{"product_id":"icm-controls-icm104-relay","title":"ICM Controls ICM104 Relay","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eICM Controls ICM104 Delay-On-Make Timer\u003c\/strong\u003e is an adjustable HVAC\/R time-delay relay designed for applications requiring controlled equipment startup. Operating at \u003cstrong\u003e18–30 VAC, 50\/60 Hz\u003c\/strong\u003e, the ICM104 provides an adjustable \u003cstrong\u003e10–1,000 second time delay\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhen input power is applied, the timing cycle begins. Once the selected delay expires, the load energizes. The control uses precise digital circuitry with an isolated, high-power \u003cstrong\u003eSPDT (1 Form C) relay output\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe normally open contact is rated at \u003cstrong\u003e20 amps at 240 VAC\u003c\/strong\u003e, while the normally closed contact is rated at \u003cstrong\u003e10 amps at 240 VAC\u003c\/strong\u003e. Motor load ratings are \u003cstrong\u003e2 HP N.O. and 1\/2 HP N.C. at 120\/240 VAC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe ICM104 is suitable for HVAC\/R equipment and other electrical applications where delayed or staggered equipment startup is required.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eICM104 Delay-On-Make Timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAdjustable \u003cstrong\u003e10–1,000 second\u003c\/strong\u003e delay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18–30 VAC, 50\/60 Hz\u003c\/strong\u003e input\u003c\/li\u003e\n\u003cli\u003eHigh-power \u003cstrong\u003eSPDT (1 Form C) relay output\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eN.O. contact rating: \u003cstrong\u003e20A at 240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eN.C. contact rating: \u003cstrong\u003e10A at 240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMotor rating: \u003cstrong\u003e2 HP N.O. at 120\/240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMotor rating: \u003cstrong\u003e1\/2 HP N.C. at 120\/240 VAC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput-to-output isolation\u003c\/li\u003e\n\u003cli\u003eCompatible with anticipator-type thermostats\u003c\/li\u003e\n\u003cli\u003eDesigned for delayed or staggered equipment startup\u003c\/li\u003e\n\u003cli\u003eManufacturer-listed replacement for select MARS time-delay controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the ICM104 do?\u003c\/strong\u003e\u003cbr\u003eThe ICM104 delays equipment startup after input power is applied. Once the selected delay period expires, the relay energizes the connected load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the adjustable time range?\u003c\/strong\u003e\u003cbr\u003eThe ICM104 can be adjusted from \u003cstrong\u003e10 to 1,000 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does the ICM104 require?\u003c\/strong\u003e\u003cbr\u003eThe control operates on \u003cstrong\u003e18–30 VAC at 50\/60 Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ICM104 have an SPDT output?\u003c\/strong\u003e\u003cbr\u003eYes. It uses a high-power \u003cstrong\u003eSPDT (1 Form C) relay\u003c\/strong\u003e with normally open and normally closed contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ICM104 be used for staggered equipment startup?\u003c\/strong\u003e\u003cbr\u003eYes. It is suitable for applications requiring delayed or staggered startup. Always verify the control voltage, contact load, wiring configuration, and required timing before installation.\u003c\/p\u003e\n\u003ch3\u003eSEO Keywords\u003c\/h3\u003e\n\u003cp\u003eICM104 delay on make timer, HVAC time delay relay, adjustable time delay relay, 24V time delay relay, ICM Controls time delay\u003c\/p\u003e\n\u003ch3\u003eCommon Search Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat does an ICM104 delay-on-make timer do?\u003c\/li\u003e\n\u003cli\u003eHow do I adjust an ICM104 time delay?\u003c\/li\u003e\n\u003cli\u003eWhat are the voltage and contact ratings for the ICM104?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"ICM Controls","offers":[{"title":"Default Title","offer_id":47886109868210,"sku":"ICM104","price":64.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/Image_79faa24e-33f1-435a-85ab-a886ebc82158.png?v=1786567910","url":"https:\/\/www.gsistore.com\/en-ca\/products\/icm-controls-icm104-relay","provider":"GSIstore","version":"1.0","type":"link"}