{"product_id":"hankison-hprb7-a-air-dryer","title":"Hankison HPRB7-A Air Dryer","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eSPX Flow-Hankison HPRB7-A refrigerated air dryer\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e is designed to remove moisture from compressed-air systems with airflow requirements up to \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e7 SCFM\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. Operating on a \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e115V single-phase electrical supply\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e, this compact dryer is suited for appropriately sized air compressors serving workshops, maintenance facilities, pneumatic equipment, and industrial compressed-air applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eHankison HPRB7-A compressed air dryer\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e uses refrigeration to cool incoming compressed air, allowing water vapor to condense and separate from the air stream. Removing condensed moisture helps reduce water accumulation in downstream piping, air tools, regulators, and pneumatic components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAs a \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003erefrigerated compressed air dryer\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e, it is intended for applications requiring controlled moisture removal rather than the extremely low dew points associated with desiccant dryers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen selecting this \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e7 SCFM air compressor dryer\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e, technicians should verify compressor output, operating pressure, inlet-air temperature, ambient conditions, electrical requirements, and piping connections. Actual drying capacity depends on the installation conditions. Proper sizing and condensate drainage are essential for dependable compressed-air system operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e SPX Flow – Hankison\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e HPRB7-A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Refrigerated compressed-air dryer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDryer Operation:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Non-cycling refrigerated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAirflow Capacity:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 7 SCFM nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Supply:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 115V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhase:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Single-phase\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Approximately 0.15 kW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e R513A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRated Pressure Dew Point:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 50°F (10°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAir Inlet and Outlet:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 3\/8-inch male NPT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inlet Air Pressure:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 200 PSIG\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inlet Air Temperature:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 120°F (48°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Operating Temperature:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 40°F to 110°F (4°C to 43°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 12.6 inches wide × 12.6 inches deep × 15.3 inches high\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Approximately 45 lb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondensate Drain:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Pneumatic float drain\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRated Flow Conditions:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e 100 PSIG inlet pressure, 100°F inlet air temperature, and 100°F ambient temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDrying Technology:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Refrigeration-based moisture removal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMoisture Management:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Condenses and separates water vapor from compressed air\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Protection:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Helps reduce liquid-water carryover into downstream pneumatic equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Application:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Suitable for appropriately sized compressed-air installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEquipment Compatibility:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Verify compressor capacity, operating pressure, connection sizes, and inlet conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Provide appropriate ventilation, condensate drainage, and electrical connections according to manufacturer instructions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What size air compressor can be used with the Hankison HPRB7-A?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The HPRB7-A has a nominal airflow rating of \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e7 SCFM\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e. The compressor's actual delivered airflow must be evaluated against the dryer's capacity at the intended inlet temperature, operating pressure, and ambient conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA compressor's horsepower rating alone is not sufficient for sizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How does the SPX Flow-Hankison HPRB7-A remove moisture from compressed air?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The dryer cools compressed air through a refrigeration circuit, causing water vapor to condense. The condensed moisture is then separated and discharged through the condensate drainage system. This reduces liquid-water carryover into downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the Hankison HPRB7-A suitable for applications requiring extremely dry compressed air?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The HPRB7-A is a refrigerated air dryer intended for general compressed-air moisture control, with a rated pressure dew point of approximately \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e50°F (10°C)\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplications requiring substantially lower pressure dew points, such as certain instrumentation or specialized industrial processes, may require desiccant drying equipment instead.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eDisclaimer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhile we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPRB7-A is the cross for HPR5-10\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/span\u003e\u003cspan style=\"font-size: 10.0pt; font-family: 'Arial',sans-serif; color: red; background: white;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e","brand":"Hankison","offers":[{"title":"Default Title","offer_id":35657357772,"sku":"HPRB7-A","price":1938.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_c9f582b8-d676-4de0-9115-a1809aac87ed.webp?v=1794864615","url":"https:\/\/www.gsistore.com\/en-ca\/products\/hankison-hprb7-a-air-dryer","provider":"GSIstore","version":"1.0","type":"link"}