{"product_id":"burnham-boiler-104999-03","title":"Burnham Boiler 104999-03 Blower Motor","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham Boiler 104999-03 Blower Motor Assembly\u003c\/strong\u003e is the replacement \u003cstrong\u003einducer and combustion blower\u003c\/strong\u003e for the \u003cstrong\u003eAPX825\u003c\/strong\u003e \u003cstrong\u003eboiler\u003c\/strong\u003e. On a \u003cstrong\u003ecommercial condensing boiler\u003c\/strong\u003e of this class, the \u003cstrong\u003eblower\u003c\/strong\u003e governs how much fire the unit can make. It purges the \u003cstrong\u003ecombustion chamber\u003c\/strong\u003e before ignition, meters air to the \u003cstrong\u003epremix burner\u003c\/strong\u003e across the modulation range and moves flue gas through the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e to the \u003cstrong\u003event\u003c\/strong\u003e. A weak or failed \u003cstrong\u003eblower\u003c\/strong\u003e can take a whole building loop offline, which makes this one of the parts worth identifying correctly the first time.\u003c\/p\u003e\n\n\u003cp\u003eThe kit consists of the \u003cstrong\u003eblower\u003c\/strong\u003e assembly with its cast aluminum scroll and square outlet flange, a gray \u003cstrong\u003emotor cover\u003c\/strong\u003e, a matching square \u003cstrong\u003eoutlet gasket\u003c\/strong\u003e and \u003cstrong\u003emounting hardware\u003c\/strong\u003e. Because \u003cstrong\u003e104999-03\u003c\/strong\u003e is a \u003cstrong\u003ereplacement blower kit\u003c\/strong\u003e with the \u003cstrong\u003eblower\u003c\/strong\u003e, the \u003cstrong\u003eoutlet gasket\u003c\/strong\u003e and the hardware together, the items disturbed at the outlet joint can be renewed during the same visit. The \u003cstrong\u003emotor cover\u003c\/strong\u003e carries an electrical hazard symbol as a reminder that line voltage is present. Respect it, and lock out power before you reach into the cabinet.\u003c\/p\u003e\n\n\u003cp\u003eStart with a disciplined diagnosis. Measure \u003cstrong\u003esupply voltage\u003c\/strong\u003e, check the \u003cstrong\u003espeed control signal\u003c\/strong\u003e and feedback wiring, and look at the connectors for discoloration. Confirm that the intake, \u003cstrong\u003event\u003c\/strong\u003e, \u003cstrong\u003econdensate drain\u003c\/strong\u003e and \u003cstrong\u003eheat exchanger\u003c\/strong\u003e are not creating a restriction that mimics a \u003cstrong\u003eblower\u003c\/strong\u003e fault. If the \u003cstrong\u003emotor\u003c\/strong\u003e or wheel has failed, shut off gas and electricity, document the wiring and support the assembly while removing it, since it is a substantial component. Clean the mating surfaces, fit the new \u003cstrong\u003egasket\u003c\/strong\u003e and tighten the fasteners evenly. Test every gas joint that was opened, then run the \u003cstrong\u003eboiler\u003c\/strong\u003e through its full firing range and set combustion with an \u003cstrong\u003eanalyzer\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMatched to the APX825:\u003c\/strong\u003e Identified for the \u003cstrong\u003eAPX825\u003c\/strong\u003e, which helps you separate it from blowers used on other \u003cstrong\u003eboiler\u003c\/strong\u003e sizes in the same product line.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutlet Gasket and Hardware:\u003c\/strong\u003e A new square \u003cstrong\u003egasket\u003c\/strong\u003e and fasteners come with the \u003cstrong\u003eblower\u003c\/strong\u003e, so the outlet joint is rebuilt with fresh parts.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRestores Modulation:\u003c\/strong\u003e A healthy \u003cstrong\u003emotor\u003c\/strong\u003e and wheel let the \u003cstrong\u003eboiler\u003c\/strong\u003e purge, light off and modulate smoothly instead of tripping on fan speed faults.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFactory Replacement Number:\u003c\/strong\u003e Ordering by \u003cstrong\u003e104999-03\u003c\/strong\u003e ties the repair to the manufacturer part and avoids adapting a generic fan to a gas fired appliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat boiler uses the 104999-03 blower?\u003c\/strong\u003e It is identified for the \u003cstrong\u003eAPX825\u003c\/strong\u003e. Check the rating label and the repair parts section of your manual to confirm the number before ordering.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat is included with the assembly?\u003c\/strong\u003e The \u003cstrong\u003eblower motor assembly\u003c\/strong\u003e, the square \u003cstrong\u003eoutlet gasket\u003c\/strong\u003e and \u003cstrong\u003emounting hardware\u003c\/strong\u003e. Reuse no seal that shows compression, cracking or contamination.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhy check venting before replacing the blower?\u003c\/strong\u003e A blocked \u003cstrong\u003event\u003c\/strong\u003e, intake or \u003cstrong\u003eheat exchanger\u003c\/strong\u003e can cause poor airflow readings and fan related lockouts. Clearing those first prevents replacing a good part and leaving the real fault behind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68192092127410,"sku":"104999-03","price":2191.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/104999-03.jpg?v=1795809284","url":"https:\/\/www.gsistore.com\/products\/burnham-boiler-104999-03","provider":"GSIstore","version":"1.0","type":"link"}