{"product_id":"trane-kit16529","title":"Trane KIT16529 Power Pack","description":"\u003cp\u003eThe \u003cstrong\u003eTrane KIT16529\u003c\/strong\u003e is the \u003cstrong\u003ecomplete communicating power pack door assembly\u003c\/strong\u003e for the \u003cstrong\u003eAmerican Standard AccuClean\u003c\/strong\u003e and \u003cstrong\u003eTrane CleanEffects\u003c\/strong\u003e \u003cstrong\u003ewhole-house electronic air cleaners\u003c\/strong\u003e. Trane's own service bulletin \u003cstrong\u003eACC-SVB19D-EN\u003c\/strong\u003e lists \u003cstrong\u003eKIT16529\u003c\/strong\u003e as the new door kit for the \u003cstrong\u003eAFD245CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eAFD245CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eAFD24DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eAFD24DCLFR000D\u003c\/strong\u003e air cleaners. The door is the heart of the unit: it houses the internal \u003cstrong\u003econtrol board\u003c\/strong\u003e and \u003cstrong\u003epower pack\u003c\/strong\u003e that energize the \u003cstrong\u003efield charger\u003c\/strong\u003e and the \u003cstrong\u003ecollection cells\u003c\/strong\u003e, and on a \u003cstrong\u003ecommunicating system\u003c\/strong\u003e it is also the \u003cstrong\u003ecommunication link\u003c\/strong\u003e that lets the air cleaner talk to the \u003cstrong\u003eTrane comfort control\u003c\/strong\u003e. Trane rates the \u003cstrong\u003eCleanEffects\u003c\/strong\u003e system to remove up to \u003cstrong\u003e99.98 percent\u003c\/strong\u003e of airborne allergens down to \u003cstrong\u003e0.1 micron\u003c\/strong\u003e, and none of that happens when the door stops powering the charger and cells.\u003c\/p\u003e\n\n\u003cp\u003eTrane issued \u003cstrong\u003eACC-SVB19D-EN\u003c\/strong\u003e (December 2, 2013) for \u003cstrong\u003eAccuClean\u003c\/strong\u003e and \u003cstrong\u003eCleanEffects\u003c\/strong\u003e air cleaners that \u003cstrong\u003egenerate communicating errors\u003c\/strong\u003e when installed in \u003cstrong\u003ecommunicating mode\u003c\/strong\u003e. Affected units can throw \u003cstrong\u003eerror codes\u003c\/strong\u003e at the comfort control with a potential \u003cstrong\u003eloss of heating or cooling operation\u003c\/strong\u003e, and the bulletin covers units with \u003cstrong\u003eserial numbers prior to 1309XXXXXX\u003c\/strong\u003e. It is a \u003cstrong\u003efix-on-fail\u003c\/strong\u003e action, not a safety action. On a system with a \u003cstrong\u003esingle air cleaner\u003c\/strong\u003e, Trane's fix is to replace only the internal \u003cstrong\u003econtrol board CNT06888\u003c\/strong\u003e per installation guide \u003cstrong\u003e18-HE94D1-1\u003c\/strong\u003e. On systems with \u003cstrong\u003emultiple air cleaners\u003c\/strong\u003e, Trane recommends replacing the \u003cstrong\u003eentire door assembly\u003c\/strong\u003e, and that is exactly what \u003cstrong\u003eKIT16529\u003c\/strong\u003e is.\u003c\/p\u003e\n\n\u003cp\u003eMatch the kit to the model number on the air cleaner nameplate, because each size has its own door. The same bulletin pairs \u003cstrong\u003eAFD145CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eAFD145CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eAFD14DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eAFD14DCLFR000D\u003c\/strong\u003e with \u003cstrong\u003eKIT16524\u003c\/strong\u003e; \u003cstrong\u003eAFD175CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eAFD175CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eAFD17DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eAFD17DCLFR000D\u003c\/strong\u003e with \u003cstrong\u003eKIT16525\u003c\/strong\u003e; and \u003cstrong\u003eAFD210CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eAFD210CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eAFD21DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eAFD21DCLFR000D\u003c\/strong\u003e with \u003cstrong\u003eKIT16526\u003c\/strong\u003e. The Trane-branded \u003cstrong\u003eTFD245CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eTFD245CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eTFD24DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eTFD24DCLFR000D\u003c\/strong\u003e units take \u003cstrong\u003eKIT16536\u003c\/strong\u003e instead.\u003c\/p\u003e\n\n\u003cp\u003eInstallation is straightforward once you respect the high-voltage section. With power off, \u003cstrong\u003eunplug the power cable\u003c\/strong\u003e from the socket in the corner of the door before you pull it. After the new door is mounted and the unit is powered, the backlit \u003cstrong\u003ePOWER\u003c\/strong\u003e and \u003cstrong\u003eRESET\u003c\/strong\u003e buttons light up and the first \u003cstrong\u003egreen LED\u003c\/strong\u003e shows power is present. With the indoor fan running it flashes slowly, which tells you the \u003cstrong\u003efield charger\u003c\/strong\u003e and \u003cstrong\u003ecollection cells\u003c\/strong\u003e have power and the unit is operating normally. Wire the unit for \u003cstrong\u003ecommunicating mode\u003c\/strong\u003e: if it was temporarily converted to \u003cstrong\u003e24 volt mode\u003c\/strong\u003e, disconnect the 24 volt low-voltage wiring and reconnect per installation guide \u003cstrong\u003e18-HE53D1-11\u003c\/strong\u003e. On a \u003cstrong\u003eTrane 950 comfort control\u003c\/strong\u003e running software \u003cstrong\u003e2.2 or earlier\u003c\/strong\u003e, remove the old \u003cstrong\u003eoffline\u003c\/strong\u003e air cleaner from the equipment list on the \u003cstrong\u003eSummary Table\u003c\/strong\u003e screen before installing, then confirm the new device shows \u003cstrong\u003eOnline\u003c\/strong\u003e and \u003cstrong\u003eEnabled\u003c\/strong\u003e. The replacement board carries no model or serial number, so the \u003cstrong\u003eSystem Information\u003c\/strong\u003e screen displays \u003cstrong\u003eACCE\u003c\/strong\u003e and the software version only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFactory-Listed Fit:\u003c\/strong\u003e Named by Trane in \u003cstrong\u003eACC-SVB19D-EN\u003c\/strong\u003e as the door kit for the \u003cstrong\u003eAFD245CLFR000C\/D\u003c\/strong\u003e and \u003cstrong\u003eAFD24DCLFR000C\/D\u003c\/strong\u003e air cleaners, not a universal cross-fit.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eComplete Door Assembly:\u003c\/strong\u003e Door, \u003cstrong\u003econtrol board\u003c\/strong\u003e and \u003cstrong\u003epower pack\u003c\/strong\u003e come as one assembly, the replacement Trane recommends on \u003cstrong\u003emultiple air cleaner\u003c\/strong\u003e systems.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCommunicating-Mode Ready:\u003c\/strong\u003e Built for \u003cstrong\u003ecommunicating mode\u003c\/strong\u003e so the air cleaner reports to the \u003cstrong\u003ecomfort control\u003c\/strong\u003e and clears the \u003cstrong\u003ecommunicating errors\u003c\/strong\u003e described in the bulletin.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Trane Part:\u003c\/strong\u003e A \u003cstrong\u003egenuine Trane\u003c\/strong\u003e replacement that restores power to the \u003cstrong\u003efield charger\u003c\/strong\u003e and \u003cstrong\u003ecollection cells\u003c\/strong\u003e to factory specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhich air cleaners does KIT16529 fit?\u003c\/strong\u003e Per Trane bulletin \u003cstrong\u003eACC-SVB19D-EN\u003c\/strong\u003e, the \u003cstrong\u003eAFD245CLFR000C\u003c\/strong\u003e, \u003cstrong\u003eAFD245CLFR000D\u003c\/strong\u003e, \u003cstrong\u003eAFD24DCLFR000C\u003c\/strong\u003e and \u003cstrong\u003eAFD24DCLFR000D\u003c\/strong\u003e \u003cstrong\u003eAccuClean \/ CleanEffects\u003c\/strong\u003e models.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan I use it on a Trane TFD245 unit?\u003c\/strong\u003e No. The \u003cstrong\u003eTFD245CLFR000C\/D\u003c\/strong\u003e and \u003cstrong\u003eTFD24DCLFR000C\/D\u003c\/strong\u003e models use \u003cstrong\u003eKIT16536\u003c\/strong\u003e. Always match the kit to the full model number on the nameplate.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo I replace the whole door or just the control board?\u003c\/strong\u003e Trane's bulletin calls for the \u003cstrong\u003econtrol board CNT06888\u003c\/strong\u003e alone on a system with one air cleaner, and for the \u003cstrong\u003eentire door assembly\u003c\/strong\u003e such as \u003cstrong\u003eKIT16529\u003c\/strong\u003e when a system has multiple air cleaners.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Trane","offers":[{"title":"Default Title","offer_id":67881559949490,"sku":"KIT16529","price":1199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_d8f6c0df-eeb5-4a7f-8ee2-4f92681ea310.webp?v=1755632728","url":"https:\/\/www.gsistore.com\/en-ca\/products\/trane-kit16529","provider":"GSIstore","version":"1.0","type":"link"}