{"product_id":"burnham-boiler-105883-01","title":"Burnham Boiler 105883-01 Temperature Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham Boiler 105883-01 Flue Temperature Sensor\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e probe that reports \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e to the boiler control. It is the sensor used on the \u003cstrong\u003eK2\u003c\/strong\u003e series condensing boilers and is part of the \u003cstrong\u003eK2, K2 Combi and X-C service kit\u003c\/strong\u003e that \u003cstrong\u003eBurnham\u003c\/strong\u003e publishes for annual maintenance. The probe plugs into the control through a \u003cstrong\u003ewhite connector\u003c\/strong\u003e and extends a short \u003cstrong\u003esensing probe\u003c\/strong\u003e into the flue outlet, where it measures the temperature of the exhaust leaving the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe control uses that reading in two ways. During normal operation it follows \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e as a guide to combustion and heat-exchanger condition, and if the exhaust climbs past a safe limit it can reduce \u003cstrong\u003efiring rate\u003c\/strong\u003e or shut the burner down to protect the \u003cstrong\u003eventing\u003c\/strong\u003e and the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e. A drifting or open sensor therefore shows up as a \u003cstrong\u003eflue temperature fault\u003c\/strong\u003e, a nuisance lockout, or a boiler that derates for no visible reason. Because the sensor sits in the hottest part of the \u003cstrong\u003eexhaust path\u003c\/strong\u003e, the \u003cstrong\u003eprobe\u003c\/strong\u003e and its \u003cstrong\u003elead\u003c\/strong\u003e see constant heat and \u003cstrong\u003econdensate\u003c\/strong\u003e exposure, so a \u003cstrong\u003ecorroded probe\u003c\/strong\u003e, a brittle \u003cstrong\u003ewire jacket\u003c\/strong\u003e or a loose \u003cstrong\u003econnector\u003c\/strong\u003e are the usual reasons for replacement. A visual check of the sensor and its \u003cstrong\u003eseal\u003c\/strong\u003e belongs in every annual service, and a quick comparison of the reading against a calibrated \u003cstrong\u003ecombustion analyzer\u003c\/strong\u003e confirms whether the sensor tracks the real exhaust temperature.\u003c\/p\u003e\n\n\u003cp\u003eReplace the \u003cstrong\u003e105883-01\u003c\/strong\u003e when a diagnostic points to the flue sensor, when the probe is corroded, or when the connector or wiring has been damaged. Disconnect power first, seat the probe the same way the original sat, and keep the \u003cstrong\u003esensor wire\u003c\/strong\u003e clear of hot surfaces. On \u003cstrong\u003eCHG\u003c\/strong\u003e and \u003cstrong\u003eFreedom\u003c\/strong\u003e boilers the flue gas sensor is a different part, \u003cstrong\u003e101015-01\u003c\/strong\u003e, so match the boiler series before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAccurate Flue Readings:\u003c\/strong\u003e The probe reports \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e to the control so \u003cstrong\u003efiring rate\u003c\/strong\u003e and safety limits act on real exhaust data.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eK2 Service Part:\u003c\/strong\u003e Specified by \u003cstrong\u003eBurnham\u003c\/strong\u003e for the \u003cstrong\u003eK2\u003c\/strong\u003e series and carried in the \u003cstrong\u003eK2 service kit\u003c\/strong\u003e parts list.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePlug-In Connection:\u003c\/strong\u003e A \u003cstrong\u003ewhite connector\u003c\/strong\u003e on the lead mates with the control harness, so no rewiring is involved.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtects the Venting:\u003c\/strong\u003e A working sensor lets the control back off or stop the burner before \u003cstrong\u003eventing\u003c\/strong\u003e and the \u003cstrong\u003eheat exchanger\u003c\/strong\u003e see excess heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat does this sensor do?:\u003c\/strong\u003e It measures \u003cstrong\u003eflue gas temperature\u003c\/strong\u003e and sends the value to the boiler control for \u003cstrong\u003ecombustion\u003c\/strong\u003e and \u003cstrong\u003esafety limit\u003c\/strong\u003e decisions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs it the same sensor as the CHG and Freedom boilers use?:\u003c\/strong\u003e No. Those boilers use \u003cstrong\u003e101015-01\u003c\/strong\u003e; the \u003cstrong\u003e105883-01\u003c\/strong\u003e is for the \u003cstrong\u003eK2\u003c\/strong\u003e series.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat symptoms point to a bad flue sensor?:\u003c\/strong\u003e A \u003cstrong\u003eflue temperature fault\u003c\/strong\u003e code, an unexplained lockout, or readings that do not change as the boiler runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68111252783282,"sku":"105883-01","price":44.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/105883-01.jpg?v=1795219091","url":"https:\/\/www.gsistore.com\/products\/burnham-boiler-105883-01","provider":"GSIstore","version":"1.0","type":"link"}