{"product_id":"burnham-boiler-104704-01","title":"Burnham Boiler 104704-01 Condensate Trap","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham Boiler 104704-01 Condensate Trap Kit\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e replacement \u003cstrong\u003econdensate trap\u003c\/strong\u003e for \u003cstrong\u003eAlpine\u003c\/strong\u003e condensing boilers from the \u003cstrong\u003eALP080B\u003c\/strong\u003e through the \u003cstrong\u003eALP285B\u003c\/strong\u003e. Burnham describes the kit as the trap, a \u003cstrong\u003efloat switch\u003c\/strong\u003e, a \u003cstrong\u003egrommet\u003c\/strong\u003e, a \u003cstrong\u003ecoupling\u003c\/strong\u003e and \u003cstrong\u003eclamps\u003c\/strong\u003e, and the kit is supplied with white \u003cstrong\u003etrap tubing\u003c\/strong\u003e, a black \u003cstrong\u003erubber grommet\u003c\/strong\u003e, a white \u003cstrong\u003ecoupling\u003c\/strong\u003e and a tube of \u003cstrong\u003eRTV silicone sealant\u003c\/strong\u003e for the joints. A condensing boiler pulls so much heat from the exhaust that water vapor condenses in the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e and \u003cstrong\u003eflue\u003c\/strong\u003e, and the trap is where that \u003cstrong\u003econdensate\u003c\/strong\u003e is collected and drained without letting \u003cstrong\u003eflue gas\u003c\/strong\u003e escape into the room.\u003c\/p\u003e\n\n\u003cp\u003eThe trap's \u003cstrong\u003efloat switch\u003c\/strong\u003e is a safety device: if the drain clogs and the \u003cstrong\u003econdensate\u003c\/strong\u003e level climbs, the switch tells the control to stop firing before water backs up into the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e. Condensate is acidic and carries sediment, so a trap can foul, crack or leak at the joints over the years. A clogged trap gives a \u003cstrong\u003econdensate fault\u003c\/strong\u003e or a lockout, a leaking trap puts water on the floor under the boiler, and a worn \u003cstrong\u003egrommet\u003c\/strong\u003e or hose can let \u003cstrong\u003eflue gas\u003c\/strong\u003e by. Burnham's parts list for the \u003cstrong\u003eALP080B\u003c\/strong\u003e, \u003cstrong\u003eALP105B\u003c\/strong\u003e, \u003cstrong\u003eALP150B\u003c\/strong\u003e, \u003cstrong\u003eALP210B\u003c\/strong\u003e and \u003cstrong\u003eALP285B\u003c\/strong\u003e boilers places the trap kit \u003cstrong\u003e104704-01\u003c\/strong\u003e beside the \u003cstrong\u003efloat switch\u003c\/strong\u003e kit \u003cstrong\u003e105005-01\u003c\/strong\u003e, the \u003cstrong\u003espring clip\u003c\/strong\u003e \u003cstrong\u003e101632-01\u003c\/strong\u003e (two per boiler) and the \u003cstrong\u003erubber grommet\u003c\/strong\u003e \u003cstrong\u003e101595-01\u003c\/strong\u003e, which are the parts to have on hand at the same visit. The \u003cstrong\u003econdensate neutralizer kit\u003c\/strong\u003e \u003cstrong\u003e101867-01\u003c\/strong\u003e and the \u003cstrong\u003elimestone chips\u003c\/strong\u003e \u003cstrong\u003e101873-01\u003c\/strong\u003e belong to the same drain system and treat the acidity before disposal.\u003c\/p\u003e\n\n\u003cp\u003eTo replace the trap, switch off the power, let the boiler cool, and release the drain hose and the trap from the heat exchanger connection. Rinse out any sediment, assemble the new \u003cstrong\u003etrap tubing\u003c\/strong\u003e with the \u003cstrong\u003ecoupling\u003c\/strong\u003e, \u003cstrong\u003egrommet\u003c\/strong\u003e and \u003cstrong\u003eclamps\u003c\/strong\u003e, apply the \u003cstrong\u003eRTV silicone sealant\u003c\/strong\u003e where the joints call for it and wait for it to cure as the sealant directions state. Refill the trap with water before the first firing, restore power and run the boiler while you watch every joint for leaks and verify the \u003cstrong\u003efloat switch\u003c\/strong\u003e is connected. Confirm the boiler model on the rating plate against the \u003cstrong\u003eAlpine\u003c\/strong\u003e sizes above, and check local code for \u003cstrong\u003econdensate\u003c\/strong\u003e disposal.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eComplete Trap Kit:\u003c\/strong\u003e Includes the \u003cstrong\u003econdensate trap\u003c\/strong\u003e tubing, \u003cstrong\u003efloat switch\u003c\/strong\u003e, \u003cstrong\u003egrommet\u003c\/strong\u003e, \u003cstrong\u003ecoupling\u003c\/strong\u003e and \u003cstrong\u003eclamps\u003c\/strong\u003e with \u003cstrong\u003eRTV silicone sealant\u003c\/strong\u003e for the joints.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAlpine ALP080B To ALP285B:\u003c\/strong\u003e Burnham's parts list shows the \u003cstrong\u003e104704-01\u003c\/strong\u003e on the \u003cstrong\u003eALP080B\u003c\/strong\u003e, \u003cstrong\u003eALP105B\u003c\/strong\u003e, \u003cstrong\u003eALP150B\u003c\/strong\u003e, \u003cstrong\u003eALP210B\u003c\/strong\u003e and \u003cstrong\u003eALP285B\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety Float Switch:\u003c\/strong\u003e The \u003cstrong\u003efloat switch\u003c\/strong\u003e stops the burner before a blocked drain lets \u003cstrong\u003econdensate\u003c\/strong\u003e back up into the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStops Condensate Leaks:\u003c\/strong\u003e A fresh trap and \u003cstrong\u003egrommet\u003c\/strong\u003e end drips, \u003cstrong\u003econdensate faults\u003c\/strong\u003e and \u003cstrong\u003eflue gas\u003c\/strong\u003e bypass at old joints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhich Alpine boilers use this trap kit?\u003c\/strong\u003e Burnham's parts list covers the \u003cstrong\u003eALP080B\u003c\/strong\u003e, \u003cstrong\u003eALP105B\u003c\/strong\u003e, \u003cstrong\u003eALP150B\u003c\/strong\u003e, \u003cstrong\u003eALP210B\u003c\/strong\u003e and \u003cstrong\u003eALP285B\u003c\/strong\u003e. Confirm the boiler model on the rating plate.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat else should I replace with the trap?\u003c\/strong\u003e The \u003cstrong\u003efloat switch\u003c\/strong\u003e kit \u003cstrong\u003e105005-01\u003c\/strong\u003e, \u003cstrong\u003espring clips\u003c\/strong\u003e \u003cstrong\u003e101632-01\u003c\/strong\u003e and \u003cstrong\u003egrommet\u003c\/strong\u003e \u003cstrong\u003e101595-01\u003c\/strong\u003e are the related parts, and the \u003cstrong\u003eneutralizer kit\u003c\/strong\u003e is \u003cstrong\u003e101867-01\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo I refill the trap?\u003c\/strong\u003e Yes. Fill the trap with water before the first firing so \u003cstrong\u003eflue gas\u003c\/strong\u003e cannot pass through the drain.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68120327585970,"sku":"104704-01","price":177.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/104704-01.jpg?v=1795308267","url":"https:\/\/www.gsistore.com\/en-ca\/products\/burnham-boiler-104704-01","provider":"GSIstore","version":"1.0","type":"link"}