{"product_id":"weil-mclain-383-500-397","title":"Weil McLain 383-500-397 Termination Kit","description":"\u003cp\u003eThe \u003cstrong\u003eWeil McLain 383-500-397 3 Inch PVC Sidewall Vent Termination Kit\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e \u003cstrong\u003esidewall termination\u003c\/strong\u003e for \u003cstrong\u003eWeil-McLain\u003c\/strong\u003e \u003cstrong\u003eUltra\u003c\/strong\u003e gas boilers in the \u003cstrong\u003eUltra-80\u003c\/strong\u003e through \u003cstrong\u003eUltra-155\u003c\/strong\u003e sizes and for \u003cstrong\u003eGV90+\u003c\/strong\u003e boilers. It terminates the \u003cstrong\u003event\u003c\/strong\u003e and the \u003cstrong\u003ecombustion air\u003c\/strong\u003e pipe on an outside wall in a single \u003cstrong\u003event\/air cap\u003c\/strong\u003e. The kit contains the \u003cstrong\u003esidewall vent\/air termination cap\u003c\/strong\u003e, an \u003cstrong\u003einside cover plate\u003c\/strong\u003e, an \u003cstrong\u003eoutside cover plate\u003c\/strong\u003e and the \u003cstrong\u003emounting hardware\u003c\/strong\u003e, and the openings in the cap are sized for \u003cstrong\u003e3-inch\u003c\/strong\u003e \u003cstrong\u003ePVC\u003c\/strong\u003e pipe.\u003c\/p\u003e\n\n\u003cp\u003eA \u003cstrong\u003edirect vent\u003c\/strong\u003e boiler needs both an exhaust outlet and an air inlet on the outside of the building, and the termination is where they meet the weather. The \u003cstrong\u003event\/air cap\u003c\/strong\u003e holds the two pipes at the spacing the manufacturer requires so the exhaust cannot be drawn back into the air intake, and the \u003cstrong\u003ecover plates\u003c\/strong\u003e close off the wall opening on the inside and the outside so the penetration looks finished. Weil-McLain sells this kit in two pipe sizes: the \u003cstrong\u003e383-500-397\u003c\/strong\u003e is the \u003cstrong\u003e3-inch\u003c\/strong\u003e kit for the \u003cstrong\u003eUltra-80\u003c\/strong\u003e through \u003cstrong\u003eUltra-155\u003c\/strong\u003e and the \u003cstrong\u003eGV90+\u003c\/strong\u003e, and the \u003cstrong\u003e383-500-398\u003c\/strong\u003e is the separate \u003cstrong\u003e4-inch\u003c\/strong\u003e sidewall kit. Weil-McLain also carries other termination kits such as the \u003cstrong\u003e383-500-350\u003c\/strong\u003e, so the part number decides the match. A damaged, cracked or missing cap is more than cosmetic, because a blocked or distorted termination can restrict the exhaust and interrupt boiler operation.\u003c\/p\u003e\n\n\u003cp\u003eUse the vent supplement or installation manual for the specific boiler for the clearances, pipe lengths and approved \u003cstrong\u003ePVC\u003c\/strong\u003e materials, and follow the manual for the wall penetration, the cap orientation and the minimum distances to windows, doors, meters and the ground. Dry-fit the cap, mark and cut the wall opening, seal the penetration, glue the pipe joints with the correct \u003cstrong\u003eprimer\u003c\/strong\u003e and \u003cstrong\u003ecement\u003c\/strong\u003e, and support the pipes so nothing hangs from the cap. Allow the cement to cure before firing, then confirm that the cap is clear of snow, debris and vegetation and that exhaust cannot re-enter the intake. Check the boiler model against the \u003cstrong\u003e3-inch\u003c\/strong\u003e sizes above before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eComplete Termination Kit:\u003c\/strong\u003e Includes the \u003cstrong\u003event\/air cap\u003c\/strong\u003e, \u003cstrong\u003einside cover plate\u003c\/strong\u003e, \u003cstrong\u003eoutside cover plate\u003c\/strong\u003e and \u003cstrong\u003emounting hardware\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSized For 3-Inch PVC:\u003c\/strong\u003e Openings are made for \u003cstrong\u003e3-inch\u003c\/strong\u003e \u003cstrong\u003ePVC\u003c\/strong\u003e pipe on the \u003cstrong\u003eUltra-80\u003c\/strong\u003e through \u003cstrong\u003eUltra-155\u003c\/strong\u003e and the \u003cstrong\u003eGV90+\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFinished Wall Opening:\u003c\/strong\u003e The \u003cstrong\u003einside cover plate\u003c\/strong\u003e and \u003cstrong\u003eoutside cover plate\u003c\/strong\u003e trim the wall opening on both sides.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Weil-McLain Part:\u003c\/strong\u003e Matches the termination Weil-McLain specifies, separate from the \u003cstrong\u003e4-inch\u003c\/strong\u003e \u003cstrong\u003e383-500-398\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhich boilers use this kit?\u003c\/strong\u003e The \u003cstrong\u003eUltra-80\u003c\/strong\u003e through \u003cstrong\u003eUltra-155\u003c\/strong\u003e and the \u003cstrong\u003eGV90+\u003c\/strong\u003e. The \u003cstrong\u003e4-inch\u003c\/strong\u003e kit is the separate \u003cstrong\u003e383-500-398\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is in the kit?\u003c\/strong\u003e The \u003cstrong\u003esidewall vent\/air termination cap\u003c\/strong\u003e, an \u003cstrong\u003einside cover plate\u003c\/strong\u003e, an \u003cstrong\u003eoutside cover plate\u003c\/strong\u003e and \u003cstrong\u003emounting hardware\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAre there other termination kits?\u003c\/strong\u003e Yes. Weil-McLain carries others, including the \u003cstrong\u003e383-500-350\u003c\/strong\u003e, so match the number to the boiler and the pipe size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Weil McLain","offers":[{"title":"Default Title","offer_id":68120328700082,"sku":"383-500-397","price":181.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_d8f6c0df-eeb5-4a7f-8ee2-4f92681ea310.webp?v=1755632728","url":"https:\/\/www.gsistore.com\/en-ca\/products\/weil-mclain-383-500-397","provider":"GSIstore","version":"1.0","type":"link"}