{"product_id":"r-404a-24-lbs-refrigerant-virgin-new-factory-sealed-gas","title":"R-404A 24 Lbs Refrigerant Virgin New Factory Sealed Gas","description":"\u003cp\u003eThis 24 lb. cylinder contains factory-sealed, \u003cstrong\u003e100% virgin R-404A refrigerant\u003c\/strong\u003e, a zeotropic HFC blend of 44% R-125, 52% R-143a, and 4% R-134a widely used in commercial and industrial refrigeration. Unlike near-azeotropic blends, \u003cstrong\u003eR-404A gas\u003c\/strong\u003e exhibits a measurable temperature glide, so it must always be charged into a system as a liquid to preserve the correct component ratio and prevent fractionation. Originally developed as a drop-in replacement for \u003cstrong\u003eR-502 and low-temperature R-22 systems\u003c\/strong\u003e, this \u003cstrong\u003enon-ozone depleting refrigerant\u003c\/strong\u003e requires \u003cstrong\u003ePOE (Polyolester) lubricant\u003c\/strong\u003e for proper oil return in compressors. Marketed under names such as \u003cstrong\u003eGenetron 404A, Suva HP62, and Forane 404A\u003c\/strong\u003e, it carries an ASHRAE A1 safety classification, confirming low toxicity and no flame propagation. When performing a \u003cstrong\u003erefrigerant recharge\u003c\/strong\u003e on supermarket display cases, walk-in freezers, or transport refrigeration units, utilizing \u003cstrong\u003evirgin R-404A\u003c\/strong\u003e ensures the absence of contaminants or moisture that compromise suction pressure and superheat readings. Ensure all recovery and manifold equipment is rated for the 3.73 MPa critical pressure of this \u003cstrong\u003emedium- and low-temperature refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits for Technicians:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Low-Temperature Capacity:\u003c\/strong\u003e Formulated for stable performance across medium- and low-temperature commercial refrigeration ranges, including freezers and cold storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Longevity:\u003c\/strong\u003e Using \u003cstrong\u003evirgin R-404A 24 lbs\u003c\/strong\u003e cylinders prevents the introduction of moisture or mixed gases often found in low-quality reclaimed batches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Ozone Depleting:\u003c\/strong\u003e Contains no chlorine, making it a compliant HFC alternative to legacy \u003cstrong\u003eR-502 and R-22\u003c\/strong\u003e refrigeration systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Phase Charging Accuracy:\u003c\/strong\u003e Zeotropic composition requires liquid charging, allowing technicians to maintain the precise 44\/52\/4 blend ratio for consistent capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Contractor Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan R-404A be used to retrofit an existing R-502 or low-temp R-22 system?\u003c\/strong\u003e\u003cbr\u003eYes, with modifications. \u003cstrong\u003eR-404A refrigerant\u003c\/strong\u003e was designed as a common retrofit for R-502 and low-temperature R-22 refrigeration equipment, but the compressor oil must be changed to \u003cstrong\u003ePOE oil\u003c\/strong\u003e, and expansion devices may need adjustment for the different pressure and glide characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an EPA certification required for purchase?\u003c\/strong\u003e\u003cbr\u003eYes. To purchase \u003cstrong\u003ewholesale R-404A refrigerant\u003c\/strong\u003e, you must provide a valid EPA refrigerant handling certification or a Resale Statement in accordance with federal law. This product is restricted to the Lower 48 states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must R-404A always be removed from the cylinder as a liquid?\u003c\/strong\u003e\u003cbr\u003eBecause R-404A is a \u003cstrong\u003ezeotropic blend\u003c\/strong\u003e with a notable temperature glide, removing it as vapor would cause fractionation, altering the 44% R-125 \/ 52% R-143a \/ 4% R-134a ratio and reducing system performance. Liquid-phase transfer keeps the blend intact.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #ff0000;\"\u003eEPA 608 License or Resale Statement Required to Purchase. Available to Lower 48 only.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Refrigerant","offers":[{"title":"Default Title","offer_id":48069736202418,"sku":null,"price":375.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/r404a_refrigerant_pure_white_bg.png?v=1789757593","url":"https:\/\/www.gsistore.com\/en-ca\/products\/r-404a-24-lbs-refrigerant-virgin-new-factory-sealed-gas","provider":"GSIstore","version":"1.0","type":"link"}