{"product_id":"lennox-16k07-repair-coil-assembly","title":"Lennox 16K07 Coil Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eLennox 16K07 Repair Coil Assembly\u003c\/strong\u003e is the factory replacement \u003cstrong\u003eevaporator coil\u003c\/strong\u003e for the \u003cstrong\u003eLennox CBA25UH\u003c\/strong\u003e and \u003cstrong\u003eCBA25UHV\u003c\/strong\u003e upflow\/horizontal \u003cstrong\u003eair handlers\u003c\/strong\u003e in the \u003cstrong\u003eCBA25UH\/V-060\u003c\/strong\u003e size. Reading the Lennox model number, \u003cstrong\u003eCB\u003c\/strong\u003e is the air handler, \u003cstrong\u003eA\u003c\/strong\u003e is the \u003cstrong\u003ealuminum coil\u003c\/strong\u003e on \u003cstrong\u003eR-410A\u003c\/strong\u003e, and \u003cstrong\u003e060\u003c\/strong\u003e is the nominal \u003cstrong\u003e5 ton\u003c\/strong\u003e size. The \u003cstrong\u003e16K07\u003c\/strong\u003e catalog number is also listed under manufacturer number \u003cstrong\u003e618394-07\u003c\/strong\u003e, so keep both numbers handy when searching older parts records or an existing coil's paperwork.\u003c\/p\u003e\n\n\u003cp\u003eThe coil in this series is Lennox's own \u003cstrong\u003eQuantum coil\u003c\/strong\u003e, built from \u003cstrong\u003eenhanced aluminum alloy tube\u003c\/strong\u003e and an \u003cstrong\u003eenhanced fin\u003c\/strong\u003e surface. On the \u003cstrong\u003e048\u003c\/strong\u003e and \u003cstrong\u003e060\u003c\/strong\u003e sizes it is a \u003cstrong\u003etwin coil\u003c\/strong\u003e assembled in an \u003cstrong\u003e\"A\" configuration\u003c\/strong\u003e, which puts a lot of surface area in a compact cabinet while keeping \u003cstrong\u003eair resistance\u003c\/strong\u003e low. The refrigerant connections are \u003cstrong\u003ecopper sweat fittings\u003c\/strong\u003e on both the \u003cstrong\u003eliquid line\u003c\/strong\u003e and \u003cstrong\u003esuction line\u003c\/strong\u003e for brazing, and the series is designed for \u003cstrong\u003eR-410A\u003c\/strong\u003e systems that meter refrigerant with an \u003cstrong\u003eexpansion valve (TXV)\u003c\/strong\u003e, on both \u003cstrong\u003eair conditioner\u003c\/strong\u003e and \u003cstrong\u003eheat pump\u003c\/strong\u003e matches. Every \u003cstrong\u003eCBA25UH\u003c\/strong\u003e size has its own repair coil: \u003cstrong\u003e16K01\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-018\u003c\/strong\u003e, \u003cstrong\u003e16K02\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-024\u003c\/strong\u003e, \u003cstrong\u003e16K03\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-030\u003c\/strong\u003e, \u003cstrong\u003e16K04\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-036\u003c\/strong\u003e, \u003cstrong\u003e16K05\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-042\u003c\/strong\u003e and \u003cstrong\u003e16K06\u003c\/strong\u003e for the \u003cstrong\u003eCBA25UH\/V-048\u003c\/strong\u003e. Those are separate parts and will not substitute for the \u003cstrong\u003e16K07\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eBefore condemning a coil, confirm the leak. A low-charge system with \u003cstrong\u003eoil staining\u003c\/strong\u003e at the \u003cstrong\u003etube joints\u003c\/strong\u003e or \u003cstrong\u003ehairpin bends\u003c\/strong\u003e usually points to the coil, but verify it with \u003cstrong\u003enitrogen\u003c\/strong\u003e pressure, \u003cstrong\u003ebubble solution\u003c\/strong\u003e and an \u003cstrong\u003eelectronic leak detector\u003c\/strong\u003e, and rule out a frozen coil caused by a dirty \u003cstrong\u003eair filter\u003c\/strong\u003e, weak \u003cstrong\u003eblower\u003c\/strong\u003e airflow or a plugged \u003cstrong\u003econdensate drain\u003c\/strong\u003e. When the replacement goes in, recover the refrigerant, flow \u003cstrong\u003edry nitrogen\u003c\/strong\u003e while brazing, shield the \u003cstrong\u003eexpansion valve\u003c\/strong\u003e and cabinet from heat, and install a new \u003cstrong\u003efilter drier\u003c\/strong\u003e. Pressure test, pull a deep \u003cstrong\u003evacuum\u003c\/strong\u003e, then weigh in the charge with a scale to the outdoor unit's data plate. Reseat the \u003cstrong\u003edrain pan\u003c\/strong\u003e, \u003cstrong\u003edrip shields\u003c\/strong\u003e and \u003cstrong\u003eseal plates\u003c\/strong\u003e so condensate drains cleanly and no air bypasses the coil.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExact-Size Match:\u003c\/strong\u003e Built for the \u003cstrong\u003eCBA25UH\/V-060\u003c\/strong\u003e \u003cstrong\u003e5 ton\u003c\/strong\u003e air handler, so the coil geometry and \u003cstrong\u003erefrigerant connections\u003c\/strong\u003e line up with the original.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Quantum Coil Design:\u003c\/strong\u003e \u003cstrong\u003eEnhanced aluminum alloy tube\u003c\/strong\u003e and \u003cstrong\u003eenhanced fin\u003c\/strong\u003e construction in the twin \u003cstrong\u003e\"A\" configuration\u003c\/strong\u003e used by Lennox on the \u003cstrong\u003e060\u003c\/strong\u003e size.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBrazed Copper Connections:\u003c\/strong\u003e \u003cstrong\u003eSweat fittings\u003c\/strong\u003e on the \u003cstrong\u003eliquid\u003c\/strong\u003e and \u003cstrong\u003esuction\u003c\/strong\u003e lines make for a standard \u003cstrong\u003eR-410A\u003c\/strong\u003e field installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEasy Cross-Reference:\u003c\/strong\u003e Catalog number \u003cstrong\u003e16K07\u003c\/strong\u003e and manufacturer number \u003cstrong\u003e618394-07\u003c\/strong\u003e let you match the part to Lennox records and service literature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the Lennox 16K07 used for?\u003c\/strong\u003e It replaces a leaking or damaged \u003cstrong\u003eevaporator coil\u003c\/strong\u003e in a \u003cstrong\u003eCBA25UH\/V-060\u003c\/strong\u003e \u003cstrong\u003e5 ton\u003c\/strong\u003e air handler.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWill the 16K07 fit every CBA25UH air handler?\u003c\/strong\u003e No. Each size has its own repair coil, from \u003cstrong\u003e16K01\u003c\/strong\u003e through \u003cstrong\u003e16K06\u003c\/strong\u003e for the smaller sizes, so confirm the full \u003cstrong\u003emodel number\u003c\/strong\u003e and \u003cstrong\u003eserial number\u003c\/strong\u003e on the data plate before ordering.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is the manufacturer number for the 16K07?\u003c\/strong\u003e The associated number is \u003cstrong\u003e618394-07\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin-top: 0in;\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: 'Segoe UI',sans-serif; color: #ff2a00;\"\u003eThis item is not eligible for free shipping and must be shipped via trucking. Please contact us for a freight quote.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Segoe UI',sans-serif; color: #1f2124;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Lennox","offers":[{"title":"Default Title","offer_id":67695179694258,"sku":"16K07","price":1356.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_d99c11aa-b49b-4750-ab4d-37a14754acd5.webp?v=1791920924","url":"https:\/\/www.gsistore.com\/en-ca\/products\/lennox-16k07-repair-coil-assembly","provider":"GSIstore","version":"1.0","type":"link"}