strong\u003e. This \u003cstrong\u003eintegrated furnace control board\u003c\/strong\u003e utilizes an onboard microprocessor to provide constant surveillance of the gas burner, inducer motor, and blower fan sequences. Designed as a versatile solution for \u003cstrong\u003efurnace control board replacement\u003c\/strong\u003e, it includes an extensive cross-reference for modules from Trane, York, ICP, and Amana. The \u003cstrong\u003e50A55-843 universal ignition module\u003c\/strong\u003e features built-in \u003cstrong\u003ediagnostic LED indicators\u003c\/strong\u003e to streamline field troubleshooting, allowing technicians to quickly identify system faults through specific flash codes. With selectable \u003cstrong\u003edip switch settings\u003c\/strong\u003e for heat-on and heat-off delays, this board offers the precise timing adjustments required to optimize \u003cstrong\u003efurnace ignition system\u003c\/strong\u003e efficiency and ensure proper heat exchanger cooling. It is fused to protect the low-voltage transformer from field wiring shorts and includes all necessary jumpers and harnesses for simplified integration in the mechanical room.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for the Technician\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Replaces a wide array of White Rodgers 50A50 and 50A55 OEM modules, reducing the need for multiple van stock items.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e The multi-color \u003cstrong\u003ediagnostic LED\u003c\/strong\u003e provides immediate feedback on system status and failure modes, such as pressure switch or lockout issues.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAdaptive Ignition Technology:\u003c\/strong\u003e Employs an intelligent algorithm that manages ignitor warm-up times to maximize the service life of the \u003cstrong\u003esilicon carbide ignitor\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced System Control:\u003c\/strong\u003e Dedicated terminals for 120V accessories including electronic air cleaners and humidifiers, simplifying total system wiring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eField Adjustable Timing:\u003c\/strong\u003e Onboard dip switches allow for onsite customization of blower delays to match specific ductwork and airflow requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions \u0026amp; Technical Support\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs this board compatible with Trane furnaces requiring a jumper?\u003c\/strong\u003e Yes, the 50A55-843 includes a specific jumper wire for Trane applications. If you encounter a \"5 flash\" rollout error code during installation, ensure the RO1 to RO2 jumper is correctly seated.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan this be used with 80V or 120V ignitors?\u003c\/strong\u003e This control is specifically designed for 120V \u003cstrong\u003esilicon carbide ignition\u003c\/strong\u003e systems. Always verify the voltage requirements of the existing ignitor before completing the swap.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat happens if the internal fuse blows?\u003c\/strong\u003e The board features a standard automotive-style 3A fuse. If blown, it typically indicates a short in the 24V thermostat wiring or gas valve circuit that must be cleared before replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643582924,"sku":"3L01-170","price":9.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_86e74fb7-4a3d-40c0-baf6-939932a9b926.png?v=1773615085"},{"product_id":"copeland-comfort-control-white-rodgers-3l01-180-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L01-180 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 3L01-180 Limit Switch\u003c\/strong\u003e is a heavy-duty, 3\/4-inch \u003cstrong\u003esnap disc thermostat\u003c\/strong\u003e designed for high-limit safety and blower control in residential and commercial furnaces. Built by \u003cstrong\u003eCopeland Comfort Control\u003c\/strong\u003e, this SPST (Single Pole Single Throw) switch provides precise thermal regulation with a fixed \u003cstrong\u003e180 degree F cut-out temperature\u003c\/strong\u003e to prevent heat exchanger damage or hazardous overheating. As a professional-grade \u003cstrong\u003efixed temperature limit control\u003c\/strong\u003e, it features an \u003cstrong\u003eopen on rise\u003c\/strong\u003e switch action, meaning it breaks the electrical circuit immediately upon reaching its setpoint to trigger a safety shutdown until the system cools.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for high-cycle reliability, the \u003cstrong\u003e3L01-180\u003c\/strong\u003e includes an \u003cstrong\u003eautomatic reset\u003c\/strong\u003e mechanism that closes the circuit once the ambient temperature drops to the \u003cstrong\u003e140 degree F cut-in\u003c\/strong\u003e threshold. This \u003cstrong\u003eTherm-O-Disc 60T11-610013\u003c\/strong\u003e style control is a standard for many HVACR applications, offering universal airstream mounting via an integral oval flange. It is rated for 10A at 120VAC and 5A at 240VAC under full load conditions, making it a rugged \u003cstrong\u003efurnace limit switch replacement\u003c\/strong\u003e. The package includes tab-to-screw terminal adapters to ensure compatibility with both quick-connect and screw-type wiring harnesses found in the field.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Matches standard 3\/4-inch snap disc footprints, making it the preferred \u003cstrong\u003e60T11-610013\u003c\/strong\u003e replacement across multiple furnace brands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset Logic:\u003c\/strong\u003e Eliminates manual intervention by re-engaging once the temperature differential is met at 140°F.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Safety:\u003c\/strong\u003e High-speed contact separation protects the heat exchanger from high-limit excursions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Ready:\u003c\/strong\u003e Supplied with 1\/4-inch quick-connect terminals and adapters for seamless installation into existing wiring looms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat causes this limit switch to trip repeatedly?\u003c\/strong\u003e Frequent tripping usually indicates restricted airflow due to a dirty filter, failing blower motor, or blocked return vents rather than a faulty switch.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I use this for a fan control application?\u003c\/strong\u003e While \"L\" denotes a \u003cstrong\u003elimit control\u003c\/strong\u003e, the 140°F\/180°F range is often utilized in blower logic; however, always verify the specific \"open on rise\" logic matches your schematic.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow do I test if the snap disc is failing?\u003c\/strong\u003e Use a multimeter to check for continuity at room temperature; since this is \u003cstrong\u003eopen on rise\u003c\/strong\u003e, it should show a closed circuit (continuity) until it reaches 180°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643583692,"sku":"3L01-180","price":8.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_848c669b-d8fd-4769-b47a-fcd35b6b6347.png?v=1756165190"},{"product_id":"copeland-comfort-control-white-rodgers-3l01-350-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L01-350 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L01-350\u003c\/strong\u003e is a high-limit snap disc thermostat engineered for critical thermal protection in HVAC and process heating equipment. As a veteran-grade \u003cstrong\u003e3\/4 inch snap disc limit switch\u003c\/strong\u003e, this component provides a reliable safety interface by interrupting the electrical circuit when temperatures reach the fixed \u003cstrong\u003e350°F cut-out\u003c\/strong\u003e threshold. Its \u003cstrong\u003eopen on rise\u003c\/strong\u003e switch action is a standard safety protocol for furnaces, duct heaters, and specialized appliance applications needing a high-temperature failsafe. Once the environment cools to the \u003cstrong\u003e310°F cut-in\u003c\/strong\u003e point, the internal \u003cstrong\u003eautomatic reset\u003c\/strong\u003e mechanism re-engages the circuit, ensuring continuous system readiness without manual intervention.\u003c\/p\u003e\n\n\u003cp\u003eThis \u003cstrong\u003e60T11-610068 limit control\u003c\/strong\u003e features 1\/4 inch quick-connect terminals and a versatile loose-ring stainless steel mounting bracket for streamlined field replacement. Its rugged aluminum disc cup is designed for rapid thermal response and durability in high-ambient environments up to 350°F. Whether you are servicing a residential furnace or commercial heating unit, use this \u003cstrong\u003eWhite Rodgers 3L01 series\u003c\/strong\u003e switch to maintain precise \u003cstrong\u003efixed temperature regulation\u003c\/strong\u003e and equipment safety standards. Its electrical ratings support a wide range of pilot duty and motor loads, making it a staple for contractors requiring high-performance \u003cstrong\u003eHVAC temperature controls\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFixed Thermal Precision:\u003c\/strong\u003e Factory-set at 350°F (cut-out) and 310°F (cut-in) for consistent safety performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Mounting:\u003c\/strong\u003e Features a loose-ring bracket and 3\/4 inch disc footprint to match standard HVAC mounting holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Electrical Rating:\u003c\/strong\u003e Rated for up to 25A resistive loads and 125 VA pilot duty at 120\/240\/277 VAC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRapid Field Service:\u003c\/strong\u003e Equipped with standard 1\/4 inch tab terminals for fast wire-to-switch connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does 'Open on Rise' mean for this limit switch?\u003c\/strong\u003e\u003cbr\u003e\nThe contacts break the electrical circuit when the temperature climbs to the 350°F set point, effectively shutting down the heating source to prevent overheating.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this switch require a manual reset button?\u003c\/strong\u003e\u003cbr\u003e\nNo, the 3L01-350 is an auto-reset model. It will automatically close the circuit and resume operation once the temperature drops back down to 310°F.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this for fan or blower control?\u003c\/strong\u003e\u003cbr\u003e\nWhile 3L series switches are primarily used as high-limit safety controls, always verify your system's required temperature range. Typically, fan controls utilize 'Close on Rise' action, whereas this unit 'Opens on Rise'.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643587084,"sku":"3L01-350","price":8.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_87abadf2-4b38-40cd-8cd8-eb64994c94d5.png?v=1756165189"},{"product_id":"copeland-comfort-control-white-rodgers-f92-1008-nat-lp-kit","title":"Copeland Comfort Control (White Rodgers) F92-1008 Nat\/LP Kit","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers F92-1008\u003c\/strong\u003e is a professional-grade conversion kit designed specifically for \u003cstrong\u003e36G, 36H, and 36J series 2-stage gas valves\u003c\/strong\u003e. This \u003cstrong\u003enatural gas to liquid propane conversion\u003c\/strong\u003e allows for precise pressure regulation adjustments necessary when transitioning between fuel sources in high-efficiency residential and light commercial furnaces. As a \u003cstrong\u003eWhite Rodgers gas valve conversion kit\u003c\/strong\u003e, it ensures the burner manifold pressure is correctly calibrated for 2-stage operation, maintaining stable combustion across both low and high heat cycles. The kit includes the necessary springs, regulator adjustment components, and labeling required for a code-compliant installation. Technical accuracy is paramount when utilizing the \u003cstrong\u003eF92-1008 LP kit\u003c\/strong\u003e to ensure the \u003cstrong\u003edual-stage gas valve\u003c\/strong\u003e maintains its rated BTU output and prevents soot accumulation or delayed ignition issues. This is a field-essential component for contractors servicing \u003cstrong\u003eCopeland Comfort Control\u003c\/strong\u003e systems where fuel source flexibility is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eCompatible with \u003cstrong\u003e36G, 36H, and 36J 2-stage gas valves\u003c\/strong\u003e for seamless field conversion.\u003c\/li\u003e\n    \u003cli\u003eMaintains accurate \u003cstrong\u003emanifold pressure\u003c\/strong\u003e for consistent fuel delivery across multiple heating stages.\u003c\/li\u003e\n    \u003cli\u003eConstructed to \u003cstrong\u003eOEM specifications\u003c\/strong\u003e to ensure mechanical integrity within the burner assembly.\u003c\/li\u003e\n    \u003cli\u003eSimplifies \u003cstrong\u003eNAT to LP gas conversion\u003c\/strong\u003e without requiring a full valve replacement.\u003c\/li\u003e\n    \u003cli\u003eIncludes specific hardware for \u003cstrong\u003etwo-stage regulation\u003c\/strong\u003e monitoring and adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the F92-1008 be used on single-stage 36G valves?\u003c\/strong\u003e\u003cbr\u003e\nNo, this kit is specifically calibrated for the internal regulator mechanics of \u003cstrong\u003e2-stage White Rodgers valves\u003c\/strong\u003e. Using this on a single-stage valve will result in improper pressure regulation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this kit include the orifice spuds?\u003c\/strong\u003e\u003cbr\u003e\nThis kit focuses on the \u003cstrong\u003egas valve regulator conversion\u003c\/strong\u003e components. You must verify if the specific burner orifices require independent replacement based on the appliance manufacturer's BTU requirements for propane.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the typical pressure setting for this kit?\u003c\/strong\u003e\u003cbr\u003e\nStandard \u003cstrong\u003eLP conversion\u003c\/strong\u003e usually targets 10.0\" W.C. for high stage and approximately 3.5\" to 4.5\" W.C. for low stage, though you must always verify against the furnace rating plate.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643591564,"sku":"F92-1008","price":8.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_2c0e2a22-f238-4697-9146-a6208da4e185.png?v=1756165188"},{"product_id":"copeland-comfort-control-white-rodgers-3f01-200-switch","title":"Copeland Comfort Control (White Rodgers) 3F01-200  Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3F01-200\u003c\/strong\u003e is an industrial-grade \u003cstrong\u003esnap disc fan switch\u003c\/strong\u003e designed for reliable airstream mounting in HVACR systems. This \u003cstrong\u003efixed temperature control\u003c\/strong\u003e features a \u003cstrong\u003eclose on rise switch action\u003c\/strong\u003e, specifically calibrated with a \u003cstrong\u003e200-degree F cut-in\u003c\/strong\u003e and a \u003cstrong\u003e180-degree F cut-out\u003c\/strong\u003e temperature. Engineered as a \u003cstrong\u003eTherm-O-Disc style 60T12 (type 610066)\u003c\/strong\u003e, this \u003cstrong\u003eSPST fan control\u003c\/strong\u003e utilizes an aluminum disc cup for rapid thermal response and a \u003cstrong\u003e3\/4-inch flanged\u003c\/strong\u003e mounting configuration that mirrors standard industry footprints for seamless field replacement. The \u003cstrong\u003eautomatic reset\u003c\/strong\u003e functionality ensures the system returns to its primary state once temperatures drop below the 20-degree differential, maintaining consistent blower operation without manual intervention. Built to handle inductive loads of 5.8A at 120VAC and resistive ratings up to 25A, this component is a staple for contractors requiring a robust \u003cstrong\u003eWhite Rodgers 3F01-200\u003c\/strong\u003e solution for high-limit or blower cycling applications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandardized Fit:\u003c\/strong\u003e Mounting holes are spaced to match existing 3\/4-inch snap disc footprints, reducing installation time for service technicians.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Load Capacity:\u003c\/strong\u003e Rated for up to 25A resistive at 120\/240VAC, making it suitable for a wide range of furnace and appliance blower motors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuick Integration:\u003c\/strong\u003e Features 1\/4-inch quick-connect terminals and includes tab-to-screw adapters for flexible electrical termination in the field.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Thermal Control:\u003c\/strong\u003e The snap-action bimetal disc provides positive, high-speed contact separation to minimize arcing and electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the difference between an \"L\" and \"F\" prefix in White Rodgers controls?\u003c\/strong\u003e In this series, \"F\" stands for Fan (Close on Rise), while \"L\" stands for Limit (Open on Rise). The last three digits (200) signify the cut-in temperature for fan controls.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan this switch be used in a vertical or horizontal orientation?\u003c\/strong\u003e Yes, the 3F01-200 is designed for airstream mounting and functions reliably in any orientation within the plenum or ductwork.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs an adapter plate required for installation?\u003c\/strong\u003e While this unit fits standard 3\/4-inch holes, some legacy applications may require an F6-1798 adapter plate if the existing cutout is larger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643594124,"sku":"3F01-200","price":8.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_e0c49096-687e-4df5-aab9-e15aeee42865.png?v=1756165187"},{"product_id":"copeland-comfort-control-white-rodgers-f92-0656-kit","title":"Copeland Comfort Control (White Rodgers) F92-0656 Kit","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) F92-0656 Kit\u003c\/strong\u003e is a field-proven \u003cstrong\u003eLP to natural gas conversion kit\u003c\/strong\u003e engineered for seamless integration with White Rodgers series 36C, 36D, 36E, 36F, and 36G gas valves. As a veteran technician, you know that maintaining precise \u003cstrong\u003emanifold pressure\u003c\/strong\u003e is critical for combustion stability. This kit includes a high-grade \u003cstrong\u003egas valve regulator spring\u003c\/strong\u003e designed to calibrate the outlet pressure within the standard 2.5\" to 5.0\" W.C. range for natural gas applications. Unlike generic alternatives, this \u003cstrong\u003eOEM conversion kit\u003c\/strong\u003e preserves the integrity of the \u003cstrong\u003efurnace gas valve\u003c\/strong\u003e and ensures high-efficiency performance after transitioning from liquid propane. The package comes complete with the necessary regulator adjustment components and conversion labeling required for code compliance. Whether you are servicing a fast-open or slow-open model, the \u003cstrong\u003eWhite Rodgers F92-0656\u003c\/strong\u003e provides the mechanical reliability needed for a professional-grade \u003cstrong\u003egas valve conversion\u003c\/strong\u003e without compromising safety or throughput.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefit List:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Specifically designed for \u003cstrong\u003eWhite Rodgers 36C, 36D, 36E, 36F, and 36G\u003c\/strong\u003e series valves, ensuring a perfect fit without field modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Regulation:\u003c\/strong\u003e The included \u003cstrong\u003eregulator spring\u003c\/strong\u003e allows for accurate adjustment of \u003cstrong\u003enatural gas pressure\u003c\/strong\u003e between 2.5\" and 5\" W.C.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Replacement Set:\u003c\/strong\u003e Includes the regulator spring, adjustment screw, and required \u003cstrong\u003econversion stickers\u003c\/strong\u003e for clear identification and safety compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial Grade Reliability:\u003c\/strong\u003e Built to \u003cstrong\u003eCopeland Comfort Control\u003c\/strong\u003e standards, maintaining the specific flow characteristics required for peak furnace efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan this kit be used for high-altitude conversions?\u003c\/strong\u003e This kit is intended for standard altitude adjustments; high-altitude applications may require additional orifice resizing per the appliance manufacturer's specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs this kit compatible with two-stage valves?\u003c\/strong\u003e The F92-0656 is primary designed for \u003cstrong\u003esingle-stage gas valves\u003c\/strong\u003e; always verify the specific model dash number on your 36G or 36H valve before installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes this include burner orifices?\u003c\/strong\u003e No, this \u003cstrong\u003econversion kit\u003c\/strong\u003e focuses on the \u003cstrong\u003egas valve regulator\u003c\/strong\u003e. Burner orifices must be sourced separately based on the BTU rating of the appliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643600396,"sku":"F92-0656","price":10.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_79b1d956-cc17-4435-aea8-4fd173c7dca3.png?v=1756165186"},{"product_id":"cooper-bussmann-ecnr50-fuse","title":"Cooper Bussmann ECNR50 Fuse","description":"\u003cp\u003eThe \u003cstrong\u003eCooper Bussmann ECNR50\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003eClass RK5 dual-element fuse\u003c\/strong\u003e designed for high-performance circuit protection in demanding HVACR environments. This 50-amp, 250V \u003cstrong\u003etime-delay cartridge fuse\u003c\/strong\u003e is specifically engineered to handle the inductive loads of compressors and motors, providing a 10-second minimum time lag at 500% of the rated current. This dual-element construction effectively prevents nuisance blowing caused by temporary \u003cstrong\u003emotor starting currents\u003c\/strong\u003e or harmless surges while maintaining a secondary element for rapid \u003cstrong\u003eshort-circuit protection\u003c\/strong\u003e up to 200,000 RMS symmetrical amperes.\n\nFor those in the field, sizing this \u003cstrong\u003eBussmann Fusetron\u003c\/strong\u003e at approximately 125% of the motor's full-load amperes (FLA) ensures robust \u003cstrong\u003emotor overload protection\u003c\/strong\u003e against burnout and single-phasing. The ECNR50 operates at lower temperatures than standard one-time fuses, reducing thermal stress on switches and panels. Its rejection-type design ensures safety by preventing the installation of fuses with lower interrupting ratings in \u003cstrong\u003eClass R fuse blocks\u003c\/strong\u003e. With a standard 3-inch length and 13\/16-inch diameter, it serves as a direct, high-reliability upgrade for existing power distribution mains and branch circuits.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDual-element technology\u003c\/strong\u003e provides superior overload and cycling capabilities for heavy-duty HVAC motors.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLong time-delay\u003c\/strong\u003e characteristic eliminates downtime from nuisance trips during compressor startup.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIncreased safety\u003c\/strong\u003e via 200kA interrupting rating, significantly higher than standard Class K fuses.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCooler operation\u003c\/strong\u003e minimizes heat damage to lugs and internal panel components.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRejection-style tips\u003c\/strong\u003e prevent improper fuse substitution in critical safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use an ECNR50 to replace a standard 50-amp non-time-delay fuse?\u003c\/strong\u003e\u003cbr\u003e\nYes, as long as the voltage and physical dimensions align. The ECNR50 is a \u003cstrong\u003eClass RK5 fuse\u003c\/strong\u003e, which provides better protection for inductive loads like motors compared to fast-acting alternatives.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between ECNR and FRN-R fuses?\u003c\/strong\u003e\u003cbr\u003e\nWhile both are \u003cstrong\u003e250V Class RK5 fuses\u003c\/strong\u003e, ECNR is often used in Edison-branded or specific Cooper Bussmann series distribution. They are functionally interchangeable for most HVACR applications requiring \u003cstrong\u003etime-delay protection\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is my ECNR50 still blowing during motor startup?\u003c\/strong\u003e\u003cbr\u003e\nEnsure the fuse is sized to roughly 125% of the motor's running current. If it continues to blow, verify there is no \u003cstrong\u003esingle-phasing\u003c\/strong\u003e condition or mechanical binding in the motor or compressor.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Cooper Bussmann","offers":[{"title":"Default Title","offer_id":35643606220,"sku":"ECNR50","price":6.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_b1507e2b-eed7-4e46-834c-f49abd86ddfb.jpg?v=1666726469"},{"product_id":"copeland-comfort-control-white-rodgers-f92-0659-lp-kit","title":"Copeland Comfort Control (White Rodgers) F92-0659 LP Kit","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) F92-0659 LP Kit\u003c\/strong\u003e is a professional-grade solution for converting \u003cstrong\u003enatural gas valves\u003c\/strong\u003e to \u003cstrong\u003eregulated liquid propane (LP)\u003c\/strong\u003e operation. Designed for high-performance field conversions, this kit is specifically engineered for use with \u003cstrong\u003esingle-stage 36C, 36D, 36E, 36F, and 36G series gas valves\u003c\/strong\u003e. It provides a reliable \u003cstrong\u003eregulation range of 7.0\" to 12.0\" W.C.\u003c\/strong\u003e, ensuring consistent manifold pressure for LP applications. As an \u003cstrong\u003eOEM conversion kit\u003c\/strong\u003e, it includes the necessary \u003cstrong\u003eLP regulator spring\u003c\/strong\u003e, adjustment screw, and required \u003cstrong\u003ewarning labels\u003c\/strong\u003e to maintain appliance safety and compliance after the \u003cstrong\u003eorifice and spring change\u003c\/strong\u003e. For technicians servicing White Rodgers systems, this \u003cstrong\u003edirect replacement kit\u003c\/strong\u003e eliminates guesswork in the field, facilitating a \u003cstrong\u003eseamless gas type transition\u003c\/strong\u003e while maintaining the integrity of the original \u003cstrong\u003e36 series valve\u003c\/strong\u003e body. This kit is essential for adapting residential and light commercial heating equipment for \u003cstrong\u003epropane gas\u003c\/strong\u003e usage in areas without natural gas infrastructure.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Validated for use across the entire \u003cstrong\u003eWhite Rodgers 36C, 36D, 36E, 36F, and 36G\u003c\/strong\u003e valve families.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Regulation:\u003c\/strong\u003e Maintains stable \u003cstrong\u003eLP manifold pressure\u003c\/strong\u003e between 7.5\" and 12.0\" W.C. for optimal burner efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete Package:\u003c\/strong\u003e Includes the \u003cstrong\u003estainless steel regulator spring\u003c\/strong\u003e, conversion plate, and adhesive labels for code compliance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOEM Standards:\u003c\/strong\u003e Manufactured by \u003cstrong\u003eCopeland\/Emerson\u003c\/strong\u003e to ensure exact fitment and factory-spec flow characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this kit on a two-stage 36G valve?\u003c\/strong\u003e\u003cbr\u003e\nNo, the \u003cstrong\u003eF92-0659\u003c\/strong\u003e is specifically designed for \u003cstrong\u003esingle-stage gas valves\u003c\/strong\u003e. Two-stage valves require a different conversion kit tailored for high and low-fire regulation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this kit include burner orifices?\u003c\/strong\u003e\u003cbr\u003e\nThis is a \u003cstrong\u003egas valve regulator conversion kit\u003c\/strong\u003e. While it handles the valve’s pressure regulation, you must still source the correct \u003cstrong\u003edrill-size burner orifices\u003c\/strong\u003e based on the appliance manufacturer's BTU rating.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this kit reversible?\u003c\/strong\u003e\u003cbr\u003e\nYes, the valve can be converted back to natural gas by swapping the \u003cstrong\u003eLP spring\u003c\/strong\u003e back to the original \u003cstrong\u003enatural gas spring\u003c\/strong\u003e and readjusting the pressure to 3.5\" W.C.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643609548,"sku":"F92-0659","price":9.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_8f8d761c-6c64-47ec-ab41-f0916e3f5ae6.png?v=1756165185"},{"product_id":"copeland-comfort-control-white-rodgers-90-360-relay","title":"Copeland Comfort Control (White Rodgers) 90-360 Relay","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 90-360\u003c\/strong\u003e, also identified as the \u003cstrong\u003eCopeland 440-543-000\u003c\/strong\u003e, is a heavy-duty \u003cstrong\u003e24V SPNO general purpose relay\u003c\/strong\u003e designed for reliable switching in HVACR applications. This \u003cstrong\u003esingle pole normally open relay\u003c\/strong\u003e features \u003cstrong\u003e1\/4-inch quick connect terminals\u003c\/strong\u003e and a low-draw \u003cstrong\u003e24V coil\u003c\/strong\u003e, making it a standard solution for controlling \u003cstrong\u003econdenser fan motors\u003c\/strong\u003e, \u003cstrong\u003eelectric heating elements\u003c\/strong\u003e, and \u003cstrong\u003eindustrial automation circuits\u003c\/strong\u003e. Engineered for \u003cstrong\u003elong-cycle durability\u003c\/strong\u003e, the \u003cstrong\u003e90-360 relay\u003c\/strong\u003e serves as a direct \u003cstrong\u003eOEM replacement\u003c\/strong\u003e for various universal applications, ensuring seamless \u003cstrong\u003eelectrical system integration\u003c\/strong\u003e. Its \u003cstrong\u003ecompact footprint\u003c\/strong\u003e allows for installation in tight \u003cstrong\u003econtrol panels\u003c\/strong\u003e and \u003cstrong\u003eHVAC electrical closets\u003c\/strong\u003e where space is at a premium.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Interchanges directly with \u003cstrong\u003e440-543-000\u003c\/strong\u003e and common \u003cstrong\u003e24V SPNO power relays\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Build:\u003c\/strong\u003e Features \u003cstrong\u003enon-position sensitive mounting\u003c\/strong\u003e for easy retrofitting into existing \u003cstrong\u003econtactor enclosures\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Load Capacity:\u003c\/strong\u003e Rated for \u003cstrong\u003eheavy-duty switching\u003c\/strong\u003e of inductive and resistive loads in \u003cstrong\u003erefrigeration systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Efficiency:\u003c\/strong\u003e Minimized \u003cstrong\u003ecoil power consumption\u003c\/strong\u003e reduces heat generation within the \u003cstrong\u003econtrol board\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the contact ratings for the 90-360?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003eHVAC relay\u003c\/strong\u003e typically handles a \u003cstrong\u003e12A Full Load Amperage (FLA)\u003c\/strong\u003e at 125VAC and 6A FLA at 250VAC, providing a robust solution for \u003cstrong\u003eline voltage switching\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 90-360 non-position sensitive?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e90-360 relay\u003c\/strong\u003e can be mounted in any orientation without affecting the integrity of the \u003cstrong\u003emagnetic coil\u003c\/strong\u003e or \u003cstrong\u003econtact closing\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this replace a Double Pole Single Throw (DPST) relay?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is a \u003cstrong\u003eSingle Pole Normally Open\u003c\/strong\u003e (SPNO) relay. Always verify your \u003cstrong\u003ewiring schematic\u003c\/strong\u003e to ensure \u003cstrong\u003eamperage ratings\u003c\/strong\u003e and \u003cstrong\u003epole configuration\u003c\/strong\u003e match your specific \u003cstrong\u003efurnace\u003c\/strong\u003e or \u003cstrong\u003eA\/C unit\u003c\/strong\u003e requirements.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643626508,"sku":"90-360","price":9.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_6b6beb99-0ace-4aa5-9d59-5aed5d747b49.png?v=1756165184"},{"product_id":"copeland-comfort-control-white-rodgers-90-370-fan-relay","title":"Copeland Comfort Control (White Rodgers) 90-370 Fan Relay","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 90-370 Fan Relay\u003c\/strong\u003e is a heavy-duty, \u003cstrong\u003eSPDT (Single Pole Double Throw)\u003c\/strong\u003e switching solution designed for high-demand HVACR applications. Operating on a \u003cstrong\u003e24V coil\u003c\/strong\u003e (50\/60 Hz), this \u003cstrong\u003eenclosed fan relay\u003c\/strong\u003e provides reliable control for fan motors, solenoids, and general-purpose switching in both heating and cooling systems. Technical specifications include a 77-ohm DC resistance coil and a contact rating of 12A continuous at 125 VAC (60A inrush). Its compact, totally enclosed design protects internal components from environmental debris, ensuring consistent performance in any mounting position.\u003c\/p\u003e\n\n\u003cp\u003eAs a \u003cstrong\u003edirect replacement for 42-25104-06\u003c\/strong\u003e, the 90-370 is a critical \u003cstrong\u003eHVAC replacement part\u003c\/strong\u003e for Rheem, Ruud, and various RBM-style Type 184 relays. The unit features 1\/4-inch male quick-connect terminals for streamlined field installation. With a resistive rating of up to 25A at 277 VAC, it is engineered to handle the inductive loads typical of residential and light commercial air handlers and furnaces.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Serves as a \u003cstrong\u003e90-370 crossover\u003c\/strong\u003e for 42-25104-06, 90370Q, and numerous OEM fan control relays.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Durability:\u003c\/strong\u003e The \u003cstrong\u003etotally enclosed relay\u003c\/strong\u003e housing prevents contact contamination in dusty furnace environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Flexibility:\u003c\/strong\u003e Designed for multi-position mounting with semi-universal tabs to fit tight control voltage cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Switching:\u003c\/strong\u003e Features \u003cstrong\u003eSPDT contacts\u003c\/strong\u003e for versatile normally open (NO) and normally closed (NC) operational logic.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTechnical Precision:\u003c\/strong\u003e Low-power consumption 24VAC coil (3VA sealed, 4VA inrush) prevents overloading control transformers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 90-370 a direct substitute for the Rheem 42-25104-06?\u003c\/strong\u003e\u003cbr\u003e\nYes, the 90-370 is the industry-standard direct replacement for the 42-25104-06, featuring matching mounting footprints and electrical contact ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between SPDT and SPST in fan relays?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eSPDT fan relay\u003c\/strong\u003e provides a common terminal that switches between two distinct paths (NO and NC), whereas an SPST only offers a single on\/off path. This makes the 90-370 more versatile for multi-speed fan control.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I wire the White Rodgers 90-370?\u003c\/strong\u003e\u003cbr\u003e\nTypically, terminals 1 and 3 are for the 24V coil. Terminals 2, 4, and 5 represent the SPDT switch contacts. Always refer to the specific \u003cstrong\u003e90-370 wiring diagram\u003c\/strong\u003e printed on the relay casing or your equipment manufacturer’s schematic.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643695500,"sku":"90-370","price":11.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_175034dc-16a8-42ad-aac9-d80bf613d888.png?v=1756165184"},{"product_id":"copeland-comfort-control-white-rodgers-90-341-relay","title":"Copeland Comfort Control (White Rodgers) 90-341 Relay","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 90-341 Relay\u003c\/strong\u003e is a heavy-duty, semi-enclosed \u003cstrong\u003e2PDT 120V power relay\u003c\/strong\u003e engineered for reliable switching in HVACR systems, appliances, and fan control centers. As a \u003cstrong\u003eType 91 relay\u003c\/strong\u003e, this unit features a \u003cstrong\u003e120VAC coil\u003c\/strong\u003e with a 420 Ohm DC resistance and is designed for continuous duty cycles. The \u003cstrong\u003edouble pole double throw (DPDT)\u003c\/strong\u003e configuration provides two sets of \u003cstrong\u003epower-rated contacts\u003c\/strong\u003e, making it a versatile \u003cstrong\u003eHVAC switching relay\u003c\/strong\u003e for handling inductive loads. With 1\/4-inch \u003cstrong\u003equick-connect terminals\u003c\/strong\u003e, it simplifies field replacements for contractors working on air handlers and vending machines.\u003c\/p\u003e\n\u003cp\u003eBuilt for durability in demanding environments, the \u003cstrong\u003eEmerson 90-341\u003c\/strong\u003e operates within a temperature range of -40°F to 130°F. It is a direct \u003cstrong\u003eCopeland Comfort Control (White Rodgers)\u003c\/strong\u003e\u003cstrong\u003e 90-341 cross reference\u003c\/strong\u003e for common industry parts, including the \u003cstrong\u003eHoneywell R4222D1013\u003c\/strong\u003e and Mars 90341. Whether you are managing a \u003cstrong\u003efan motor relay\u003c\/strong\u003e replacement or a general-purpose electrical load, this \u003cstrong\u003e120V 2PDT relay\u003c\/strong\u003e delivers 12 FLA at 125VAC and 6 FLA at 250VAC, ensuring consistent performance across high-cycle applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Serves as a standard \u003cstrong\u003eType 91 relay\u003c\/strong\u003e replacement for major brands like Honeywell, Mars, and Packard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Load Capacity:\u003c\/strong\u003e Features \u003cstrong\u003epower-rated contacts\u003c\/strong\u003e capable of handling up to 15A resistive at 277VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplified Wiring:\u003c\/strong\u003e Equipped with industry-standard 1\/4-inch \u003cstrong\u003equick-connect terminals\u003c\/strong\u003e for fast installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Performance:\u003c\/strong\u003e Designed for \u003cstrong\u003econtinuous duty\u003c\/strong\u003e with a mechanical life of up to 1,000,000 operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the coil voltage for the Copeland Comfort Control (White Rodgers) 90-341?\u003c\/strong\u003e\u003cbr\u003eThis relay is equipped with a \u003cstrong\u003e120VAC coil\u003c\/strong\u003e (rated for 110-120V) at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this relay to replace a Honeywell R4222D1013?\u003c\/strong\u003e\u003cbr\u003eYes, the \u003cstrong\u003eWhite-Rodgers 90-341\u003c\/strong\u003e is a functional equivalent and a common \u003cstrong\u003ecross reference\u003c\/strong\u003e for the R4222D1013.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the contact ratings for this 2PDT relay?\u003c\/strong\u003e\u003cbr\u003eThe contacts are rated for 12 FLA \/ 60 LRA at 125VAC and 6 FLA \/ 35 LRA at 250VAC.\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643785996,"sku":"90-341","price":12.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_873125fc-f2db-4569-a690-7098f75801b3.png?v=1684799266"},{"product_id":"copeland-comfort-control-white-rodgers-90-244-contactor","title":"Copeland Comfort Control (White Rodgers) 90-244 Contactor","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 90-244 Contactor\u003c\/strong\u003e is a heavy-duty, 2-pole definite purpose component engineered for high-demand HVAC and refrigeration applications. Rated for \u003cstrong\u003e30 Amp inductive\u003c\/strong\u003e and 40 Amp resistive loads, this unit features a \u003cstrong\u003e24V AC coil\u003c\/strong\u003e optimized for cooler operation and extended component life. The \u003cstrong\u003eDPST-NO configuration\u003c\/strong\u003e with double break contacts ensures a positive make and break, reducing the risk of pitting or welding under high-cycle conditions. Designed for versatility, it includes a \u003cstrong\u003euniversal mounting bracket\u003c\/strong\u003e and multi-point terminal options, including screw terminals and \u003cstrong\u003equad 1\/4 inch quick connects\u003c\/strong\u003e, making it a drop-in replacement for standard air conditioning and heating contactors.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Coil Performance:\u003c\/strong\u003e Features a low VA coil (6 VA nominal, 32 VA inrush) that maintains a lower operating temperature to prevent premature breakdown.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e The \u003cstrong\u003estandard 2-pole footprint\u003c\/strong\u003e and multi-hole mounting plate allow for easy integration into most residential and light commercial condensing units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Precision-manufactured to minimize mechanical chatter and hum during continuous duty operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built with silver alloy contacts and high-grade insulating resin to withstand ambient temperatures up to 150°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 90-244 compatible with 120V or 240V control circuits?\u003c\/strong\u003e\u003cbr\u003e\nNo, the \u003cstrong\u003eWhite Rodgers 90-244\u003c\/strong\u003e is specifically designed for 24V AC control circuits. Using it with higher voltage control signals will result in immediate coil failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this 30 Amp contactor to replace a 25 Amp model?\u003c\/strong\u003e\u003cbr\u003e\nYes, as an \u003cstrong\u003eHVAC technician\u003c\/strong\u003e, you can safely upgrade a 25 Amp contactor to this \u003cstrong\u003e30 Amp rated\u003c\/strong\u003e unit, provided the physical dimensions and coil voltage match. Higher amperage ratings offer more robust handling for the compressor and fan loads.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat wiring terminals are available on this unit?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003edefinite purpose contactor\u003c\/strong\u003e features flexible termination including screw terminals and double 1\/4\" quick connects on each pole to accommodate various lead configurations.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643817420,"sku":"90-244","price":17.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_83294fd1-500a-4e10-b6d0-3e3975f0357c.png?v=1756165183"},{"product_id":"copeland-comfort-control-white-rodgers-f92-0228-seal-kit","title":"Copeland Comfort Control (White Rodgers) F92-0228 Seal Kit","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers F92-0228 Seal Kit\u003c\/strong\u003e is a field-serviceable solution designed specifically for 1-inch 1300 series hydronic zone valves. As a direct \u003cstrong\u003eOEM replacement water seal kit\u003c\/strong\u003e, it provides the necessary internal components to address leaks at the valve stem, preventing moisture damage to the actuator or surrounding boiler components. This kit is engineered for compatibility with 1-inch models, including the \u003cstrong\u003e1311-103\u003c\/strong\u003e, \u003cstrong\u003e1311-132\u003c\/strong\u003e, \u003cstrong\u003e1315-103\u003c\/strong\u003e, \u003cstrong\u003e1361-103\u003c\/strong\u003e, and 1361-132. Utilizing high-grade elastomers, the \u003cstrong\u003eF92-0228\u003c\/strong\u003e ensures a reliable seal under standard \u003cstrong\u003ehydronic heating system\u003c\/strong\u003e pressures and temperatures. For technicians performing \u003cstrong\u003ezone valve maintenance\u003c\/strong\u003e, this kit contains a quad ring, O-ring, Tru-Arc ring, and cotter pin, allowing for a complete rebuild of the sealing assembly without needing to replace the entire \u003cstrong\u003eWhite Rodgers zone valve\u003c\/strong\u003e body. Ensuring a precise fit for 1-inch assemblies, this kit is essential for restoring system integrity and maintaining loop isolation in residential and commercial hydronic applications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise OEM Fit:\u003c\/strong\u003e Specifically manufactured for 1\" 1311 and 1361 series valves to ensure leak-free performance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Rebuild:\u003c\/strong\u003e Includes the quad ring, O-ring, Tru-Arc ring, and cotter pin for a professional-grade repair.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Protection:\u003c\/strong\u003e Stops active stem leaks that can lead to electrical failure in the power head or motor assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHydronic Compatibility:\u003c\/strong\u003e Rated for standard water-based heating loops and glycol-mix systems often found in hydronic installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhich valves is the F92-0228 compatible with?\u003c\/strong\u003e This kit is designed for 1-inch 1311 and 1361 series zone valves. If you are servicing 3\/4-inch or 1-1\/4-inch valves, you will need part numbers F92-0227 or F92-0229, respectively.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I use this kit to fix a buzzing motor?\u003c\/strong\u003e No. While this kit fixes water leaks, a buzzing or failing motor typically requires an F19-0097 (3-wire) or F19-0104 (2-wire) motor replacement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes this include the instructions?\u003c\/strong\u003e Yes, these kits typically include technical guidance for the removal of the Tru-Arc ring and the replacement of the internal seals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643835276,"sku":"F92-0228","price":13.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_49d179db-a1ae-4595-a710-042a4c79a071.jpg?v=1756165181"},{"product_id":"copeland-comfort-control-white-rodgers-90-245-contactor","title":"Copeland Comfort Control (White Rodgers) 90-245 Contactor","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control 90-245 Contactor\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003e2-pole 30A contactor\u003c\/strong\u003e engineered for rigorous switching in commercial and residential HVACR applications. As the \u003cstrong\u003edirect replacement for White Rodgers 90-232\u003c\/strong\u003e, this unit facilitates seamless field service without requiring mounting modifications. It features a \u003cstrong\u003e120V AC coil\u003c\/strong\u003e with a DC resistance of 224 Ohms and a low nominal current draw of 50 mA, ensuring efficient coil engagement and reduced heat generation. With specific ratings for \u003cstrong\u003eup to 32 VA inrush\u003c\/strong\u003e and 6 VA nominal, the \u003cstrong\u003e90-245 contactor\u003c\/strong\u003e provides stable operation for air conditioning condensers, heat pump systems, and auxiliary heating circuits. This \u003cstrong\u003eWhite Rodgers 120V HVAC contactor\u003c\/strong\u003e is built with silver cadmium oxide contacts for superior arc resistance and high-integrity terminal connections to withstand heavy-duty cycles in demanding environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Contractors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Specifically designed to replace the \u003cstrong\u003e90-232 contactor\u003c\/strong\u003e, eliminating the need for complex rewiring or bracket adjustments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Amperage Capacity:\u003c\/strong\u003e Rated for 30A inductive loads, making it ideal for standard residential and light commercial compressor switching.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced Coil Efficiency:\u003c\/strong\u003e The \u003cstrong\u003e120V 2-pole contactor\u003c\/strong\u003e design optimizes power consumption with a low 50 mA current draw.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile Compatibility:\u003c\/strong\u003e Compatible with a wide range of Copeland and White Rodgers controlled heating and cooling equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIndustry Standard Performance:\u003c\/strong\u003e Handles high inrush currents typical of inductive motor starts without premature contact pitting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 90-245 a direct fit for the 90-232?\u003c\/strong\u003e\u003cbr\u003e\nYes, this is the official manufacturer-designated \u003cstrong\u003e90-245 replacement for 90-232\u003c\/strong\u003e, maintaining the same electrical ratings and footprint.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this contactor be used in 240V systems?\u003c\/strong\u003e\u003cbr\u003e\nWhile the \u003cstrong\u003e30A 2-pole contacts\u003c\/strong\u003e can switch 240V loads, the \u003cstrong\u003ecoil voltage is 120V\u003c\/strong\u003e. Ensure your control circuit provides 120V to the coil terminals before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the FLA and LRA ratings?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eCopeland 90-245\u003c\/strong\u003e is typically rated for 30 Full Load Amps (FLA) and up to 150 Locked Rotor Amps (LRA) at 240V, meeting standard specifications for most 1.5 to 5-ton AC units.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643864716,"sku":"90-245","price":17.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_d426cdcb-4318-4932-a0f1-6401ca7fe5e1.png?v=1771538400"},{"product_id":"copeland-comfort-control-white-rodgers-3l02-200-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L02-200 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L02-200 Limit Switch\u003c\/strong\u003e is a high-limit safety control engineered for precise temperature regulation in residential and commercial HVAC systems. This \u003cstrong\u003esnap disc manual reset\u003c\/strong\u003e switch is rated for a \u003cstrong\u003e200°F fixed cut-out\u003c\/strong\u003e and utilizes an \u003cstrong\u003eopen on rise\u003c\/strong\u003e switch action to prevent equipment overheating. As a direct \u003cstrong\u003e460-500-000 replacement\u003c\/strong\u003e, it is frequently used by technicians for flanged airstream mounting in air handlers and furnaces. The \u003cstrong\u003eSPST operation\u003c\/strong\u003e ensures reliable electrical interruption with a motor full load rating of 10A at 120VAC and 5A at 240VAC. Built for durability, this \u003cstrong\u003emanual reset limit switch\u003c\/strong\u003e serves as a critical safety component to protect blowers and heat exchangers from thermal damage. When troubleshooting a \u003cstrong\u003ehigh limit switch tripped\u003c\/strong\u003e condition, this OEM-quality component provides the exact thermal response required for safe system resumption following a manual override.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Contractors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eUniversal \u003cstrong\u003eflanged airstream mount\u003c\/strong\u003e design allows for versatile installation in various duct and plenum configurations.\u003c\/li\u003e\n    \u003cli\u003eStandardized \u003cstrong\u003e3L02-200\u003c\/strong\u003e specifications provide a drop-in solution for legacy \u003cstrong\u003eWhite Rodgers 60T15-330538\u003c\/strong\u003e controls.\u003c\/li\u003e\n    \u003cli\u003eHigh-temperature \u003cstrong\u003e200-degree fixed cut-out\u003c\/strong\u003e protects heat exchangers from cracking due to airflow restrictions.\u003c\/li\u003e\n    \u003cli\u003eManual reset mechanism ensures technicians must inspect the system before restarting, enhancing overall safety.\u003c\/li\u003e\n    \u003cli\u003eCompatible with \u003cstrong\u003epilot duty\u003c\/strong\u003e circuits up to 125 VA at 120\/240\/277 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 3L02-200 as an automatic reset switch?\u003c\/strong\u003e\u003cbr\u003e\nNo. This is a \u003cstrong\u003emanual reset limit switch\u003c\/strong\u003e. For safety reasons, it requires a physical button press to close the circuit after a 200°F trip occurs, ensuring the cause of the overheat is addressed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I verify if my current 460-500-000 is failing?\u003c\/strong\u003e\u003cbr\u003e\nCheck for continuity across the terminals when the system is cool. If the circuit is open at room temperature and the manual reset button is depressed, the internal snap disc or \u003cstrong\u003eSPST\u003c\/strong\u003e contacts may be compromised.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the proper mounting orientation for this limit control?\u003c\/strong\u003e\u003cbr\u003e\nThe flanged mount is designed for \u003cstrong\u003eairstream\u003c\/strong\u003e sensing. Ensure the disc is positioned directly in the path of the air to accurately monitor the \u003cstrong\u003ehigh limit\u003c\/strong\u003e temperature threshold.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643867660,"sku":"3L02-200","price":13.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_77b3c9c7-7f77-41af-86f9-294222be34a7.png?v=1756165180"},{"product_id":"copeland-020-0600-00-gasket","title":"Copeland 020-0600-00 Gasket","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland 020-0600-00 Cylinder Head Gasket\u003c\/strong\u003e is a critical sealing component engineered specifically for high-pressure refrigeration environments. Designed for seamless integration with \u003cstrong\u003eCopeland 4D, 6D, and 8D series compressors\u003c\/strong\u003e, this OEM-spec gasket ensures a robust, gas-tight interface between the cylinder head and the compressor block. Utilizing advanced materials capable of withstanding extreme thermal cycling and discharge temperatures, the \u003cstrong\u003e020-0600-00\u003c\/strong\u003e prevents internal bypass and external refrigerant leaks, maintaining the volumetric efficiency of your \u003cstrong\u003esemi-hermetic compressor\u003c\/strong\u003e. For technicians performing a \u003cstrong\u003evalve plate replacement\u003c\/strong\u003e or top-end overhaul, replacing the \u003cstrong\u003ecompressor head gasket\u003c\/strong\u003e is mandatory to prevent pressure loss and potential oil contamination. This \u003cstrong\u003eindustrial refrigeration gasket\u003c\/strong\u003e provides the precision fit required to meet original manufacturer torque specifications, ensuring reliable performance in demanding commercial HVACR applications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for the Contractor:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise OEM Compatibility:\u003c\/strong\u003e Engineered specifically for \u003cstrong\u003eCopeland 4D, 6D, and 8D\u003c\/strong\u003e compressor models to ensure exact bolt-hole alignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Pressure Integrity:\u003c\/strong\u003e Designed to maintain a reliable seal under rigorous discharge pressures, preventing costly \u003cstrong\u003erefrigerant leaks\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Stability:\u003c\/strong\u003e Constructed from high-grade materials that resist degradation during high-temperature operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Efficiency:\u003c\/strong\u003e Eliminates gas blow-by between cylinders to optimize \u003cstrong\u003erefrigerant compression\u003c\/strong\u003e and system cooling capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should the Copeland 020-0600-00 gasket be replaced?\u003c\/strong\u003e\u003cbr\u003e\nThis gasket must be replaced every time the cylinder head is removed for service, such as during valve plate inspections or reed valve repairs, to ensure a fresh, reliable seal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this gasket compatible with all 4D series compressors?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e020-0600-00\u003c\/strong\u003e is the standard \u003cstrong\u003ecylinder head gasket\u003c\/strong\u003e for 4D, 6D, and 8D series semi-hermetic units. Always verify your specific model number against the parts manual for exact fitment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes a head gasket to fail in a Copeland compressor?\u003c\/strong\u003e\u003cbr\u003e\nCommon causes include liquid slugging, overheating due to high compression ratios, or improper torque during previous head installations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland","offers":[{"title":"Default Title","offer_id":35643923212,"sku":"020-0600-00","price":17.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_285817bd-15ea-47c6-9f36-3626bf163d37.png?v=1756165180"},{"product_id":"copeland-comfort-control-alco-059261-cable-assembly","title":"Copeland Comfort Control (Alco) 059261 Cable Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (Alco) 059261\u003c\/strong\u003e (part number \u003cstrong\u003eX-28616\u003c\/strong\u003e) is a precision-engineered \u003cstrong\u003eDIN connector cable assembly\u003c\/strong\u003e specifically designed for \u003cstrong\u003eASC2x type solenoid coils\u003c\/strong\u003e. As a critical link in the electrical control circuit of high-performance HVACR systems, this assembly ensures a stable and moisture-resistant connection between the power source and the solenoid valve. Built for the rigors of commercial refrigeration and industrial air conditioning, the \u003cstrong\u003e059261 cable assembly\u003c\/strong\u003e features a robust \u003cstrong\u003eDIN plug \u003c\/strong\u003e design that simplifies field installation and maintenance, allowing for a secure \"plug-and-play\" interface with \u003cstrong\u003eCopeland Comfort Control (Alco)\u003c\/strong\u003e\u003cstrong\u003e Controls\u003c\/strong\u003e hardware.\u003c\/p\u003e\n\u003cp\u003eFor technicians servicing \u003cstrong\u003erefrigeration solenoid valves\u003c\/strong\u003e, utilizing an OEM-spec \u003cstrong\u003eX-28616 connector\u003c\/strong\u003e is essential to prevent voltage drops or intermittent coil failure. This assembly is optimized for \u003cstrong\u003eHVAC solenoid coil electrical connections\u003c\/strong\u003e, providing the necessary strain relief and environmental protection required for continuous duty applications. Whether you are replacing a worn lead or performing a new install on an \u003cstrong\u003eASC2 solenoid coil\u003c\/strong\u003e, this \u003cstrong\u003ecable assembly\u003c\/strong\u003e delivers the reliability demanded by professional contractors to maintain system uptime and prevent expensive diagnostic call-backs caused by poor electrical continuity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned exclusively for seamless integration with \u003cstrong\u003eCopeland Comfort Control (Alco) \u003c\/strong\u003e\u003cstrong\u003eASC2x series coils\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eStandardized \u003cstrong\u003eDIN connector\u003c\/strong\u003e interface ensures a secure, vibration-resistant electrical contact.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty \u003cstrong\u003eX-28616 cable\u003c\/strong\u003e construction provides durable protection against oil, heat, and environmental contaminants.\u003c\/li\u003e\n\u003cli\u003eSimplifies \u003cstrong\u003esolenoid coil wiring\u003c\/strong\u003e with a dedicated plug-in design, reducing service time during valve maintenance.\u003c\/li\u003e\n\u003cli\u003eEnsures consistent amperage delivery to the \u003cstrong\u003esolenoid actuator\u003c\/strong\u003e for reliable valve cycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 059261 assembly compatible with other coil types?\u003c\/strong\u003e\u003cbr\u003eThis specific \u003cstrong\u003eDIN connector\u003c\/strong\u003e is engineered for the \u003cstrong\u003eASC2x type coil\u003c\/strong\u003e. Always verify the part number \u003cstrong\u003eX-28616\u003c\/strong\u003e against your existing coil’s nameplate to ensure correct fitment and pin configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the symptoms of a failing solenoid cable assembly?\u003c\/strong\u003e\u003cbr\u003eCommon indicators include intermittent valve operation, visible corrosion on the \u003cstrong\u003eDIN plug\u003c\/strong\u003e terminals, or \"chattering\" sounds from the solenoid suggesting inconsistent power delivery. Replacing the \u003cstrong\u003ecable assembly\u003c\/strong\u003e is a standard best practice when these issues arise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure a moisture-resistant seal during installation?\u003c\/strong\u003e\u003cbr\u003eEnsure the \u003cstrong\u003eDIN connector\u003c\/strong\u003e is fully seated and the center retaining screw is tightened to the recommended torque. Using a proper gasket (if applicable) prevents moisture ingress, which is a primary cause of short circuits in \u003cstrong\u003eHVACR refrigeration systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (Alco)","offers":[{"title":"Default Title","offer_id":35643953676,"sku":"059261","price":26.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Image_d557c7f2-2ab9-43fc-9764-defc455ff41c.png?v=1784236982"},{"product_id":"copeland-comfort-control-white-rodgers-pad-a04-1725-052-humidifier-p","title":"Copeland Comfort Control (White Rodgers) PAD-A04-1725-052 Humidifier Pad","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control PAD-A04-1725-052 Humidifier Pad\u003c\/strong\u003e is the direct OEM replacement for \u003cstrong\u003eWhite-Rodgers HFT2100\u003c\/strong\u003e high-capacity flow-thru humidifiers. Engineered for maximum evaporative efficiency, this \u003cstrong\u003ereplacement humidifier filter\u003c\/strong\u003e features a high-density porous structure that facilitates uniform water distribution across the media. As a veteran tech, you know that maintaining the \u003cstrong\u003eHFT2100 humidifier pad\u003c\/strong\u003e is critical for preventing mineral scale buildup that can lead to solenoid valve failure or drain line blockages. This pad is specifically designed to handle the 14-gallon per day output capacity of the \u003cstrong\u003eHFT2100 series\u003c\/strong\u003e, ensuring the system maintains consistent setpoints during peak heating season. Whether you are servicing a residential bypass setup or a light commercial application, using genuine \u003cstrong\u003eCopeland HVAC parts\u003c\/strong\u003e ensures the bypass damper and internal components are protected from bypass air leakage and moisture carryover.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Precision-fit for \u003cstrong\u003eWhite-Rodgers HFT2100\u003c\/strong\u003e and compatible flow-thru models to ensure zero-gap filtration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Evaporation Rates:\u003c\/strong\u003e Optimized surface area maximizes moisture transfer to the airstream for improved humidity control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMineral Retention:\u003c\/strong\u003e Advanced coating helps trap dissolved solids, reducing the frequency of system cleaning and protecting downstream ductwork.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructural Integrity:\u003c\/strong\u003e Rigid frame design prevents sag and bypass air, maintaining \u003cstrong\u003eHVAC system efficiency\u003c\/strong\u003e throughout the season.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the PAD-A04-1725-052 be replaced?\u003c\/strong\u003e For optimal \u003cstrong\u003eindoor air quality\u003c\/strong\u003e and equipment performance, we recommend replacing the pad at the start of every heating season. In areas with high mineral content in the water supply, a mid-season change may be necessary to prevent airflow restriction.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this pad fit other White-Rodgers models?\u003c\/strong\u003e This specific \u003cstrong\u003ehumidifier water panel\u003c\/strong\u003e is engineered for the \u003cstrong\u003eHFT2100\u003c\/strong\u003e high-capacity series. Always verify the dimensions and manufacturer part number against the existing housing to ensure a pressurized seal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this pad include the plastic distribution tray?\u003c\/strong\u003e No, the \u003cstrong\u003ePAD-A04-1725-052\u003c\/strong\u003e is the replacement evaporative media only. You should inspect the existing distribution tray for cracks or scale during installation and clean it thoroughly before inserting the new pad.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35643954316,"sku":"PAD-A04-1725-052","price":27.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_0bf58d10-6e80-4ec6-83d4-21d5ba43c5f7.png?v=1756165179"},{"product_id":"copeland-020-0941-00-o-ring-seal","title":"Copeland 020-0941-00 O-Ring Seal","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland 020-0941-00\u003c\/strong\u003e is a specialized \u003cstrong\u003esuction Rotalock O-ring seal\u003c\/strong\u003e designed specifically for the rigorous demands of \u003cstrong\u003eCopeland scroll compressors\u003c\/strong\u003e. Engineered for high-pressure refrigeration environments, this \u003cstrong\u003e2-1\/4\"-12 thread size gasket\u003c\/strong\u003e provides a critical seal between the suction service valve and the compressor housing. Utilizing \u003cstrong\u003enon-stick Teflon material\u003c\/strong\u003e, this seal prevents refrigerant migration and atmospheric contamination while resisting the thermal cycling common in \u003cstrong\u003eHVAC\/R commercial systems\u003c\/strong\u003e. Technicians specify this \u003cstrong\u003eRotalock valve gasket\u003c\/strong\u003e for its dimensional stability and chemical resistance to common POE oils and HFC\/HFO refrigerants. Maintaining a gas-tight suction connection is essential for system efficiency and preventing moisture ingress, making the \u003cstrong\u003e020-0941-00\u003c\/strong\u003e a necessary component for any professional compressor replacement or service overhaul.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Benefits for Contractors\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Sealing:\u003c\/strong\u003e High-grade Teflon construction ensures a \u003cstrong\u003eleak-proof suction connection\u003c\/strong\u003e under high-torque specifications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecision Compatibility:\u003c\/strong\u003e Designed specifically for \u003cstrong\u003e2-1\/4\"-12 Rotalock fittings\u003c\/strong\u003e found on large-tonnage scroll units.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e Maintains mechanical integrity across the wide temperature swings typical of \u003cstrong\u003esuction line applications\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAnti-Stick Properties:\u003c\/strong\u003e Simplifies future maintenance by preventing the gasket from bonding to the valve face or housing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Reliability:\u003c\/strong\u003e Direct \u003cstrong\u003eCopeland replacement part\u003c\/strong\u003e ensures exact tolerances and material compliance with refrigeration standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the thread size for the Copeland 020-0941-00?\u003c\/strong\u003e\u003cbr\u003e\nThis seal is designed for \u003cstrong\u003e2\/1-4\"-12 thread Rotalock connections\u003c\/strong\u003e, which are typically found on the suction side of larger scroll compressors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this seal be used with both R-22 and R-410A systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003eTeflon non-stick material\u003c\/strong\u003e is chemically compatible with standard HFCs and HCFCs, as well as mineral and POE lubricants used in \u003cstrong\u003erefrigeration and air conditioning\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this a standard O-ring or a flat gasket?\u003c\/strong\u003e\u003cbr\u003e\nThis is an \u003cstrong\u003eO-ring style Rotalock seal\u003c\/strong\u003e, specifically molded to seat within the groove of the Rotalock valve assembly for a \u003cstrong\u003ecompression-tight fit\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland","offers":[{"title":"Default Title","offer_id":35643988876,"sku":"020-0941-00","price":21.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_c7bbbd4a-60ac-4408-9e5d-00c84890ab88.png?v=1756165178"},{"product_id":"copeland-comfort-control-alco-047603-filter-drier","title":"Copeland Comfort Control (Alco) 047603 Filter Drier","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (Alco) 047603 Filter Drier\u003c\/strong\u003e is a critical liquid line component engineered for high-moisture and contaminant removal in residential and commercial refrigeration systems. As a direct \u003cstrong\u003eOEM replacement for 029-21710-000\u003c\/strong\u003e and the \u003cstrong\u003eAlco EK-053\u003c\/strong\u003e, this unit features a \u003cstrong\u003e5 cubic inch\u003c\/strong\u003e desiccant bead volume optimized for \u003cstrong\u003eCFC, HCFC, and HFC refrigerants\u003c\/strong\u003e, including R-410A. The \u003cstrong\u003e3\/8\" flare connection\u003c\/strong\u003e ensures a mechanical, leak-resistant seal without the need for brazing, making it ideal for field repairs and routine maintenance. Rated for a \u003cstrong\u003e680 PSI maximum working pressure\u003c\/strong\u003e, this filter drier utilizes a \u003cstrong\u003e20-micron filtration\u003c\/strong\u003e pad to capture solid particulates like copper filings and carbon, preventing expansion valve orifice plugging and preventing acid formation. By maintaining a clean \u003cstrong\u003erefrigerant liquid line\u003c\/strong\u003e, this \u003cstrong\u003eEK series filter drier\u003c\/strong\u003e protects compressor integrity and ensures stable subcooling across the metering device.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Benefits for Contractors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Refrigerant Compatibility:\u003c\/strong\u003e Designed to handle high-pressure synthetic oils (POE) and traditional mineral oils without compromising desiccant integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Filtration:\u003c\/strong\u003e The \u003cstrong\u003e20-micron rating\u003c\/strong\u003e effectively traps system debris that can cause mechanical failure in reciprocating or scroll compressors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Moisture Absorption:\u003c\/strong\u003e Large internal surface area provides maximum water capacity, preventing ice formation at the expansion valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect OEM Specification:\u003c\/strong\u003e Ensures exact fitment and flow characteristics for \u003cstrong\u003eYork 029-21710-000\u003c\/strong\u003e and primary Alco system configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Shock-resistant steel shell capable of withstanding high-vibration environments in heavy-duty HVAC\/R applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Copeland 047603 compatible with R-410A systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, with a maximum pressure rating of \u003cstrong\u003e680 PSI\u003c\/strong\u003e, this \u003cstrong\u003eliquid line filter drier\u003c\/strong\u003e is fully compatible with high-pressure R-410A systems as well as R-22 and R-134a applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the Alco EK-053 and the Copeland 047603?\u003c\/strong\u003e\u003cbr\u003e\nThey are functionally identical. The \u003cstrong\u003e047603\u003c\/strong\u003e is the specific part number used for wholesale and OEM distribution, while \u003cstrong\u003eEK-053\u003c\/strong\u003e refers to the Alco model prefix for a 5 cubic inch drier with 3\/8\" flare fittings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this filter drier be installed in either direction?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is a \u003cstrong\u003estandard liquid line drier\u003c\/strong\u003e and is unidirectional. Technicians must follow the flow arrow stamped on the shell to ensure proper filtration and prevent internal bypass.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (Alco)","offers":[{"title":"Default Title","offer_id":35644001804,"sku":"47603","price":15.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_3f2786cb-dd54-4eb2-9b92-715aabd49a76.png?v=1755193408"},{"product_id":"copeland-comfort-control-white-rodgers-24a34-2-heat-sequencer","title":"Copeland Comfort Control (White Rodgers) 24A34-2 Heat Sequencer","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control 24A34-2 Heat Sequencer\u003c\/strong\u003e is a heavy-duty \u003cstrong\u003esingle-switch electric heat relay\u003c\/strong\u003e engineered for precise staging in residential and commercial forced-air systems. As a veteran-grade \u003cstrong\u003eHVAC sequencer replacement\u003c\/strong\u003e, this unit provides the essential \u003cstrong\u003etime delay control\u003c\/strong\u003e required to prevent excessive current draw by staggering the activation of heating elements and blower motors. Specifically designed as a \u003cstrong\u003e24V heat sequencer\u003c\/strong\u003e, the 24A34-2 features an \"on\" timing range of 30 to 90 seconds and an \"off\" timing of 1 to 30 seconds, ensuring smooth operation of the \u003cstrong\u003eelectric furnace sequencer\u003c\/strong\u003e circuit. This \u003cstrong\u003eWhite Rodgers 24A34-2\u003c\/strong\u003e model is the \u003cstrong\u003edirect replacement for F77-5410\u003c\/strong\u003e and is compatible with various \u003cstrong\u003eauxiliary contacts\u003c\/strong\u003e. Its \u003cstrong\u003emulti-poise mounting\u003c\/strong\u003e capability allows for flexible installation in tight cabinets, while the \u003cstrong\u003edouble quick-connect terminals\u003c\/strong\u003e simplify wiring for 120, 240, or 480 VAC combination loads. Built to handle 25A resistive loads at 3000W, this \u003cstrong\u003esequencing relay\u003c\/strong\u003e is a reliable solution for technicians troubleshooting \u003cstrong\u003efurnace fan limit switches\u003c\/strong\u003e or \u003cstrong\u003estaged heating controls\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for the Job Site:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Verified 1-to-1 swap for the \u003cstrong\u003eWhite Rodgers F77-5410\u003c\/strong\u003e, reducing diagnostic and downtime.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Terminal Markings:\u003c\/strong\u003e Standardized coding matches most competitive brands like Honeywell, Mars, and Klixon for faster \u003cstrong\u003efield wiring\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStaged Performance:\u003c\/strong\u003e Thermal-expansion design prevents \u003cstrong\u003ecircuit breaker tripping\u003c\/strong\u003e by ensuring elements do not energize simultaneously.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Load Rating:\u003c\/strong\u003e rated for 14A inductive and 25A resistive at 240V, making it suitable for high-demand \u003cstrong\u003eelectric heat elements\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e The multi-poise base plate allows for vertical or horizontal orientation without affecting \u003cstrong\u003ethermal timing\u003c\/strong\u003e accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Technician Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this to replace a sequencer with more than one switch?\u003c\/strong\u003e\u003cbr\u003e\nNo. The 24A34-2 is a \u003cstrong\u003e1-switch sequencer\u003c\/strong\u003e. If your unit requires multiple stages (e.g., M1-M2 and M3-M4), you must use the appropriate multi-switch model to maintain proper \u003cstrong\u003eheat staging\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the timing adjustable on this unit?\u003c\/strong\u003e\u003cbr\u003e\nThe timings (30-90s on, 1-30s off) are factory-set by the internal thermal \u003cstrong\u003ebimetal switch\u003c\/strong\u003e and are not field-adjustable. These ranges are designed to meet standard \u003cstrong\u003eHVAC equipment\u003c\/strong\u003e safety specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes a heat sequencer to fail prematurely?\u003c\/strong\u003e\u003cbr\u003e\nCommon failure points include \u003cstrong\u003earcing contacts\u003c\/strong\u003e from loose terminal connections or a weakened internal heater coil. If the \u003cstrong\u003eblower motor\u003c\/strong\u003e stays on or elements won’t engage, check the 24V signal to the H1-H2 terminals first.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644003724,"sku":"24A34-2","price":14.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_259a18a4-790d-4eb9-8374-6a2fb957bcfd.png?v=1756165177"},{"product_id":"copeland-comfort-control-white-rodgers-f92-1011-conversion-kit","title":"Copeland Comfort Control (White Rodgers) F92-1011 Conversion Kit","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) F92-1011 Conversion Kit\u003c\/strong\u003e is a field-proven solution for technicians tasked with transitioning high-efficiency systems from \u003cstrong\u003eliquid propane (LP) to natural gas\u003c\/strong\u003e. This OEM-certified kit is specifically engineered for the \u003cstrong\u003eWhite Rodgers 36G and 36J series two-stage gas valves\u003c\/strong\u003e, common in modern \u003cstrong\u003efurnace repair\u003c\/strong\u003e and \u003cstrong\u003eHVAC service\u003c\/strong\u003e. By replacing the existing LP regulator springs with the silver-coded natural gas springs included in this \u003cstrong\u003enatural gas conversion kit\u003c\/strong\u003e, you ensure the valve maintains the precise manifold pressure required for safe, high-performance combustion. This \u003cstrong\u003egas valve conversion\u003c\/strong\u003e is essential for maintaining the factory-specified firing rates of \u003cstrong\u003etwo-stage gas valves\u003c\/strong\u003e, protecting the heat exchanger from improper thermal stress. Designed for durability and \u003cstrong\u003eOEM quality\u003c\/strong\u003e, the \u003cstrong\u003eWhite Rodgers F92-1011\u003c\/strong\u003e meets strict safety standards, ensuring that \u003cstrong\u003eheating and cooling services\u003c\/strong\u003e can be completed with confidence and long-term reliability in the field.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for the Contractor:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Compatibility:\u003c\/strong\u003e Engineered specifically for \u003cstrong\u003eWhite Rodgers 36G and 36J gas valves\u003c\/strong\u003e, ensuring a perfect mechanical fit without modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Pressure Regulation:\u003c\/strong\u003e Includes high and low stage springs to accurately regulate \u003cstrong\u003enatural gas\u003c\/strong\u003e flow for \u003cstrong\u003etwo-stage heating systems\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Components:\u003c\/strong\u003e Package contains the necessary \u003cstrong\u003eregulator springs\u003c\/strong\u003e, cover screws, and \u003cstrong\u003eNAT GAS stickers\u003c\/strong\u003e for proper identification post-conversion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional Reliability:\u003c\/strong\u003e An \u003cstrong\u003eOEM-approved conversion kit\u003c\/strong\u003e is the only way to ensure the gas valve operates within its original safety parameters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Helps technicians follow \u003cstrong\u003eNational Fuel Gas Code\u003c\/strong\u003e requirements when performing \u003cstrong\u003eLP to natural gas transitions\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhich gas valves is the F92-1011 compatible with?\u003c\/strong\u003e\u003cbr\u003e\nThis kit is designed for \u003cstrong\u003eWhite Rodgers 36G and 36J series two-stage gas valves\u003c\/strong\u003e, including fast and slow-opening models. Always verify the valve series on the nameplate before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this kit include orifices for the burners?\u003c\/strong\u003e\u003cbr\u003e\nNo, the \u003cstrong\u003eF92-1011\u003c\/strong\u003e is a \u003cstrong\u003eregulated conversion kit\u003c\/strong\u003e that focuses on the gas valve components (springs and labels). Burner orifices must be sourced separately based on the appliance manufacturer's BTU specifications and local altitude.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is a special kit needed for two-stage valves?\u003c\/strong\u003e\u003cbr\u003e\nTwo-stage valves require two separate spring adjustments to manage high and low fire cycles. This kit provides the specific tension needed to calibrate both stages correctly for \u003cstrong\u003enatural gas\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCalifornia Proposition 65 Warning:\u003c\/strong\u003e\u003cbr\u003e\nThis product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644088140,"sku":"F92-1011","price":18.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_c192cc90-ded4-42d3-8b17-6ba7a2c1d5b2.png?v=1683827095"},{"product_id":"copeland-comfort-control-white-rodgers-pad-a04-1725-051-humidifier-p","title":"Copeland Comfort Control (White Rodgers) PAD-A04-1725-051 Humidifier Pad","description":"\u003cp\u003e\u003cspan\u003eHUMIDIFIER PAD, HFTs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePAD-A04-1725-051 is identical to A04-1725-051\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"0\" data-end=\"78\"\u003e\u003cstrong data-start=\"0\" data-end=\"76\"\u003eCopeland Comfort Control (White Rodgers) PAD-A04-1725-051 Humidifier Pad\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"80\" data-end=\"469\"\u003e\u003cstrong data-start=\"80\" data-end=\"93\"\u003eOverview:\u003c\/strong\u003e\u003cbr data-start=\"93\" data-end=\"96\"\u003eThe \u003cstrong data-start=\"100\" data-end=\"176\"\u003eCopeland Comfort Control (White Rodgers) PAD-A04-1725-051 Humidifier Pad\u003c\/strong\u003e is a genuine OEM replacement part designed to maintain optimal humidity levels in your home or commercial HVAC system. Engineered for high efficiency and reliability, this humidifier pad ensures consistent moisture output and helps improve indoor air quality by reducing dryness and static.\u003c\/p\u003e\n\u003cp data-start=\"471\" data-end=\"490\"\u003e\u003cstrong data-start=\"471\" data-end=\"488\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"491\" data-end=\"1033\"\u003e\n\u003cli data-start=\"491\" data-end=\"616\"\u003e\n\u003cp data-start=\"493\" data-end=\"616\"\u003e\u003cstrong data-start=\"493\" data-end=\"509\"\u003eOEM Quality:\u003c\/strong\u003e Genuine \u003cstrong data-start=\"518\" data-end=\"552\"\u003eWhite Rodgers PAD-A04-1725-051\u003c\/strong\u003e humidifier pad ensures perfect compatibility and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"617\" data-end=\"717\"\u003e\n\u003cp data-start=\"619\" data-end=\"717\"\u003e\u003cstrong data-start=\"619\" data-end=\"648\"\u003eOptimal Humidity Control:\u003c\/strong\u003e Maintains ideal moisture levels for comfort and system efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"718\" data-end=\"836\"\u003e\n\u003cp data-start=\"720\" data-end=\"836\"\u003e\u003cstrong data-start=\"720\" data-end=\"739\"\u003eDurable Design:\u003c\/strong\u003e Made from high-quality materials for long-lasting reliability and consistent water absorption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"837\" data-end=\"932\"\u003e\n\u003cp data-start=\"839\" data-end=\"932\"\u003e\u003cstrong data-start=\"839\" data-end=\"861\"\u003eEasy Installation:\u003c\/strong\u003e Designed for quick replacement to keep your system running smoothly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"933\" data-end=\"1033\"\u003e\n\u003cp data-start=\"935\" data-end=\"1033\"\u003e\u003cstrong data-start=\"935\" data-end=\"960\"\u003eImproved Air Quality:\u003c\/strong\u003e Helps reduce static electricity, dry skin, and respiratory irritation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1035\" data-end=\"1056\"\u003e\u003cstrong data-start=\"1035\" data-end=\"1054\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1057\" data-end=\"1286\"\u003e\n\u003cli data-start=\"1057\" data-end=\"1094\"\u003e\n\u003cp data-start=\"1059\" data-end=\"1094\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1075\"\u003ePart Number:\u003c\/strong\u003e PAD-A04-1725-051\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1095\" data-end=\"1150\"\u003e\n\u003cp data-start=\"1097\" data-end=\"1150\"\u003e\u003cstrong data-start=\"1097\" data-end=\"1107\"\u003eBrand:\u003c\/strong\u003e Copeland Comfort Control (White Rodgers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1151\" data-end=\"1179\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1179\"\u003e\u003cstrong data-start=\"1153\" data-end=\"1162\"\u003eType:\u003c\/strong\u003e Humidifier Pad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1180\" data-end=\"1220\"\u003e\n\u003cp data-start=\"1182\" data-end=\"1220\"\u003e\u003cstrong data-start=\"1182\" data-end=\"1195\"\u003eCategory:\u003c\/strong\u003e HVAC Replacement Parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1221\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1223\" data-end=\"1286\"\u003e\u003cstrong data-start=\"1223\" data-end=\"1241\"\u003eCompatibility:\u003c\/strong\u003e Fits HFTs and compatible humidifier models\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1288\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1325\"\u003eWhy Choose OEM Replacement Parts?\u003c\/strong\u003e\u003cbr data-start=\"1325\" data-end=\"1328\"\u003eUsing genuine OEM components like the \u003cstrong data-start=\"1366\" data-end=\"1427\"\u003eCopeland Comfort Control (White Rodgers) PAD-A04-1725-051\u003c\/strong\u003e ensures proper fit, peak performance, and extended system life. Avoid costly downtime and maintain factory-level efficiency by replacing your humidifier pad regularly.\u003c\/p\u003e\n\u003cp data-start=\"1599\" data-end=\"1808\"\u003e\u003cstrong data-start=\"1599\" data-end=\"1624\"\u003eShop with Confidence:\u003c\/strong\u003e\u003cbr data-start=\"1624\" data-end=\"1627\"\u003eGet the \u003cstrong data-start=\"1635\" data-end=\"1684\"\u003eWhite Rodgers PAD-A04-1725-051 Humidifier Pad\u003c\/strong\u003e today ?Çö in stock and ready to ship. Perfect replacement for maintaining comfort and air quality in your home or business.\u003c\/p\u003e\n\u003cp data-start=\"1810\" data-end=\"2032\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"1810\" data-end=\"1823\"\u003eKeywords:\u003c\/strong\u003e\u003cbr data-start=\"1823\" data-end=\"1826\"\u003eWhite Rodgers PAD-A04-1725-051, Copeland Comfort Control Humidifier Pad, HFTs Humidifier Filter, OEM Replacement Pad, HVAC Humidifier Pad, PAD-A04-1725-051 Replacement Filter, White Rodgers Humidifier Parts\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: red;\"\u003eThis item is not?áeligible?áfor free shipping.\u003c\/span\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; color: red; background: white;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644092684,"sku":"PAD-A04-1725-051","price":11800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_31f5dee6-c01a-40a7-9141-6583e9d13faa.png?v=1760738378"},{"product_id":"copeland-comfort-control-white-rodgers-3l09-12-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L09-12 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White-Rodgers) 3L09-12 Limit Switch\u003c\/strong\u003e is a high-reliability \u003cstrong\u003e1\/2\" bimetal disc limit control\u003c\/strong\u003e engineered for precision high-limit protection in residential and commercial furnaces. This \u003cstrong\u003eboard-mounted HVAC limit switch\u003c\/strong\u003e features a fixed open temperature of \u003cstrong\u003e220°F\u003c\/strong\u003e and a fixed close temperature of \u003cstrong\u003e180°F\u003c\/strong\u003e. Operating on an \u003cstrong\u003eopen-on-rise switch action\u003c\/strong\u003e, it serves as a critical safety component to prevent heat exchanger damage or hazardous overheating conditions. As a direct \u003cstrong\u003e626435R cross reference\u003c\/strong\u003e, this \u003cstrong\u003eType 36T (Style 612722)\u003c\/strong\u003e thermal disc ensures seamless integration into existing control boards. The \u003cstrong\u003e3.12\" insertion length\u003c\/strong\u003e allows for accurate sensing within the plenum air stream, while the \u003cstrong\u003eauto reset\u003c\/strong\u003e functionality allows the system to resume normal operation once the temperature drops below the 180°F threshold.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits for Professionals\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Compatibility:\u003c\/strong\u003e Authentic White-Rodgers\/Copeland component designed as a drop-in replacement for \u003cstrong\u003eTherm-O-Disc Style 612722\u003c\/strong\u003e applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Calibration:\u003c\/strong\u003e Fixed \u003cstrong\u003e220 degree F cut-out\u003c\/strong\u003e ensures the system stays within safe operating parameters without the drift common in lower-quality aftermarket switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Board Mount Design:\u003c\/strong\u003e Features a \u003cstrong\u003eboard-mounted 1\/2\" bimetal disc\u003c\/strong\u003e for stable installation and consistent vibration resistance in high-airflow environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Built to handle the thermal cycling demands of modern high-efficiency furnaces and HVAC equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Installation:\u003c\/strong\u003e The standard \u003cstrong\u003e3L09-12\u003c\/strong\u003e footprint and 3.12-inch probe length facilitate fast field replacements to minimize equipment downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3L09-12 an automatic or manual reset switch?\u003c\/strong\u003e\u003cbr\u003e\nThis is an \u003cstrong\u003eauto reset limit switch\u003c\/strong\u003e. It will automatically re-close the circuit once the sensed temperature falls to 180°F, eliminating the need for a manual technician reset after a high-temperature event.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does 'Open on Rise' mean for this furnace limit?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eOpen on Rise\u003c\/strong\u003e means the electrical contacts break (opening the circuit) when the temperature climbs to the 220°F setpoint, typically shutting down the gas valve or heating element to protect the system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use this as a replacement for the 626435R?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e3L09-12\u003c\/strong\u003e is the designated technical cross-reference for part number \u003cstrong\u003e626435R\u003c\/strong\u003e, matching its physical dimensions and thermal specifications.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644108876,"sku":"3L09-12","price":18.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_3da64493-1c13-405f-945b-4f876b9bfbab.png?v=1772595595"},{"product_id":"copeland-comfort-control-white-rodgers-3l09-17-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L09-17 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 3L09-17\u003c\/strong\u003e is a board-mounted \u003cstrong\u003e1\/2\" bimetal disc limit switch\u003c\/strong\u003e engineered for precision thermal protection in HVAC systems. Designed with an \u003cstrong\u003eopen on rise switch action\u003c\/strong\u003e, this \u003cstrong\u003efixed-setting temperature control\u003c\/strong\u003e features a 250°F fixed open temperature and a 225°F fixed close temperature, providing a 25°F differential crucial for preventing high-limit excursions and equipment cycling issues. This \u003cstrong\u003eauto reset limit switch\u003c\/strong\u003e utilizes a 3.12\" insertion length, making it a critical \u003cstrong\u003eOEM replacement part\u003c\/strong\u003e for specific furnace and air handler configurations. It serves as the \u003cstrong\u003edirect replacement for SHL518\u003c\/strong\u003e, ensuring seamless integration during \u003cstrong\u003efurnace limit switch replacement\u003c\/strong\u003e. For service technicians, the robust construction provides reliable \u003cstrong\u003eHVAC high limit control\u003c\/strong\u003e, ensuring circuit interruption when setpoints are exceeded. Its board-mounted design simplifies installation in tight control compartments while maintaining the specified \u003cstrong\u003ethermal cutout\u003c\/strong\u003e accuracy required for safe combustion cycles and system longevity.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Technical Benefits\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecise Thermal Calibration:\u003c\/strong\u003e Fixed 250°F trip point ensures reliable over-temperature protection.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAutomatic Reset Functionality:\u003c\/strong\u003e Switches back at 225°F, reducing unnecessary service calls for manual resets.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Compatibility:\u003c\/strong\u003e Engineered as the exact \u003cstrong\u003eSHL518 replacement\u003c\/strong\u003e for simplified cross-referencing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Insertion Length:\u003c\/strong\u003e 3.12\" probe reaches deep into the heat exchanger airflow for accurate sensing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBimetal Reliability:\u003c\/strong\u003e 1\/2\" disc technology offers consistent performance under high-cycle industrial conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes a limit switch like the 3L09-17 to trip frequently?\u003c\/strong\u003e\u003cbr\u003e\nRepeated tripping usually indicates restricted airflow, often due to a clogged filter, undersized ductwork, or a failing blower motor, causing the heat exchanger to exceed the 250°F threshold.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I use a different insertion length if the 3.12\" probe is unavailable?\u003c\/strong\u003e\u003cbr\u003e\nNo. The insertion length is specific to the heat exchanger geometry. Using a shorter or longer probe will result in inaccurate temperature sensing and potential safety hazards.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I verify if the 3L09-17 is the correct part for my system?\u003c\/strong\u003e\u003cbr\u003e\nConfirm the fixed open\/close temperatures and the insertion length match your existing OEM specifications or technical manual before installation.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644109644,"sku":"3L09-17","price":18.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_10e0fe00-b992-409d-a9ab-78e2f38ad17b.png?v=1756165177"},{"product_id":"copeland-comfort-control-white-rodgers-3l09-27-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L09-27 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 3L09-27 Limit Switch\u003c\/strong\u003e is a critical safety component engineered for precise thermal management in high-demand HVAC and refrigeration systems. This \u003cstrong\u003eboard-mounted 1\/2\" bimetal disc limit switch\u003c\/strong\u003e features a \u003cstrong\u003efixed open temperature of 220°F\u003c\/strong\u003e and a \u003cstrong\u003efixed close temperature of 200°F\u003c\/strong\u003e, providing a consistent 20°F differential for equipment protection. Designed with \u003cstrong\u003eopen on rise switch action\u003c\/strong\u003e, the 3L09-27 ensures immediate circuit interruption during over-temperature conditions, while the \u003cstrong\u003eauto reset\u003c\/strong\u003e functionality allows the system to resume operation once the temperature drops below the set point. With a \u003cstrong\u003e1.87\" insertion length\u003c\/strong\u003e, this compact switch is a direct \u003cstrong\u003e3L09-27 cross for S1-026-32588-005\u003c\/strong\u003e, making it a versatile replacement part for furnace high-limit applications and industrial temperature monitoring where board-level mounting is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Serves as a direct replacement for \u003cstrong\u003eS1-026-32588-005\u003c\/strong\u003e and many \u003cstrong\u003eWhite Rodgers 3L09 series\u003c\/strong\u003e applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Limit Protection:\u003c\/strong\u003e Precisely calibrated \u003cstrong\u003e220 degree F open temperature\u003c\/strong\u003e prevents heat exchanger damage and unsafe operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Resets:\u003c\/strong\u003e The \u003cstrong\u003eautomatic reset\u003c\/strong\u003e feature eliminates unnecessary service calls for manual intervention after temporary thermal spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Installation:\u003c\/strong\u003e Designed for \u003cstrong\u003eboard-mounted\u003c\/strong\u003e configurations with a standard 1.87-inch depth for quick field replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Grade Durability:\u003c\/strong\u003e Built with a \u003cstrong\u003e1\/2 inch bimetal disc\u003c\/strong\u003e to withstand high-cycling environments in both residential and commercial units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Technical Insights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and a manual reset switch?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003e3L09-27\u003c\/strong\u003e is an \u003cstrong\u003eauto reset limit switch\u003c\/strong\u003e, meaning it will automatically close the circuit once the temperature cools to 200°F. Manual reset switches require a physical button press, typically required by local codes for rollout switches rather than primary limits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this be used in place of a different insertion length?\u003c\/strong\u003e\u003cbr\u003e\nIt is critical to maintain the \u003cstrong\u003e1.87\" insertion length\u003c\/strong\u003e to ensure the bimetal disc sits in the correct airflow path. Using a shorter or longer probe may result in inaccurate temperature sensing and premature tripping.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat causes a 220 degree F limit switch to trip?\u003c\/strong\u003e\u003cbr\u003e\nFrequent tripping of a \u003cstrong\u003ehigh limit switch\u003c\/strong\u003e usually indicates restricted airflow, such as a clogged filter, a failing blower motor, or an oversized furnace for the existing ductwork.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644110860,"sku":"3L09-27","price":18.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_1264e276-e4c9-4650-b298-3cc4c64d6135.png?v=1764104045"},{"product_id":"copeland-comfort-control-white-rodgers-24a34-3-heat-sequencer","title":"Copeland Comfort Control (White Rodgers) 24A34-3 Heat Sequencer","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 24A34-3 Heat Sequencer\u003c\/strong\u003e is a professional-grade \u003cstrong\u003e2-switch electric heat sequencer\u003c\/strong\u003e engineered for precise timing in electric furnaces and heat pump systems. Designed as a \u003cstrong\u003edirect replacement for F77-5411\u003c\/strong\u003e, this unit manages 24V input control to activate heating elements and blower motors in a staggered sequence, preventing excessive inrush current. It features \u003cstrong\u003e1-20 second On timings\u003c\/strong\u003e and \u003cstrong\u003e40-110 second Off timings\u003c\/strong\u003e, ensuring the system maintains airflow until the heat exchangers have sufficiently cooled. For contractors, the \u003cstrong\u003emulti-poise mounting\u003c\/strong\u003e and standard terminal markings allow for a seamless \u003cstrong\u003eHVAC sequencer installation\u003c\/strong\u003e across various manufacturer platforms, including \u003cstrong\u003edirect replacement for Honeywell, Mars, and TOD\u003c\/strong\u003e controls. This \u003cstrong\u003eDPST electric heat sequencer\u003c\/strong\u003e supports combination loads with double quick-connect terminals, facilitating a reliable \u003cstrong\u003e24V furnace sequencer\u003c\/strong\u003e repair that restores proper fan-to-element synchronization in multi-stage electric heat applications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Serves as a universal \u003cstrong\u003eelectric furnace sequencer replacement\u003c\/strong\u003e for major brands like Honeywell, Klixon, and Gemline.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Fan Interlock:\u003c\/strong\u003e The M1-M2 contacts ensure the blower initiates first and terminates last for safe heat dissipation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Load Capacity:\u003c\/strong\u003e Rated for 25.0A resistive and 14.0 FLA \/ 72.0 LRA at 120VAC, accommodating heavy heating element demands.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Maintains operational integrity within a wide ambient temperature range of -50°F to 165°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a heat sequencer do in an electric furnace?\u003c\/strong\u003e\u003cbr\u003e\nIt provides a time-delayed sequence for energized heating elements to prevent electrical overloads and ensures the blower motor continues running until the residual heat is cleared from the plenum.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the 24A34-3 replace a sequencer with more switches?\u003c\/strong\u003e\u003cbr\u003e\nThis model is a \u003cstrong\u003e2-switch sequencer\u003c\/strong\u003e. While multiple units can sometimes be wired in series for staging, it is best practice to match the switch count of the original OEM part unless the circuit is specifically redesigned by a qualified HVAC technician.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the 24A34-3 compatible with 240V systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, while the control heater uses 24V, the contacts are rated for 120V, 240V, and 480V loads, making it standard for residential 240V electric furnaces.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644145804,"sku":"24A34-3","price":16.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_4c014e61-4f5f-4cb0-8deb-e8e654e19a80.jpg?v=1756165176"},{"product_id":"copeland-comfort-control-white-rodgers-1c20-102-vert-stat","title":"Copeland Comfort Control (White Rodgers) 1C20-102 Vert-Stat","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 1C20-102\u003c\/strong\u003e is a field-proven \u003cstrong\u003e24V single-stage heating thermostat\u003c\/strong\u003e designed for straightforward mechanical reliability in residential and light commercial service. This \u003cstrong\u003enon-programmable vertical thermostat\u003c\/strong\u003e features a bimetal sensing element and \u003cstrong\u003erugged snap-action contacts\u003c\/strong\u003e, making it an ideal choice for \u003cstrong\u003egas, oil, and electric heating systems\u003c\/strong\u003e that do not require fan control from the thermostat. With a \u003cstrong\u003emercury-free design\u003c\/strong\u003e and an adjustable \u003cstrong\u003eheat anticipator\u003c\/strong\u003e (0.15 to 1.2 Amps), it allows technicians to fine-tune cycle rates to match the specific current draw of the primary heating control, ensuring consistent setpoint stability and reducing system short-cycling.\u003c\/p\u003e\n\n\u003cp\u003eBuilt as a \u003cstrong\u003elow-voltage heating control\u003c\/strong\u003e, the 1C20-102 covers a temperature range of \u003cstrong\u003e50°F to 90°F\u003c\/strong\u003e. The unit includes a \u003cstrong\u003eswitching subbase\u003c\/strong\u003e and utilizes a simple \u003cstrong\u003etwo-wire (RH, W)\u003c\/strong\u003e terminal configuration, facilitating rapid \u003cstrong\u003ethermostat replacement\u003c\/strong\u003e on legacy vertical mounts. Its classic \u003cstrong\u003emechanical room thermostat\u003c\/strong\u003e interface is preferred by contractors who prioritize durability and ease of use in environments where digital complexity is unnecessary. For millivolt applications, the contact arm can be adjusted to the millivolt link setting, providing versatile compatibility across various \u003cstrong\u003e24VAC heating applications\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for HVAC Professionals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Application:\u003c\/strong\u003e Compatible with most 24V single-stage gas, oil, or electric furnaces and 2-wire hydronic systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Tuning:\u003c\/strong\u003e The \u003cstrong\u003eadjustable heat anticipator\u003c\/strong\u003e allows for custom cycle rate optimization based on system amperage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Reliability:\u003c\/strong\u003e \u003cstrong\u003eSnap-action contacts\u003c\/strong\u003e provide a positive electrical connection and long-term switching performance without the failure points of electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmentally Compliant:\u003c\/strong\u003e Fully \u003cstrong\u003emercury-free\u003c\/strong\u003e construction meets all modern environmental safety standards for disposal and installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContractor-Friendly Install:\u003c\/strong\u003e Features a vertical rounded profile and included mounting hardware for a clean, professional finish on standard electrical boxes or drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions \u0026amp; Technical Insights:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1C20-102 compatible with heat pumps?\u003c\/strong\u003e\u003cbr\u003e\nThis model is designed for \u003cstrong\u003eheat-only systems\u003c\/strong\u003e. For single-stage heat pump applications without auxiliary heat, a jumper across W and Y may be required, though a dedicated heat pump thermostat is generally recommended for full functionality.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I set the heat anticipator correctly?\u003c\/strong\u003e\u003cbr\u003e\nThe anticipator should be matched to the current rating stamped on the main furnace control or measured via a digital clamp meter on the white (W) wire during a call for heat. Rotating the contact arm lengthens or shortens the cycles to prevent overshooting the setpoint.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this thermostat require batteries?\u003c\/strong\u003e\u003cbr\u003e\nNo. As a \u003cstrong\u003emechanical thermostat\u003c\/strong\u003e, it operates via bimetal expansion and system power, eliminating nuisance calls caused by dead batteries.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644163660,"sku":"1C20-102","price":18.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_9a0755a1-1c09-443a-8ae2-1673c8ae066f.png?v=1684798434"},{"product_id":"copeland-comfort-control-white-rodgers-767a-370-ignitor","title":"Copeland Comfort Control (White Rodgers) 767A-370 Ignitor","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:3f664037-7ca8-4232-9a9f-e33cd1c1c32c-21\" data-testid=\"conversation-turn-44\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9568bb90-c4c6-4dd9-8792-d4071c3ee744\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"0\" data-end=\"706\"\u003eThe Copeland Comfort Control (White Rodgers) 767A-370 ignitor is a reliable furnace hot surface ignitor designed for consistent ignition performance in gas-fired HVAC systems. Featuring 5-1\/4 inch leads and an M-style mounting configuration, this ignitor is built for direct replacement in compatible residential and light commercial furnaces. It provides fast heat-up and stable operation, ensuring dependable burner ignition during system startup. This White Rodgers ignitor is commonly used by technicians when addressing ignition failures, cracked elements, or worn-out components. Designed to meet OEM specifications, it offers proper fit and electrical compatibility across a range of furnace models.\u003c\/p\u003e\n\u003cp data-start=\"708\" data-end=\"721\"\u003eKey Benefits:\u003c\/p\u003e\n\u003cul data-start=\"722\" data-end=\"970\"\u003e\n\u003cli data-section-id=\"1d6of8a\" data-start=\"722\" data-end=\"774\"\u003e5-1\/4 inch lead length for standard installation\u003c\/li\u003e\n\u003cli data-section-id=\"3uutqc\" data-start=\"775\" data-end=\"821\"\u003eM-style mounting for secure and proper fit\u003c\/li\u003e\n\u003cli data-section-id=\"2z7oji\" data-start=\"822\" data-end=\"867\"\u003eDesigned for gas furnace ignition systems\u003c\/li\u003e\n\u003cli data-section-id=\"r93oaf\" data-start=\"868\" data-end=\"917\"\u003eDirect OEM replacement for compatible systems\u003c\/li\u003e\n\u003cli data-section-id=\"1y5myy6\" data-start=\"918\" data-end=\"970\"\u003eSupports reliable and consistent burner ignition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"972\" data-end=\"989\"\u003eCommon Questions:\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1077\"\u003eWhat does this ignitor do?\u003cbr data-start=\"1017\" data-end=\"1020\"\u003eIt heats up to ignite the gas burner in a furnace system.\u003c\/p\u003e\n\u003cp data-start=\"1079\" data-end=\"1218\"\u003eIs this compatible with my furnace?\u003cbr data-start=\"1114\" data-end=\"1117\"\u003eCompatibility depends on the model and mounting style. Please verify the part number before ordering.\u003c\/p\u003e\n\u003cp data-start=\"1220\" data-end=\"1340\"\u003eWhat are signs of a failed ignitor?\u003cbr data-start=\"1255\" data-end=\"1258\"\u003eCommon signs include no ignition, visible cracks, or the furnace failing to start.\u003c\/p\u003e\n\u003cp data-start=\"1342\" data-end=\"1532\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644170828,"sku":"767A-370","price":20.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_37b4944a-a7e9-4c7e-ab32-e9ec472081b1.png?v=1775089413"},{"product_id":"copeland-comfort-control-white-rodgers-767a-372-ignitor","title":"Copeland Comfort Control (White Rodgers) 767A-372 Ignitor","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 767A-372 Ignitor\u003c\/strong\u003e is a high-performance \u003cstrong\u003esilicon carbide hot surface ignitor\u003c\/strong\u003e designed for high-volume OEM direct replacement applications. Engineered with an \u003cstrong\u003eN-style mounting block\u003c\/strong\u003e, this 2.0 lb component facilitates precise alignment within the burner assembly. It features \u003cstrong\u003e5 1\/4-inch leads\u003c\/strong\u003e insulated to withstand temperatures up to 200°C, terminating in a \u003cstrong\u003eMolex side lock connector\u003c\/strong\u003e with 0.092-inch male pins for secure electrical integration. This \u003cstrong\u003e120V HSI element\u003c\/strong\u003e is technically rated for 15, 17, or 45-second ignition systems, making it a versatile choice for \u003cstrong\u003efurnaces, boilers, and infrared heaters\u003c\/strong\u003e from brands like Rheem, Lennox, and Trane. For field technicians, the \u003cstrong\u003e767A-372\u003c\/strong\u003e ensures reliable gas ignition by reaching high-temperature incandescence rapidly. To maintain the integrity of the \u003cstrong\u003ecarbide heating element\u003c\/strong\u003e, always handle the unit by the ceramic base to prevent skin oils from causing localized hotspots and premature fractures.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Acts as a direct 120VAC replacement for a wide range of OEM carbide-style ignitors in residential and commercial heating equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e High-grade lead insulation rated for 200°C prevents wire degradation in high-heat plenum environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Connection:\u003c\/strong\u003e Equipped with a \u003cstrong\u003eMolex side lock connector\u003c\/strong\u003e and 0.092\" pins to ensure vibration-resistant electrical contact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Timing:\u003c\/strong\u003e Validated for use with various \u003cstrong\u003eHot Surface Ignition (HSI) systems\u003c\/strong\u003e, including 15, 17, and 45-second warm-up cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eN-Style Mounting:\u003c\/strong\u003e Standardized mounting configuration simplifies installation in tight burner compartments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 767A-372 compatible with my specific furnace brand?\u003c\/strong\u003e\u003cbr\u003e\nThis ignitor is a common \u003cstrong\u003edirect replacement\u003c\/strong\u003e for many Rheem, Lennox, and Trane models. Check your existing lead length and connector style; the 767A-372 utilizes 5 1\/4\" leads and a side-locking Molex plug.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I touch the black element during installation?\u003c\/strong\u003e\u003cbr\u003e\nNo. You must handle the \u003cstrong\u003ehot surface ignitor\u003c\/strong\u003e only by its ceramic base. Oils from your hands can cause the silicon carbide to fail shortly after the first few heat cycles.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat if my old connector doesn't match?\u003c\/strong\u003e\u003cbr\u003e\nWhile this unit includes a specific Molex connector, it is often supplied with ceramic wire nuts to allow for \"cut and strip\" connections if the terminal housing differs from your original harness.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644171020,"sku":"767A-372","price":20.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_7497a5af-fb40-4673-b8de-6e6509c88400.png?v=1756165175"},{"product_id":"copeland-comfort-control-white-rodgers-767a-369-ignitor","title":"Copeland Comfort Control (White Rodgers) 767A-369 Ignitor","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 767A-369\u003c\/strong\u003e is a high-performance \u003cstrong\u003esilicon carbide hot surface ignitor\u003c\/strong\u003e designed for professional-grade furnace repairs. This 120V component serves as a \u003cstrong\u003edirect replacement for D9918202A\u003c\/strong\u003e, as well as Amana B1336102 and Norton 201A models. Featuring a durable carbide element and an \u003cstrong\u003eA-style mounting block\u003c\/strong\u003e, it provides consistent ignition in sealed combustion environments. The assembly comes equipped with \u003cstrong\u003e5.5-inch lead wires\u003c\/strong\u003e and a \u003cstrong\u003eMolex internally keyed connector\u003c\/strong\u003e with .093-inch male pins for a secure electrical interface. Engineered to withstand demanding thermal cycles, the leads are insulated to 200°C to prevent premature degradation. For contractors, this unit ensures \u003cstrong\u003eOEM furnace ignitor\u003c\/strong\u003e performance across various platforms, including Amana, Lennox, and Goodman systems, effectively reducing callbacks through reliable 15, 17, or 45-second ignition timings.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Serves as a \u003cstrong\u003e120V HSI replacement\u003c\/strong\u003e for multiple OEM part numbers, including Robertshaw 41-401 and Honeywell Q4100C9042.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e High-density \u003cstrong\u003esilicon carbide\u003c\/strong\u003e material resists oxidation and ensures rapid heat-up for efficient gas ignition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Fitment:\u003c\/strong\u003e Features an \u003cstrong\u003eA-style mounting\u003c\/strong\u003e base and specific lead length for exact replacement in tight burner compartments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Insulation:\u003c\/strong\u003e High-temperature fiberglass lead insulation rated for 200°C protects against internal furnace heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is the resistance of the 767A-369?\u003c\/strong\u003e This \u003cstrong\u003ehot surface ignitor\u003c\/strong\u003e typically shows a cold resistance between 50 and 1100 Ohms, depending on the specific diagnostic environment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan this be used in sealed combustion units?\u003c\/strong\u003e Yes, the \u003cstrong\u003e767A-369\u003c\/strong\u003e is rated for use in sealed combustion systems and is a standard choice for high-efficiency furnaces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes it include mounting hardware?\u003c\/strong\u003e This model utilizes the integrated A-style block for mounting; however, it is recommended to retain original brackets for specific cabinet configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644213708,"sku":"767A-369","price":23.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_e0ccc442-38f0-4d54-b868-683a4ffcda6d.png?v=1756165174"},{"product_id":"copeland-comfort-control-white-rodgers-3l09-20-limit-switch","title":"Copeland Comfort Control (White Rodgers) 3L09-20 Limit Switch","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 3L09-20 Limit Switch\u003c\/strong\u003e is a professional-grade \u003cstrong\u003e1\/2\" bimetal disc limit control\u003c\/strong\u003e designed for high-limit temperature protection in forced air heating systems. This \u003cstrong\u003eboard mounted limit switch\u003c\/strong\u003e features a \u003cstrong\u003e7.12\" insertion length\u003c\/strong\u003e, ensuring the sensing element is positioned deep within the air stream for rapid thermal response and precise high-speed contact separation. Operating as a \u003cstrong\u003enormally closed SPST switch\u003c\/strong\u003e, the \u003cstrong\u003e3L09-20\u003c\/strong\u003e is engineered with an \u003cstrong\u003eopen on rise\u003c\/strong\u003e action that triggers at a fixed 240°F and utilizes an \u003cstrong\u003eauto reset\u003c\/strong\u003e function once the temperature drops to the 210°F close point.\u003c\/p\u003e\n\n\u003cp\u003eFor contractors performing field repairs, this unit serves as the \u003cstrong\u003edirect replacement for 86H73\u003c\/strong\u003e and is compatible with various OEM HVAC equipment configurations. The robust \u003cstrong\u003ephenolic housing\u003c\/strong\u003e and 1\/2\" snap disc design prioritize long-term performance and reliability in high-cycle furnace applications. Whether you are troubleshooting air flow issues or replacing a fatigued \u003cstrong\u003ehigh limit sensor\u003c\/strong\u003e, the \u003cstrong\u003e3L09-20\u003c\/strong\u003e provides the exact \u003cstrong\u003efixed temperature settings\u003c\/strong\u003e required to maintain system safety and ASHRAE compliance. This control handles standard pilot duty and power loads typical in residential and light commercial air handlers.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Serves as a reliable \u003cstrong\u003e86H73 cross reference\u003c\/strong\u003e and fits numerous HVAC board-mount footprints.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Calibration:\u003c\/strong\u003e Fixed 240°F open and 210°F close temperatures prevent nuisance tripping while ensuring safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Reach:\u003c\/strong\u003e The \u003cstrong\u003e7.12-inch probe length\u003c\/strong\u003e allows for accurate temperature monitoring in larger heat exchanger plenums.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Build:\u003c\/strong\u003e Features a high-speed bimetal disc for crisp switching and minimized electrical arcing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Recovery:\u003c\/strong\u003e The \u003cstrong\u003eauto reset limit switch\u003c\/strong\u003e design restores circuit continuity without manual intervention after cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions \u0026amp; Technical Support\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs the 3L09-20 a manual or auto reset switch?\u003c\/strong\u003e This model is an \u003cstrong\u003eauto reset\u003c\/strong\u003e control, meaning it will automatically close the circuit once the plenum temperature falls below 210°F.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I use this to replace a shorter insertion limit?\u003c\/strong\u003e You must match the \u003cstrong\u003e7.12\" insertion length\u003c\/strong\u003e of the original part to ensure the sensor reaches the correct thermal zone; a shorter probe may cause delayed response times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWill this work on 24V and 120V circuits?\u003c\/strong\u003e Yes, this \u003cstrong\u003esnap disc limit\u003c\/strong\u003e is rated for use across common heating control voltages, including 24V, 120V, and 240V AC applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644220684,"sku":"3L09-20","price":20.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/1_2caed18a-dbad-4922-b6d6-639c364b8160.jpg?v=1756165173"},{"product_id":"copeland-comfort-control-white-rodgers-767a-371-ignitor","title":"Copeland Comfort Control (White Rodgers) 767A-371 Ignitor","description":"\u003cp\u003eOptimizing 120V ignition systems requires the precision of a genuine \u003cstrong\u003eWhite Rodgers 767A-371 Ignitor\u003c\/strong\u003e. This \u003cstrong\u003esilicon carbide hot surface ignitor\u003c\/strong\u003e is engineered as a high-performance direct replacement for mission-critical heating equipment across major brands like Goodman, York, Rheem, and Trane. Built for durability, the \u003cstrong\u003e767A-371\u003c\/strong\u003e features a robust \u003cstrong\u003esilicon carbide element\u003c\/strong\u003e designed to withstand the thermal stress of 15, 17, or 45-second ignition cycles. This model comes with \u003cstrong\u003e19 1\/8 inch leads\u003c\/strong\u003e with stripped ends and a specialized \u003cstrong\u003eW-style mounting block\u003c\/strong\u003e, ensuring a secure and exact fit in tight furnace cabinets. For service technicians, this \u003cstrong\u003eOEM furnace ignitor\u003c\/strong\u003e is a versatile truck-stock item, cross-referencing over a dozen specialized part numbers including Robertshaw 41-402 and Norton 201 series. By maintaining 120V hot surface ignition standards, it provides consistent amperage draw and surface temperature for reliable gas ignition in residential and light commercial forced-air systems.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefit List:\u003c\/strong\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBroad Brand Compatibility:\u003c\/strong\u003e Direct fit for Goodman, Amana, Nordyne, Rheem, Ruud, and Armstrong heating units.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eW-Style Mounting:\u003c\/strong\u003e Purpose-built mounting block simplifies installation in specific OEM burner configurations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Temperature Insulation:\u003c\/strong\u003e Equipped with 19 1\/8\" leads rated for 200°C to prevent wire degradation near the combustion chamber.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUniversal Field Support:\u003c\/strong\u003e Package includes ceramic wire nuts to facilitate cut-and-strip connections for non-standard harness plugs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecision Engineering:\u003c\/strong\u003e Optimized for 120V AC systems, delivering the exact wattage needed for rapid \u003cstrong\u003ehot surface ignition\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the 767A-371 and other 767A series ignitors?\u003c\/strong\u003e\u003cbr\u003e\nThe 767A-371 is distinguished by its specific \u003cstrong\u003eW-style mounting\u003c\/strong\u003e bracket and extra-long 19 1\/8\" leads. While many 767A ignitors share the same \u003cstrong\u003esilicon carbide\u003c\/strong\u003e chemistry, the mounting footprint and lead length are critical for ensuring the element is positioned correctly within the burner flame path.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I touch the silicon carbide element during installation?\u003c\/strong\u003e\u003cbr\u003e\nNo. Skin oils can create hot spots on the carbide surface, leading to localized stress and premature element fracture. Always handle the ignitor by the \u003cstrong\u003eceramic base\u003c\/strong\u003e or use clean gloves during the replacement process.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this ignitor work with 80V ignition systems?\u003c\/strong\u003e\u003cbr\u003e\nNo, the 767A-371 is a \u003cstrong\u003e120V hot surface ignitor\u003c\/strong\u003e. Installing a 120V carbide element into an 80V circuit will result in inadequate heating and ignition failure. Always verify the control board voltage output before selecting a replacement.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644232780,"sku":"767A-371","price":22.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_eec01f1b-4f67-408d-b143-4c3b758214d3.png?v=1756165173"},{"product_id":"copeland-comfort-control-white-rodgers-3f05-1-temperature-control","title":"Copeland Comfort Control (White Rodgers) 3F05-1 Temperature Control","description":"\u003cp\u003eThe \u003cstrong\u003eWhite Rodgers 3F05-1\u003c\/strong\u003e is a professional-grade \u003cstrong\u003eadjustable fan control\u003c\/strong\u003e engineered to replace a wide variety of \u003cstrong\u003efixed snap disc\u003c\/strong\u003e thermostats in HVAC systems and heating appliances. This \u003cstrong\u003eSPST close on rise\u003c\/strong\u003e temperature control features an adjustable range of \u003cstrong\u003e90 to 130 degrees F\u003c\/strong\u003e, allowing technicians to fine-tune fan cycling for optimal performance. Designed as a rugged \u003cstrong\u003esnap disc auto reset fan switch\u003c\/strong\u003e, it utilizes a \u003cstrong\u003e74T12-310708\u003c\/strong\u003e style therm-o-disc for reliable operational consistency. With a fixed \u003cstrong\u003e20 degree F differential\u003c\/strong\u003e, this \u003cstrong\u003eHVAC temperature switch\u003c\/strong\u003e ensures the blower motor engages and disengages at precise intervals. It serves as the direct replacement for the \u003cstrong\u003e3F05-3\u003c\/strong\u003e and various \u003cstrong\u003eTherm-O-Disc Style 310708\u003c\/strong\u003e models, making it an essential service truck item to reduce inventory complexity. The inclusion of \u003cstrong\u003equick connect terminals\u003c\/strong\u003e facilitates rapid field installation, while the \u003cstrong\u003eType 74T12\u003c\/strong\u003e construction provides long-term durability in high-demand heating applications.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Versatility:\u003c\/strong\u003e Consolidates truck stock by replacing multiple fixed-temperature snap disc models with one \u003cstrong\u003eadjustable temperature range control\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Fan Cycling:\u003c\/strong\u003e The \u003cstrong\u003eclose on rise switch action\u003c\/strong\u003e ensures the blower activates exactly when the plenum reaches the set point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Installation:\u003c\/strong\u003e Features 1\/4-inch \u003cstrong\u003equick connect terminals\u003c\/strong\u003e for seamless integration into existing wiring harnesses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Reset:\u003c\/strong\u003e The \u003cstrong\u003eauto reset\u003c\/strong\u003e functionality eliminates manual intervention after a high-temperature cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions \u0026amp; Answers\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3F05-1 a suitable replacement for a furnace limit switch?\u003c\/strong\u003e\u003cbr\u003e\nNo, this unit is a \u003cstrong\u003eclose on rise\u003c\/strong\u003e fan control. Limit switches typically require an open on rise action for safety. Always verify if your application requires the fan to turn on (3F05 series) or the burner to turn off (3L05 series) at the temperature set point.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow do I adjust the temperature set point on this control?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eWhite Rodgers 3F05-1\u003c\/strong\u003e features a calibrated dial on the face of the disc. Use a screwdriver to align the desired turn-on temperature with the indicator mark before mounting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill this replace a 3F05-3 model?\u003c\/strong\u003e\u003cbr\u003e\nYes, the \u003cstrong\u003e3F05-1\u003c\/strong\u003e is the official direct replacement for the legacy \u003cstrong\u003e3F05-3\u003c\/strong\u003e model, maintaining the same electrical ratings and physical mounting footprint.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644246028,"sku":"3F05-1","price":20.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_d1bd0c71-88dc-4977-94a7-337131c5eabb.png?v=1756165172"},{"product_id":"copeland-comfort-control-alco-047607-filter-drier","title":"Copeland Comfort Control (Alco) 047607 Filter Drier","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (Alco) 047607 Filter Drier\u003c\/strong\u003e, commonly known by its model number \u003cstrong\u003eEK-083\u003c\/strong\u003e, is a premium \u003cstrong\u003eliquid line filter drier\u003c\/strong\u003e engineered for critical moisture and acid removal in refrigeration and HVAC systems. Built with a \u003cstrong\u003ecompacted bead desiccant\u003c\/strong\u003e, this unit prioritizes filtration first to maximize the available surface area of the desiccant blend, which is specifically optimized for high water and acid capacity. This internal design ensures the \u003cstrong\u003e20-micron filtration\u003c\/strong\u003e outlet pad remains effective, preventing debris from migrating through the system and protecting sensitive components like expansion valves and \u003cstrong\u003eCopeland compressors\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis \u003cstrong\u003e8 cubic inch\u003c\/strong\u003e drier features a rugged, \u003cstrong\u003eshock-resistant steel shell\u003c\/strong\u003e finished with corrosion-resistant epoxy powder paint. It is equipped with \u003cstrong\u003e3\/8\" SAE flare\u003c\/strong\u003e solid copper connections, allowing for straightforward installation without the need for brazing in tight quarters. Rated for a \u003cstrong\u003e680 PSI maximum pressure\u003c\/strong\u003e, the \u003cstrong\u003eEK-083\u003c\/strong\u003e is a universal replacement component compatible with a wide range of refrigerants, including \u003cstrong\u003eR-410A, R-22, R-134a, R-404A\u003c\/strong\u003e, and many other CFC, HCFC, and HFC blends. Its approval for use with \u003cstrong\u003ePOE oils\u003c\/strong\u003e makes it a standard choice for modern high-efficiency replacements and system retrofits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Refrigerant Compatibility:\u003c\/strong\u003e Suitable for modern high-pressure systems using \u003cstrong\u003eR-410A\u003c\/strong\u003e as well as legacy \u003cstrong\u003eR-22\u003c\/strong\u003e and \u003cstrong\u003eR-134a\u003c\/strong\u003e applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Contaminant Control:\u003c\/strong\u003e High moisture and acid removal capacity prevents the formation of corrosive sludge that leads to motor burnout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Filtration:\u003c\/strong\u003e The \u003cstrong\u003e20-micron outlet pad\u003c\/strong\u003e captures smaller particulates than standard block-style driers, extending the life of the thermal expansion valve (TXV).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e The epoxy-coated \u003cstrong\u003eshock-resistant steel shell\u003c\/strong\u003e provides longevity in harsh outdoor environments and marine applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEase of Service:\u003c\/strong\u003e \u003cstrong\u003e3\/8\" SAE flare\u003c\/strong\u003e fittings eliminate the risks associated with field brazing, reducing the total time on the job site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions Regarding the EK-083:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the tonnage rating for this filter drier?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eEK-083\u003c\/strong\u003e is typically used in systems ranging from \u003cstrong\u003e3\/4 to 2-1\/2 tons\u003c\/strong\u003e, though actual flow capacity depends on the specific refrigerant and pressure drop requirements of your system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the EK-083 compatible with POE oil?\u003c\/strong\u003e\u003cbr\u003e\nYes, the desiccant blend and internal components are specifically approved for use with \u003cstrong\u003ePOE oils\u003c\/strong\u003e and \u003cstrong\u003eCopeland compressors\u003c\/strong\u003e, ensuring material compatibility and system integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this be used on the suction line?\u003c\/strong\u003e\u003cbr\u003e\nNo, this is a \u003cstrong\u003eliquid line filter drier\u003c\/strong\u003e specifically designed for the high-pressure side of the system. For suction line protection after a burnout, a dedicated suction line drier is required.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (Alco)","offers":[{"title":"Default Title","offer_id":35644251084,"sku":"47607","price":19.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_e9d398f5-b0f2-4225-b524-9108b01dd164.png?v=1760630844"},{"product_id":"copeland-comfort-control-alco-047608-filter-drier","title":"Copeland Comfort Control (Alco) 047608 Filter Drier","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (Alco) 047608 Filter Drier\u003c\/strong\u003e, also identified as the \u003cstrong\u003eModel EK083S\u003c\/strong\u003e, is a high-performance \u003cstrong\u003eliquid line filter drier\u003c\/strong\u003e engineered for critical moisture and acid removal in refrigeration and air conditioning systems. Featuring a \u003cstrong\u003e3\/8\" sweat ODF connection\u003c\/strong\u003e and an \u003cstrong\u003e8 cubic inch\u003c\/strong\u003e desiccant volume, this unit utilizes a premium compacted bead core to maximize surface area contact. The \u003cstrong\u003eEK-083S\u003c\/strong\u003e provides exceptional filtration down to \u003cstrong\u003e20 microns\u003c\/strong\u003e, protecting expansion valves and compressors from particulate contaminants. With a \u003cstrong\u003emaximum working pressure of 680 PSIG\u003c\/strong\u003e, it is fully compatible with high-pressure refrigerants, including \u003cstrong\u003eR-410A\u003c\/strong\u003e, while maintaining efficiency with \u003cstrong\u003eR-22, R-134a, R-404A, and R-507\u003c\/strong\u003e. Its \u003cstrong\u003eshock-resistant steel shell\u003c\/strong\u003e and epoxy powder coating ensure durability in demanding mechanical environments, while the solid copper fittings simplify brazing during installation. This \u003cstrong\u003eAlco EK series\u003c\/strong\u003e drier is the professional standard for technicians requiring reliable system dehydration and POE oil compatibility.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Benefits for HVAC Professionals\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Refrigerant Compatibility:\u003c\/strong\u003e Rated for use with CFC, HCFC, and HFC refrigerants, providing a versatile solution for various system retrofits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Filtration:\u003c\/strong\u003e The 20-micron outlet pad prevents debris from reaching sensitive metering devices, reducing service callbacks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Moisture Removal:\u003c\/strong\u003e Optimized desiccant blend ensures maximum water and acid capacity to prevent internal corrosion and oil breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e The shock-protected bead core maintains structural integrity under vibration, preventing desiccant bypass.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Connections:\u003c\/strong\u003e Features 100% solid copper ODF fittings for rapid, leak-free brazing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 047608 Filter Drier compatible with POE oils?\u003c\/strong\u003e\u003cbr\u003e\nYes, the EK083S is specifically designed and approved for use with POE oils in systems utilizing Copeland compressors or other major manufacturer platforms.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum pressure rating for this liquid line drier?\u003c\/strong\u003e\u003cbr\u003e\nThe unit is rated for a maximum internal working pressure of 680 PSIG, making it suitable for modern high-pressure R-410A applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAre the connections flare or sweat?\u003c\/strong\u003e\u003cbr\u003e\nThe Model 047608 (EK083S) features 3\/8\" sweat (ODF) connections for professional brazed installations.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (Alco)","offers":[{"title":"Default Title","offer_id":35644252428,"sku":"47608","price":18.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_72a6d255-df64-4b40-9cc8-d68b1f631f62.png?v=1764226204"},{"product_id":"white-rodgers-h06f-36-thermocouple","title":"Copeland Comfort Control (White Rodgers) H06F-36 Thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) H06F-36 Thermocouple\u003c\/strong\u003e is a professional-grade replacement engineered for high-demand gas pilot applications requiring integrated safety circuits. This 36-inch \u003cstrong\u003ejunction block thermocouple\u003c\/strong\u003e features a specialized 11\/32-32 male nut and a double-lead configuration, specifically designed to interface with \u003cstrong\u003eEnergy Cut-Off (ECO)\u003c\/strong\u003e safety switches. Constructed with a \u003cstrong\u003estainless steel element\u003c\/strong\u003e, this unit provides maximum durability against high-temperature oxidation in the combustion chamber, ensuring consistent millivolt output within the standard 22-30mV range. As a veteran technician knows, the H06F series is the go-to for \u003cstrong\u003euniversal thermocouple replacement\u003c\/strong\u003e in furnaces, water heaters, and space heaters, offering a reliable fit for most OEM pilot burners when used with the included \u003cstrong\u003euniversal adapter fittings\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eECO Compatibility:\u003c\/strong\u003e Features a dedicated junction block for seamless integration with Energy Cut-Off switches to prevent overheating.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Service Life:\u003c\/strong\u003e High-grade \u003cstrong\u003estainless steel construction\u003c\/strong\u003e resists scaling and corrosion under constant pilot flame exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Application:\u003c\/strong\u003e Serves as a direct-fit or universal substitute for \u003cstrong\u003eWhite Rodgers\u003c\/strong\u003e, Honeywell, Johnson, and Robertshaw 36-inch thermocouples.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimple Integration:\u003c\/strong\u003e Includes a kit of \u003cstrong\u003euniversal adapter fittings\u003c\/strong\u003e to match various burner bracket styles without field modifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Millivolt Signal:\u003c\/strong\u003e Provides a stable voltage to the gas valve magnet, reducing nuisance pilot dropouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Answers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the H06F-36 if my original part did not have an ECO connection?\u003c\/strong\u003e\u003cbr\u003e\nThe \u003cstrong\u003eH06F-36 junction block\u003c\/strong\u003e is designed specifically for systems with an ECO high-limit circuit. If your valve does not utilize an ECO, you should typically use the H06E series; however, many technicians prefer the H06F for its flexibility in modern safety-equipped appliances.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum temperature rating for the hot junction?\u003c\/strong\u003e\u003cbr\u003e\nThis \u003cstrong\u003e36-inch thermocouple\u003c\/strong\u003e is rated for a maximum hot junction temperature of 1450°F, making it suitable for high-intensity natural gas and propane pilot assemblies.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow tight should the 11\/32\" connection be at the gas control?\u003c\/strong\u003e\u003cbr\u003e\nFor a proper electrical path, thread the nut into the gas control until finger-tight, then provide an additional 1\/4 turn with a wrench. Over-tightening can damage the internal insulation and cause signal failure.\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35644298124,"sku":"H06F-36","price":23.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_af4a59bd-f7ba-4fc2-9fda-5ed7444cf620.jpg?v=1756165171"},{"product_id":"copeland-comfort-control-alco-047609-filter-drier","title":"Copeland Comfort Control (Alco) 047609 Filter Drier","description":"\u003cp data-start=\"0\" data-end=\"359\"\u003eThe Copeland Comfort Control (Alco) 047609 liquid line filter drier (Model EK084) is designed to protect refrigeration and air conditioning systems by removing moisture, acids, and solid contaminants from the refrigerant stream. This liquid line filter drier features a 1\/2\" flare connection for secure installation in residential and commercial HVAC systems.\u003c\/p\u003e\n\u003cp data-start=\"361\" data-end=\"698\"\u003eWith an 8 cubic inch core and 20-micron filtration capability, this HVAC filter drier provides effective system cleanup and long-term protection of compressors, expansion valves, and other critical components. Rated for a maximum working pressure of 680 PSI, it is suitable for high-pressure refrigerants commonly used in modern systems.\u003c\/p\u003e\n\u003cp data-start=\"700\" data-end=\"989\"\u003eThis Copeland EK084 filter drier is widely used in both new installations and service replacements, especially after system repairs where moisture and debris contamination is a concern. Proper installation in the liquid line ensures optimal refrigerant conditioning and system reliability.\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1004\"\u003eKey Features:\u003c\/p\u003e\n\u003cul data-start=\"1005\" data-end=\"1275\"\u003e\n\u003cli data-section-id=\"1nurbdx\" data-start=\"1005\" data-end=\"1052\"\u003e1\/2\" flare connection for easy installation\u003c\/li\u003e\n\u003cli data-section-id=\"152zs6j\" data-start=\"1053\" data-end=\"1114\"\u003e8 cubic inch core for effective moisture and acid removal\u003c\/li\u003e\n\u003cli data-section-id=\"12rhre4\" data-start=\"1115\" data-end=\"1169\"\u003e20-micron filtration for solid contaminant control\u003c\/li\u003e\n\u003cli data-section-id=\"y0b5jr\" data-start=\"1170\" data-end=\"1213\"\u003e680 PSI maximum working pressure rating\u003c\/li\u003e\n\u003cli data-section-id=\"6p26ky\" data-start=\"1214\" data-end=\"1275\"\u003eSuitable for residential and commercial HVAC applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1277\" data-end=\"1472\"\u003eCommon Questions:\u003cbr\u003eIs this filter drier compatible with modern refrigerants? Can it be used after compressor burnout cleanup? Does the 1\/2\" flare connection fit standard liquid line installations?\u003c\/p\u003e\n\u003cp data-start=\"1474\" data-end=\"1664\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (Alco)","offers":[{"title":"Default Title","offer_id":35644322956,"sku":"47609","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Pic_123f9327-c75d-47cc-8697-9d76578871b7.png?v=1775750904"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/collections\/Pic_ce02e830-d0d6-4beb-b62a-d1000b71594e.png?v=1743446011","url":"https:\/\/www.gsistore.com\/en-ca\/collections\/copeland.oembed?page=40","provider":"GSIstore","version":"1.0","type":"link"}