{"product_id":"burnham-boiler-101015-01","title":"Burnham Boiler 101015-01 Temperature Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham Boiler 101015-01 Flue Gas Temperature Sensor\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e \u003cstrong\u003eflue gas sensor\u003c\/strong\u003e for \u003cstrong\u003eCHG\u003c\/strong\u003e and \u003cstrong\u003eFreedom\u003c\/strong\u003e boilers. It measures the temperature of the \u003cstrong\u003eexhaust gases\u003c\/strong\u003e leaving the boiler and passes that reading to the \u003cstrong\u003eboiler control\u003c\/strong\u003e, so the control always knows what the \u003cstrong\u003eflue\u003c\/strong\u003e is doing while the \u003cstrong\u003eburner\u003c\/strong\u003e fires. The sensor arrives with a gray \u003cstrong\u003erubber grommet\u003c\/strong\u003e, a \u003cstrong\u003emetal bracket\u003c\/strong\u003e and a \u003cstrong\u003emounting screw\u003c\/strong\u003e, which is the hardware that holds the \u003cstrong\u003eprobe\u003c\/strong\u003e in position at the \u003cstrong\u003eflue outlet\u003c\/strong\u003e and keeps the lead from chafing on the metal around it.\u003c\/p\u003e\n\n\u003cp\u003eThe reading matters for two reasons. First, \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e is a direct clue to \u003cstrong\u003ecombustion\u003c\/strong\u003e quality and \u003cstrong\u003eheat exchanger\u003c\/strong\u003e condition: exhaust that runs hotter than normal points to a dirty \u003cstrong\u003eheat exchanger\u003c\/strong\u003e, a fouled \u003cstrong\u003eburner\u003c\/strong\u003e or a boiler that is overfiring. Second, the control uses the value as a safety input, so an exhaust temperature that climbs past the allowed limit can cause the boiler to reduce output or shut down before the \u003cstrong\u003eventing\u003c\/strong\u003e is stressed. A sensor that has drifted, corroded or opened shows up as a \u003cstrong\u003eflue temperature fault\u003c\/strong\u003e, a nuisance \u003cstrong\u003elockout\u003c\/strong\u003e, or a boiler that cuts back for no visible reason. Because the probe lives in hot, wet exhaust, the usual causes of failure are a \u003cstrong\u003ecorroded probe\u003c\/strong\u003e, a brittle \u003cstrong\u003ewire jacket\u003c\/strong\u003e and a loose \u003cstrong\u003econnector\u003c\/strong\u003e or terminal.\u003c\/p\u003e\n\n\u003cp\u003eReplacement is straightforward on a cold boiler with the power off. Note how the old \u003cstrong\u003eprobe\u003c\/strong\u003e sits in the \u003cstrong\u003ebracket\u003c\/strong\u003e and how deep it reaches, fit the new \u003cstrong\u003egrommet\u003c\/strong\u003e so it seals around the lead, route the wire away from hot surfaces and reconnect it at the control. After the boiler is back in service, compare the displayed \u003cstrong\u003eflue temperature\u003c\/strong\u003e with a calibrated \u003cstrong\u003ecombustion analyzer\u003c\/strong\u003e so you know the new sensor tracks the real exhaust. Burnham uses different flue sensors on different boiler families: the \u003cstrong\u003eK2\u003c\/strong\u003e series takes the \u003cstrong\u003e105883-01\u003c\/strong\u003e, while \u003cstrong\u003eCHG\u003c\/strong\u003e and \u003cstrong\u003eFreedom\u003c\/strong\u003e boilers take this \u003cstrong\u003e101015-01\u003c\/strong\u003e, so match the part to the boiler series and the model on the rating plate before you order.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDirect Flue Readings:\u003c\/strong\u003e Reports \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e to the \u003cstrong\u003eboiler control\u003c\/strong\u003e so \u003cstrong\u003efiring\u003c\/strong\u003e and \u003cstrong\u003esafety limits\u003c\/strong\u003e act on real exhaust data.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCHG And Freedom Sensor:\u003c\/strong\u003e The \u003cstrong\u003eOEM\u003c\/strong\u003e \u003cstrong\u003eflue gas temperature sensor\u003c\/strong\u003e used on \u003cstrong\u003eCHG\u003c\/strong\u003e and \u003cstrong\u003eFreedom\u003c\/strong\u003e boilers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting Hardware Included:\u003c\/strong\u003e A \u003cstrong\u003erubber grommet\u003c\/strong\u003e, \u003cstrong\u003emetal bracket\u003c\/strong\u003e and \u003cstrong\u003escrew\u003c\/strong\u003e come with the \u003cstrong\u003e101015-01\u003c\/strong\u003e for a clean install.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEarly Warning:\u003c\/strong\u003e A healthy sensor lets the control catch a dirty \u003cstrong\u003eheat exchanger\u003c\/strong\u003e or \u003cstrong\u003eoverfiring\u003c\/strong\u003e before the \u003cstrong\u003eventing\u003c\/strong\u003e suffers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat does a flue gas temperature sensor do?\u003c\/strong\u003e It measures \u003cstrong\u003eexhaust gas temperature\u003c\/strong\u003e and sends the value to the \u003cstrong\u003eboiler control\u003c\/strong\u003e for \u003cstrong\u003ecombustion\u003c\/strong\u003e and \u003cstrong\u003esafety limit\u003c\/strong\u003e decisions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs this the same sensor the K2 series uses?\u003c\/strong\u003e No. The \u003cstrong\u003eK2\u003c\/strong\u003e series uses the \u003cstrong\u003e105883-01\u003c\/strong\u003e. This \u003cstrong\u003e101015-01\u003c\/strong\u003e is for \u003cstrong\u003eCHG\u003c\/strong\u003e and \u003cstrong\u003eFreedom\u003c\/strong\u003e boilers.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat are the signs of a failing sensor?\u003c\/strong\u003e A \u003cstrong\u003eflue temperature fault\u003c\/strong\u003e, an unexplained \u003cstrong\u003elockout\u003c\/strong\u003e, or readings that never change as the boiler runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68120326799538,"sku":"101015-01","price":78.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/101015-01.jpg?v=1795307843","url":"https:\/\/www.gsistore.com\/products\/burnham-boiler-101015-01","provider":"GSIstore","version":"1.0","type":"link"}