{"product_id":"burnham-boiler-107866-01","title":"Burnham 107866-01 Gas Valve Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham 107866-01 Blower\/Gas Valve Assembly\u003c\/strong\u003e is the OEM combination \u003cstrong\u003eblower and gas valve\u003c\/strong\u003e assembly for \u003cstrong\u003eBurnham 120 and 150\u003c\/strong\u003e size boilers. It joins the \u003cstrong\u003edraft inducer blower\u003c\/strong\u003e and the \u003cstrong\u003egas valve\u003c\/strong\u003e into one factory-matched assembly, which is why it is replaced as a unit. The blower moves \u003cstrong\u003ecombustion air\u003c\/strong\u003e through the burner and heat exchanger, the \u003cstrong\u003egas valve\u003c\/strong\u003e meters fuel into that airflow, and the two together set the \u003cstrong\u003eair-to-fuel ratio\u003c\/strong\u003e that determines how clean, stable and efficient the flame is. Because the pair is matched at the factory, there is no need to source and pair a blower and a gas valve separately.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBurnham\u003c\/strong\u003e builds this assembly by boiler size. The \u003cstrong\u003e107866-01\u003c\/strong\u003e is the \u003cstrong\u003e120\/150\u003c\/strong\u003e assembly, the \u003cstrong\u003e107869-01\u003c\/strong\u003e is the \u003cstrong\u003e080\/100\u003c\/strong\u003e assembly and the \u003cstrong\u003e107867-01\u003c\/strong\u003e is the \u003cstrong\u003e180\u003c\/strong\u003e assembly, so the size on the boiler's rating plate decides which number is correct. Gas valves are fuel specific, so confirm the boiler's \u003cstrong\u003egas type\u003c\/strong\u003e along with its size, and order by model and serial number rather than by size alone. A wrong assembly means wrong airflow and gas flow, which shows up as poor combustion readings, rough ignition or a boiler that will not hold a stable flame.\u003c\/p\u003e\n\n\u003cp\u003eThe signs of a failing assembly include a blower that runs noisy or rough, a flame that is unstable or lazy, ignition failures, combustion readings that cannot be brought into range, and a gas valve that does not open or that leaks by. Before replacing it, confirm the gas supply pressure, the vent and combustion air intake, the condensate drain and the wiring plugs. Gas work belongs to a qualified technician: shut off the gas and power, disconnect the gas connection, remove the old assembly, install the \u003cstrong\u003e107866-01\u003c\/strong\u003e, reconnect the plugs, restore the gas, leak-test every joint with an approved method and verify combustion with an analyzer before leaving the boiler in service.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMatched Blower and Valve:\u003c\/strong\u003e The \u003cstrong\u003eblower\u003c\/strong\u003e and \u003cstrong\u003egas valve\u003c\/strong\u003e come as one factory-matched assembly, so the \u003cstrong\u003eair-to-fuel ratio\u003c\/strong\u003e starts from the original design.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSized for 120 and 150:\u003c\/strong\u003e The \u003cstrong\u003e107866-01\u003c\/strong\u003e is the assembly for \u003cstrong\u003eBurnham 120\/150\u003c\/strong\u003e size boilers, with sister numbers \u003cstrong\u003e107869-01\u003c\/strong\u003e for \u003cstrong\u003e080\/100\u003c\/strong\u003e and \u003cstrong\u003e107867-01\u003c\/strong\u003e for \u003cstrong\u003e180\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRestores Stable Combustion:\u003c\/strong\u003e A new assembly restores steady \u003cstrong\u003ecombustion air\u003c\/strong\u003e delivery and accurate \u003cstrong\u003egas flow\u003c\/strong\u003e control.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGenuine OEM:\u003c\/strong\u003e A factory \u003cstrong\u003eBurnham\u003c\/strong\u003e assembly built to the original specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat boiler sizes use the 107866-01?\u003c\/strong\u003e \u003cstrong\u003eBurnham 120 and 150\u003c\/strong\u003e size boilers. The \u003cstrong\u003e107869-01\u003c\/strong\u003e is for \u003cstrong\u003e080\/100\u003c\/strong\u003e and the \u003cstrong\u003e107867-01\u003c\/strong\u003e is for \u003cstrong\u003e180\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhy is the blower sold with the gas valve?\u003c\/strong\u003e The two work together to set the \u003cstrong\u003eair-to-fuel ratio\u003c\/strong\u003e, so \u003cstrong\u003eBurnham\u003c\/strong\u003e supplies them as one matched \u003cstrong\u003eblower\/gas valve assembly\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDoes gas type matter?\u003c\/strong\u003e Yes. Gas valves are fuel specific, so confirm \u003cstrong\u003enatural gas\u003c\/strong\u003e or \u003cstrong\u003epropane\u003c\/strong\u003e along with the boiler size and order by model and serial number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68096125042866,"sku":"107866-01","price":680.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_d8f6c0df-eeb5-4a7f-8ee2-4f92681ea310.webp?v=1755632728","url":"https:\/\/www.gsistore.com\/products\/burnham-boiler-107866-01","provider":"GSIstore","version":"1.0","type":"link"}