{"title":"REFRIGERANT","description":"","products":[{"product_id":"r-410a","title":"R-410A 25 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eThis 25 lb. cylinder contains factory-sealed, \u003cstrong\u003e100% virgin R-410A refrigerant\u003c\/strong\u003e, the industry-standard HFC blend for modern residential and commercial HVAC systems. As a near-azeotropic mixture of 50% R-32 and 50% R-125, \u003cstrong\u003eR-410A gas\u003c\/strong\u003e offers high heat transfer coefficients and superior thermodynamic performance compared to legacy HCFCs. Operating at higher pressures than R-22, this \u003cstrong\u003enon-ozone depleting refrigerant\u003c\/strong\u003e requires \u003cstrong\u003ePOE (Polyolester) lubricant\u003c\/strong\u003e for proper oil return and compressor reliability. Designed for use in systems labeled \u003cstrong\u003eAZ-20, Puron, or Suva 9100\u003c\/strong\u003e, it features an ASHRAE A1 safety classification, ensuring low toxicity and no flame propagation. When performing a \u003cstrong\u003erefrigerant recharge\u003c\/strong\u003e or installing new split systems and heat pumps, utilizing \u003cstrong\u003evirgin R-410A\u003c\/strong\u003e ensures the absence of contaminants or non-condensables that compromise subcooling and superheat readings. Ensure all recovery and manifold equipment is rated for the 4.94 MPa critical pressure of this \u003cstrong\u003ehigh-efficiency refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum System Efficiency:\u003c\/strong\u003e High heat transfer properties allow for more compact heat exchanger designs and optimized \u003cstrong\u003eSEER ratings\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Longevity:\u003c\/strong\u003e Using \u003cstrong\u003evirgin R-410A 25 lbs\u003c\/strong\u003e cylinders prevents the introduction of moisture or mixed gases often found in low-quality reclaimed batches.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZero Ozone Depletion:\u003c\/strong\u003e Fully compliant with EPA regulations as a sustainable replacement for R-22 in \u003cstrong\u003enew HVAC installations\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStable Pressure-Temperature Relationship:\u003c\/strong\u003e Near-azeotropic behavior minimizes glide, allowing for accurate \u003cstrong\u003echarging by weight\u003c\/strong\u003e or subcooling methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Contractor Questions:\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003eCan R-410A be used to retrofit an existing R-22 system?\u003c\/strong\u003e\u003cbr\u003e\nNo. \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e operates at significantly higher pressures (approximately 50% to 70% higher) and requires specific \u003cstrong\u003ePOE oil\u003c\/strong\u003e. Charging R-410A into an R-22 system will lead to catastrophic component failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs an EPA 608 certification required for purchase?\u003c\/strong\u003e\u003cbr\u003e\nYes. To purchase \u003cstrong\u003ewholesale R-410A refrigerant\u003c\/strong\u003e, you must provide a valid \u003cstrong\u003eEPA 608 License\u003c\/strong\u003e or a Resale Statement in accordance with federal law. This product is restricted to the Lower 48 states.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the proper charging method for this HFC blend?\u003c\/strong\u003e\u003cbr\u003e\nBecause R-410A is a blend, it should always be removed from the cylinder in the \u003cstrong\u003eliquid phase\u003c\/strong\u003e to prevent fractionation and ensure the correct 50\/50 chemical composition enters the system.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":35648479116,"sku":"R-410A","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/r410a.jpg?v=1777655119"},{"product_id":"r-22","title":"R-22 30 Lbs Refrigerant Factory Sealed Gas","description":"\u003cp\u003eThis factory-sealed 30 lb. cylinder of \u003cstrong\u003eR-22 refrigerant\u003c\/strong\u003e provides chlorodifluoromethane (HCFC-22) for the maintenance and service of existing residential and commercial HVAC systems. As a veteran-grade \u003cstrong\u003eR22 30 lbs\u003c\/strong\u003e solution, this gas maintains the thermodynamic properties required for older air conditioning units, heat pumps, and medium-to-low temperature refrigeration systems. With the \u003cstrong\u003eHCFC phase-out\u003c\/strong\u003e limiting production, sourcing reclaimed or virgin stock that meets AHRI-700 standards is essential for system longevity and efficiency. This cylinder features the standard 1\/4\" SAE flare connection and is designed for liquid or vapor charging depending on system requirements. Utilizing \u003cstrong\u003evirgin R22 gas\u003c\/strong\u003e ensures standard operating pressures and prevents the compressor oil contamination often associated with poor-quality blends. Always verify \u003cstrong\u003eR22 refrigeration\u003c\/strong\u003e system compatibility and charge by weight to maintain subcooling and superheat targets for optimal heat transfer and evaporator performance.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-sealed 30 lb. cylinder\u003c\/strong\u003e ensures moisture-free contents for system stability.\u003c\/li\u003e\n\u003cli\u003eCompatible with traditional mineral oil (MO) and alkylbenzene (AB) lubricants commonly found in legacy \u003cstrong\u003eR-22 systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eProvides excellent volumetric cooling capacity and energy efficiency for \u003cstrong\u003eresidential AC repair\u003c\/strong\u003e and commercial retrofits.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEssential for maintaining systems where a full 407C or 422B retrofit is not yet feasible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs an EPA 608 certification required to purchase this refrigerant?\u003c\/strong\u003e\u003cbr\u003eYes, per EPA Section 608 regulations, buyers must provide a valid HVAC technician certification or a resale statement to complete the purchase of \u003cstrong\u003eR-22 cylinders\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this R-22 gas to top off a system currently running a drop-in replacement?\u003c\/strong\u003e\u003cbr\u003eNo, \u003cstrong\u003eR-22 refrigerant\u003c\/strong\u003e should never be mixed with HFC blends or drop-in replacements like R-407C. Mixing refrigerants causes pressure deviations and can lead to catastrophic compressor failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cylinder ship to all 50 states?\u003c\/strong\u003e\u003cbr\u003eDue to hazardous material regulations and shipping constraints, this product is available for ground shipping to the lower 48 states only.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":35657463436,"sku":"R-22","price":950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/R22_f2bfabcc-18ea-48f2-9858-81d6cce4d442.webp?v=1747247365"},{"product_id":"refrigerant-r-407c","title":"R-407C 25 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eFor veteran technicians looking for a \u003cstrong\u003evirgin R-407C refrigerant\u003c\/strong\u003e to handle R-22 retrofits, this 25 lb factory-sealed cylinder provides the high-purity HFC blend required for consistent performance. As a zeotropic blend of \u003cstrong\u003eR-32, R-125, and R-134a\u003c\/strong\u003e (23\/25\/52 wt%), R-407C is the primary \u003cstrong\u003eOEM-approved R-22 replacement\u003c\/strong\u003e for positive displacement air conditioning and heat pump systems. It mirrors the pressure-temperature characteristics of HCFC-22 more closely than other alternatives, though professionals should account for a \u003cstrong\u003etemperature glide\u003c\/strong\u003e of approximately 10°F during the charging process. This refrigerant is \u003cstrong\u003e100% virgin gas\u003c\/strong\u003e, meeting ARI-700 standards to ensure no cross-contamination or non-condensables interfere with system efficiency. When performing a conversion, remember that R-407C is \u003cstrong\u003eimmiscible with mineral oil\u003c\/strong\u003e; it requires a complete changeover to \u003cstrong\u003ePOE lubricant\u003c\/strong\u003e (typically targeting \u0026lt;5% residual mineral oil) to ensure proper oil return and compressor longevity. This \u003cstrong\u003efactory-sealed R407C 25 lbs\u003c\/strong\u003e cylinder is the industry standard for maintaining legacy commercial and residential DX equipment while staying compliant with ozone-protection regulations.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect R-22 Retrofit:\u003c\/strong\u003e Functions as the leading \u003cstrong\u003ereplacement for R-22 refrigerant\u003c\/strong\u003e in residential and commercial AC systems with minimal component changes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Thermodynamic Efficiency:\u003c\/strong\u003e Offers superior heat transfer properties and energy efficiency comparable to HCFC-22.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmentally Conscious:\u003c\/strong\u003e Zero Ozone Depletion Potential (ODP) and a Global Warming Potential (GWP) of approximately 1774, aligning with current environmental standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafe and Stable:\u003c\/strong\u003e Classified as ASHRAE A1 (non-flammable and low toxicity) for reliable use in standard HVAC applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad Application:\u003c\/strong\u003e Suitable for use in \u003cstrong\u003edry expansion (DX) air conditioning\u003c\/strong\u003e, heat pumps, and medium-temperature refrigeration systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions About R-407C\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I top off an R-22 system with R-407C?\u003c\/strong\u003e\u003cbr\u003e\nNo, \u003cstrong\u003eR-407C cannot be mixed with R-22\u003c\/strong\u003e. Mixing refrigerants creates an unknown zeotropic blend that varies in pressure and temperature, potentially damaging the compressor and metering devices. The system must be fully evacuated before charging with \u003cstrong\u003e100% virgin R-407C\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo I need to change the oil when switching to R-407C?\u003c\/strong\u003e\u003cbr\u003e\nYes. R-407C requires \u003cstrong\u003epolyolester (POE) oil\u003c\/strong\u003e for proper lubrication. Because R-407C does not mix with the mineral oil or alkylbenzene oil used in old R-22 systems, failing to flush the oil will result in oil logging in the evaporator and eventual compressor failure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should R-407C be charged into a system?\u003c\/strong\u003e\u003cbr\u003e\nSince R-407C is a zeotropic blend with significant glide, it \u003cstrong\u003emust be charged as a liquid\u003c\/strong\u003e from the cylinder. Charging as a vapor can cause fractionation, altering the chemical composition of the refrigerant remaining in the tank and the gas entering the system.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":18216036565107,"sku":"R-407C","price":231.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/aa_275ac646-8448-4fc0-ad7a-1d9f962567ec.jpg?v=1578594427"},{"product_id":"refrigerant-r-407a","title":"R-407A 25 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eThis \u003cstrong\u003eR-407A 25 lbs refrigerant\u003c\/strong\u003e is an ARI-700 certified \u003cstrong\u003e100% virgin refrigerant\u003c\/strong\u003e, designed as a reliable HFC blend for mid to low-temperature refrigeration systems. As an OEM-approved \u003cstrong\u003eR22 replacement for refrigeration\u003c\/strong\u003e, R-407A offers a significantly lower global warming potential (GWP) than R-404A or R-507, making it an efficient choice for retrofitting existing systems. Featuring a unique blend of R-32, R-125, and R-134a, this gas provides excellent mass flow and discharge temperatures comparable to R-22. Technicians should note that R-407A requires \u003cstrong\u003ePOE oil\u003c\/strong\u003e (polyolester) for proper lubrication and compressor health. It is engineered for use in supermarket racks, cold storage, and commercial reach-ins, ensuring high thermal stability and consistent \u003cstrong\u003eHVAC cooling performance\u003c\/strong\u003e across a wide operating envelope. This factory-sealed cylinder ensures purity and prevents moisture contamination, critical for maintaining \u003cstrong\u003erefrigeration efficiency\u003c\/strong\u003e and system longevity in commercial environments.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Cooling Capacity:\u003c\/strong\u003e Delivers thermal performance and mass flow rates similar to R-22, ensuring system stability in diverse ambient conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSustainable HFC Blend:\u003c\/strong\u003e Offers a lower GWP than R-404A, assisting contractors in meeting tightening environmental regulations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Application:\u003c\/strong\u003e Ideal for both medium and low-temperature refrigeration cycles found in commercial and industrial settings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePure Virgin Gas:\u003c\/strong\u003e Guaranteed ARI-700 purity levels to prevent non-condensable buildup and expansion valve fouling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Retrofit Path:\u003c\/strong\u003e Compatible with many existing R-22 components following an oil change to \u003cstrong\u003esynthetic POE lubricant\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs R-407A a direct drop-in for R-22?\u003c\/strong\u003e\u003cbr\u003e\nWhile R-407A is a highly compatible retrofit, it is not a \"drop-in.\" Technicians must replace mineral or alkylbenzene oils with POE oil and may need to adjust expansion valve settings to account for different pressure-temperature characteristics.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I top off an R-404A system with R-407A?\u003c\/strong\u003e\u003cbr\u003e\nNo. R-407A should never be mixed with other refrigerants. To convert from R-404A, the system must be fully recovered, evacuated, and recharged to maintain the integrity of the zeotropic blend.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the temperature glide of R-407A?\u003c\/strong\u003e\u003cbr\u003e\nR-407A has a temperature glide of approximately 10°F (6°C). It is critical to charge the system using the liquid phase from the cylinder to ensure the correct refrigerant composition enters the system.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":18216055210099,"sku":"R-407A","price":290.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/aaa_64c15475-4a11-4147-bddb-704247e08536.jpg?v=1578593781"},{"product_id":"r-134a","title":"R-134A 30 Lbs Refrigerant HVACR Virgin New Factory Sealed Gas","description":"\u003cp\u003eProfessional-grade \u003cstrong\u003eR-134A 30 lbs refrigerant\u003c\/strong\u003e is the industry standard for medium and high-temperature stationary refrigeration and automotive A\/C systems. This cylinder contains 100% \u003cstrong\u003evirgin R134a gas\u003c\/strong\u003e, ensuring zero cross-contamination and optimal thermal transition in any HFC-ready compressor. Designed as a high-performance replacement for R-12, this \u003cstrong\u003ehydrofluorocarbon (HFC) refrigerant\u003c\/strong\u003e offers a zero-ozone depletion potential and remains the primary choice for standard centrifugal and reciprocating chillers. The tank features a standard \u003cstrong\u003e1\/4\" SAE flare connection\u003c\/strong\u003e, making it ready for field manifolds and recovery equipment. For technicians working on automotive systems, a 1\/2\" ACME adapter is required to interface with standard vehicle charging ports. Whether you are charging a commercial reach-in or performing a complete system evacuation and recharge, this factory-sealed \u003cstrong\u003e30 lb R134a cylinder\u003c\/strong\u003e provides the purity levels necessary to prevent non-condensables from fouling the TXV or capillary tubes. All \u003cstrong\u003ebulk R134a\u003c\/strong\u003e inventory is sourced from established manufacturers to ensure moisture content stays below critical ppm thresholds.\u003c\/p\u003e\n\n\u003ch3\u003eKey Performance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100% Virgin Refrigerant:\u003c\/strong\u003e Ensures maximum ASHRAE efficiency and prevents compressor wear caused by impurities found in reclaimed gases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard HVAC Connection:\u003c\/strong\u003e Features a \u003cstrong\u003e1\/4\" SAE connection\u003c\/strong\u003e for direct compatibility with standard refrigeration gauges and charging hoses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Thermal Stability:\u003c\/strong\u003e Maintains consistent discharge pressures and cooling capacity across a wide range of ambient operating temperatures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Adaptability:\u003c\/strong\u003e Easily converted to \u003cstrong\u003e1\/2\" ACME connection\u003c\/strong\u003e with the AF-13455 adapter for professional automotive AC service.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Sealed Quality:\u003c\/strong\u003e Every cylinder is hermetically sealed to guarantee fluid integrity and full weight upon arrival.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions \u0026amp; Technical Support\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this for automotive air conditioning systems?\u003c\/strong\u003e\u003cbr\u003e\nYes, however, this cylinder uses the \u003cstrong\u003eHVAC standard 1\/4\" SAE flare\u003c\/strong\u003e. To use it with automotive gauges, you must use a specialized adapter to convert the outlet to the 1\/2\" ACME standard found on vehicle systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs an EPA 608 certification required for purchase?\u003c\/strong\u003e\u003cbr\u003e\nYes, federal regulations require an \u003cstrong\u003eEPA 608 license\u003c\/strong\u003e or a valid resale statement to purchase \u003cstrong\u003eR-134a refrigerant\u003c\/strong\u003e. This product is restricted to professional use by certified technicians.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat are the storage requirements for a 30 lb cylinder?\u003c\/strong\u003e\u003cbr\u003e\nKeep the cylinder in a dry, ventilated area. Avoid direct sunlight and ensure the temperature does not exceed 125°F (52°C) to prevent the pressure-relief valve from discharging.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":18216059076723,"sku":"R-134A","price":324.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/R-134A.webp?v=1747249421"},{"product_id":"refrigerant-r-448a-n40-r448a-25-lbs","title":"R-448A (N40) 25 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eStep away from high-GWP HFCs and upgrade your systems with \u003cstrong\u003eR-448A (N40) 25 Lbs Refrigerant\u003c\/strong\u003e. This 100% virgin, factory-sealed gas is the industry-standard \u003cstrong\u003eASHRAE A1 non-flammable\u003c\/strong\u003e HFO blend specifically engineered as a high-performance \u003cstrong\u003eR-404A replacement\u003c\/strong\u003e and \u003cstrong\u003eR-22 retrofit\u003c\/strong\u003e solution. As a veteran-preferred choice for \u003cstrong\u003ecommercial refrigeration\u003c\/strong\u003e, Solstice N40 delivers a 68% reduction in Global Warming Potential (GWP) while maintaining the thermodynamic properties required for low and medium-temperature applications. Reach peak \u003cstrong\u003esystem efficiency\u003c\/strong\u003e with 5-10% better energy performance than R-404A and improved cooling capacity. Designed for \u003cstrong\u003esupermarket rack systems\u003c\/strong\u003e, reach-ins, and cold storage, this zeotropic blend requires \u003cstrong\u003eliquid charging\u003c\/strong\u003e and is fully compatible with synthetic \u003cstrong\u003ePOE oil\u003c\/strong\u003e. Ensure your fleet is equipped with this non-ozone-depleting HFO\/HFC mix to meet modern environmental compliance without sacrificing compressor discharge temperatures or system reliability.\u003c\/p\u003e\n\n\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Retrofit Capability:\u003c\/strong\u003e Seamlessly replaces R-404A, R-507, and R-22 in existing DX systems with minimal component changes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Efficiency:\u003c\/strong\u003e Delivers 5-15% lower energy consumption and up to 7.5% increased capacity compared to legacy refrigerants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower Discharge Temperatures:\u003c\/strong\u003e Reduces stress on compressors in low-temp applications, extending the life of the mechanical assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e Features a GWP of 1273, significantly below the thresholds of the Montreal Protocol and current F-gas regulations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProven Performance:\u003c\/strong\u003e 100% virgin gas manufactured by high-tier producers with decades of refrigeration expertise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat oil must be used with R-448A?\u003c\/strong\u003e This refrigerant is only compatible with synthetic polyolester (POE) lubricants. Existing mineral oil or alkylbenzene must be flushed to acceptable residual levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan I top off an R-404A system with R-448A?\u003c\/strong\u003e No. Mixing refrigerants is never recommended as it alters the pressure-temperature relationship. A full recovery and retrofit are required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIs R-448A flammable?\u003c\/strong\u003e No, it has an ASHRAE A1 safety classification, meaning it is non-flammable and safe for use in commercial supermarket and convenience store environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDoes this require a specific charging method?\u003c\/strong\u003e Yes, because it is a zeotropic blend with temperature glide, it must be charged from the cylinder in the liquid phase to ensure the correct chemical composition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":43069212393650,"sku":"R-448A","price":333.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/asr448a-r-448-a.jpg?v=1755222122"},{"product_id":"refrigerant-r-449a-xp40-r449-25-lbs","title":"R-449A (XP40) 25 Lb Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eThe \u003cstrong\u003eR-449A (XP40) 25 lb Refrigerant\u003c\/strong\u003e is a high-performance HFO-based blend designed as a sustainable, long-term replacement for \u003cstrong\u003eR-404A\u003c\/strong\u003e, \u003cstrong\u003eR-507\u003c\/strong\u003e, and \u003cstrong\u003eR-22\u003c\/strong\u003e in commercial and industrial refrigeration. Engineered for \u003cstrong\u003elow- and medium-temperature applications\u003c\/strong\u003e, including supermarket display cases, walk-in coolers, and cold storage facilities, this \u003cstrong\u003enon-flammable (ASHRAE A1) refrigerant\u003c\/strong\u003e offers an immediate reduction in environmental impact with a \u003cstrong\u003eGWP of 1282\u003c\/strong\u003e. This represents an approximate 67% reduction compared to R-404A. Professionals utilizing \u003cstrong\u003eR-449A 25 lb cylinders\u003c\/strong\u003e benefit from improved energy efficiency, typically ranging from 8% to 12% over legacy HFC systems. As a \u003cstrong\u003ezeotropic blend\u003c\/strong\u003e comprised of R-32, R-125, R-134a, and R-1234yf, it must be charged in the liquid phase to prevent fractionation and ensure optimal system performance. This factory-sealed virgin gas is compatible with existing equipment and \u003cstrong\u003epolyolester (POE) lubricants\u003c\/strong\u003e, making it a reliable choice for retrofitting and new installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits for HVACR Technicians\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Retrofit Compatibility:\u003c\/strong\u003e Functions as a seamless replacement for R-404A and R-507 with minimal equipment modifications required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Energy Efficiency:\u003c\/strong\u003e Delivers up to 12% better energy performance, reducing operational costs for commercial facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Safety Profile:\u003c\/strong\u003e Classified as ASHRAE A1 (non-flammable and low toxicity) for safe handling in high-traffic environments like supermarkets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized Performance:\u003c\/strong\u003e Maintains similar cooling capacity and discharge temperatures to R-404A, ensuring system stability under varying loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Ozone Depletion:\u003c\/strong\u003e Meets stringent environmental regulations, including SNAP and the Kigali Amendment, with 0 ODP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions \u0026amp; Technical Considerations\u003c\/strong\u003e \u003cstrong\u003eIs R-449A a direct drop-in for R-404A?\u003c\/strong\u003e While R-449A is a close performance match, it is a zeotropic blend that requires liquid charging. Technicians should also adjust expansion valves (TXVs) and check superheat settings for optimal efficiency. \u003cstrong\u003eWhat type of oil is required for R-449A?\u003c\/strong\u003e This refrigerant must be used with \u003cstrong\u003epolyolester (POE) oil\u003c\/strong\u003e. If retrofitting from an R-22 system using mineral oil, a full oil flush and transition to POE are mandatory. \u003cstrong\u003eCan I top off an R-404A system with R-449A?\u003c\/strong\u003e No. R-449A should never be mixed with other refrigerants. The existing charge must be recovered properly before charging with R-449A to maintain chemical integrity and system performance.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":44991871385778,"sku":"R-449A","price":368.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/80-180Side__JMRP_v2.jpg?v=1755540782"},{"product_id":"refrigerant-r-452a-xp44-r452a-25-lbs","title":"R-452A (XP44) 25 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eThis 25 lb. cylinder of \u003cstrong\u003eR-452A (XP44) refrigerant\u003c\/strong\u003e provides a high-performance, 100% virgin solution for technicians managing transport refrigeration and commercial cooling systems. Specifically engineered as a \u003cstrong\u003elow Global Warming Potential (GWP) alternative to R-404A\u003c\/strong\u003e and R-507, R-452A features a GWP of approximately 2,140—a 45% reduction compared to legacy HFCs—enabling compliance with evolving environmental mandates without compromising efficiency. As an \u003cstrong\u003eASHRAE A1 non-flammable refrigerant\u003c\/strong\u003e, it offers a safe, low-toxicity profile suitable for direct expansion (DX) applications, including refrigerated trailers, trucks, and supermarket display cases.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eHFO-based refrigerant blend\u003c\/strong\u003e (R-32\/R-125\/R-1234yf) is designed to match the \u003cstrong\u003emass flow and discharge temperatures of R-404A\u003c\/strong\u003e, preserving the life of existing compressors and reducing the risks associated with heat-related stress. It is fully compatible with \u003cstrong\u003ePOE (Polyolester) lubricants\u003c\/strong\u003e, allowing for efficient retrofits with minimal hardware modifications. To maintain the integrity of the zeotropic blend and prevent fractionation, this gas must be charged in the liquid phase from the factory-sealed cylinder.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits for HVACR Professionals:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Engineered to work with existing POE oils and components used in \u003cstrong\u003eR-404A and R-507 systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized Discharge Temperatures:\u003c\/strong\u003e Matches the thermal profile of legacy refrigerants, vital for protecting hermetic and semi-hermetic compressors in low-temp applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit Efficiency:\u003c\/strong\u003e A reliable \u003cstrong\u003eretrofit refrigerant for R-404A\u003c\/strong\u003e that typically requires only minor TXV adjustments rather than major equipment overhauls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e Significantly lower GWP supports adherence to EPA and state-level greenhouse gas reduction targets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Rated:\u003c\/strong\u003e Classified as A1 non-flammable, ensuring standard handling procedures remain applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Questions Regarding R-452A (XP44):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs R-452A a direct drop-in for R-404A?\u003c\/strong\u003e\u003cbr\u003eWhile it provides nearly identical performance, it is considered a \u003cstrong\u003eretrofit solution\u003c\/strong\u003e. Technicians should verify superheat settings after conversion, as minor expansion valve adjustments may be needed to account for the slight temperature glide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat oil should be used with R-452A?\u003c\/strong\u003e\u003cbr\u003eR-452A requires \u003cstrong\u003ePOE lubricant\u003c\/strong\u003e. It is not compatible with mineral oil or alkylbenzene (AB) lubricants often found in older R-502 systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should this refrigerant be charged?\u003c\/strong\u003e\u003cbr\u003eAs a zeotropic blend, \u003cstrong\u003eR-452A must be charged as a liquid\u003c\/strong\u003e. Charging as a vapor will result in fractionation, changing the chemical composition and degrading system performance.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":45162978148530,"sku":"R-452A","price":448.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/80-180Side__JMRP_v2.jpg?v=1755540782"},{"product_id":"r-32-20-lb-refrigerant-virgin-new-factory-sealed-gas-copy","title":"R-32 20 Lb Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eAs a veteran tech, you know the industry is shifting toward lower GWP alternatives. This \u003cstrong\u003eR-32 20 lb refrigerant\u003c\/strong\u003e cylinder contains 100% virgin \u003cstrong\u003edifluoromethane (CH2F2)\u003c\/strong\u003e, providing a high-efficiency solution for \u003cstrong\u003eresidential and commercial air conditioning\u003c\/strong\u003e. With a \u003cstrong\u003eGlobal Warming Potential (GWP) of 675\u003c\/strong\u003e and zero \u003cstrong\u003eOzone Depletion Potential (ODP)\u003c\/strong\u003e, R-32 is the primary replacement for R-410A in modern high-efficiency systems and \u003cstrong\u003eheat pumps\u003c\/strong\u003e. Because R-32 is a \u003cstrong\u003esingle-component refrigerant\u003c\/strong\u003e, it doesn't suffer from glide issues, making it far easier to manage during charging and recovery. Its superior thermodynamic properties allow for an \u003cstrong\u003eoptimized heat transfer\u003c\/strong\u003e and a \u003cstrong\u003ereduced refrigerant charge\u003c\/strong\u003e—requiring up to 30% less volume than R-410A for the same cooling capacity. This \u003cstrong\u003efactory sealed gas\u003c\/strong\u003e is classified as \u003cstrong\u003eASHRAE A2L\u003c\/strong\u003e (mildly flammable), requiring proper handling and tools compliant with mildly flammable refrigerants. Sourced from manufacturers with 30+ years of proven quality, this \u003cstrong\u003evirgin R-32 gas\u003c\/strong\u003e ensures system stability and maximum performance for \u003cstrong\u003eVRF\/VRB systems\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Energy Efficiency:\u003c\/strong\u003e Delivers superior cooling and heating performance while reducing overall power consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e Meets modern environmental standards under the Kigali Amendment by reducing GWP by nearly 70% compared to R-410A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePure Composition:\u003c\/strong\u003e As a 100% \u003cstrong\u003epure refrigerant\u003c\/strong\u003e, it is significantly easier to recycle and reuse compared to blended hydrofluorocarbons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower Operating Costs:\u003c\/strong\u003e High heat transfer coefficients lead to improved system efficiency and longevity for the compressor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e Engineered for use in the latest HVAC units designed for \u003cstrong\u003elow GWP HVAC refrigerant\u003c\/strong\u003e standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use R-32 in an existing R-410A system?\u003c\/strong\u003e\u003cbr\u003e\nNo. While they share similar pressure characteristics, R-32 is an \u003cstrong\u003eA2L mildly flammable refrigerant\u003c\/strong\u003e. Systems must be specifically designed with the proper safety controls, sensors, and compatible lubricants to handle R-32. Retofitting R-410A equipment to R-32 is not permitted.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs R-32 difficult to charge or recover?\u003c\/strong\u003e\u003cbr\u003e\nActually, it’s easier. Since it is not a blend, there is no temperature glide to worry about. You can charge it in either liquid or gas phases without risking composition changes, and it is highly efficient to recover and reclaim.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat safety precautions are needed for A2L refrigerants?\u003c\/strong\u003e\u003cbr\u003e\nTechnicians must use \u003cstrong\u003eA2L-certified manifold gauges\u003c\/strong\u003e, vacuum pumps, and recovery machines. Ensure adequate ventilation and eliminate potential ignition sources during the service process as per standard HVACR safety protocols.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":46074410467506,"sku":"R-32","price":192.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/80-180Side__JMRP_v2_72814f37-3c53-46f9-9969-aec0350ee7d8.jpg?v=1755713950"},{"product_id":"ez-flush-22-lb-virgin-new-factory-sealed-gas","title":"EZ Flush 22 Lb Virgin New Factory Sealed Gas","description":"\u003cp\u003eEnsure a clean system and optimal heat transfer with \u003cstrong\u003eEZ Flush 22 Lb Virgin HVAC Flushing Agent\u003c\/strong\u003e. This professional-grade \u003cstrong\u003erefrigerant line flush\u003c\/strong\u003e is engineered for technicians who need a reliable solution to remove residual mineral oils, POE oils, moisture, and acid during critical \u003cstrong\u003eHVAC system retrofits\u003c\/strong\u003e. Unlike standard solvents, this \u003cstrong\u003elow-GWP flushing solvent\u003c\/strong\u003e features a high evaporation rate, ensuring that no residue remains in the lines to contaminate new refrigerant charges. Whether you are performing a \u003cstrong\u003erefrigerant conversion\u003c\/strong\u003e from R-22 to R-410A or cleaning a system after a compressor burnout, this 100% virgin formula provides the solvency necessary to strip internal contaminants without damaging system components. Designed for universal compatibility, it is an essential tool for maintaining the efficiency of residential and commercial air conditioning and refrigeration systems.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits for Technicians\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSuperior Oil Solvency:\u003c\/strong\u003e Effectively breaks down and flushes out old mineral, alkylbenzene, and polyolester (POE) oils.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNon-Ozone Depleting Formula:\u003c\/strong\u003e Environmentally responsible chemistry that meets modern regulatory standards for \u003cstrong\u003enon-flammable HVAC cleaners\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFast Evaporation:\u003c\/strong\u003e Minimizes downtime by quickly drying within the lines, allowing for faster evacuation and charging.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUniversal Compatibility:\u003c\/strong\u003e Safe for use in systems utilizing R-22, R-410A, R-134a, R-404A, and R-1234yf.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompressor Protection:\u003c\/strong\u003e Removes acidic buildup and particulates that can cause premature mechanical failure after a system \u003cstrong\u003erefrigerant changeover\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use EZ Flush without a nitrogen purge?\u003c\/strong\u003e\u003cbr\u003e\nFor best results and to ensure all loosened contaminants are fully removed from the circuit, we recommend following the flush with a high-pressure nitrogen purge through the liquid and suction lines.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs EZ Flush safe for use with all expansion valves?\u003c\/strong\u003e\u003cbr\u003e\nWhile the solvent is compatible with most materials, it is standard trade practice to bypass or remove TXVs, solenoids, and filter driers prior to the flushing process to prevent clogging and ensure the most thorough cleaning of the heat exchangers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this product require an EPA 608 certification?\u003c\/strong\u003e\u003cbr\u003e\nYes, an \u003cstrong\u003eEPA 608 License\u003c\/strong\u003e or a Resale Statement is required to purchase this industrial-grade flushing agent.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":46133351973042,"sku":"EZ-Flush","price":437.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/80-180Side__JMRP_v2_72814f37-3c53-46f9-9969-aec0350ee7d8.jpg?v=1755713950"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/collections\/Pic_ddd3aa8a-c7a2-4983-ab61-48dedbfa567e.png?v=1743446291","url":"https:\/\/www.gsistore.com\/en-ca\/collections\/refrigerant\/els-pw-5628-35648479116.oembed","provider":"GSIstore","version":"1.0","type":"link"}