{"product_id":"burnham-boiler-107867-01","title":"Burnham Boiler 107867-01 Gas Valve Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBurnham Boiler 107867-01 Blower\/Gas Valve Assembly\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e replacement for the \u003cstrong\u003e180\u003c\/strong\u003e size \u003cstrong\u003eBurnham\u003c\/strong\u003e boiler. It combines the \u003cstrong\u003eblower\u003c\/strong\u003e and the \u003cstrong\u003egas valve\u003c\/strong\u003e in one integrated assembly, so the air supply and the fuel supply are replaced as a matched pair. The \u003cstrong\u003eblower\u003c\/strong\u003e provides the \u003cstrong\u003ecombustion air\u003c\/strong\u003e and the valve meters the gas into that air, and the two have to work together to hold the correct \u003cstrong\u003eair-fuel ratio\u003c\/strong\u003e across the firing range. A single factory assembly keeps that relationship the way \u003cstrong\u003eBurnham\u003c\/strong\u003e built it.\u003c\/p\u003e\n\n\u003cp\u003eWhen this assembly is wearing out, the boiler gives clear hints. You may see a \u003cstrong\u003eblower fault\u003c\/strong\u003e, a \u003cstrong\u003egas valve fault\u003c\/strong\u003e, hard or delayed lighting, a \u003cstrong\u003eflame\u003c\/strong\u003e that will not hold steady, a \u003cstrong\u003eflame failure\u003c\/strong\u003e lockout or a boiler that refuses to modulate. Swapping the whole assembly is often the quickest way to a clean repair because it takes away the question of whether the air side or the fuel side is at fault. Burnham numbers the assembly by boiler size, so the \u003cstrong\u003e107867-01\u003c\/strong\u003e is the \u003cstrong\u003e180\u003c\/strong\u003e, the \u003cstrong\u003e107869-01\u003c\/strong\u003e is the \u003cstrong\u003e80\u003c\/strong\u003e and \u003cstrong\u003e100\u003c\/strong\u003e, and the \u003cstrong\u003e107866-01\u003c\/strong\u003e is the \u003cstrong\u003e120\u003c\/strong\u003e and \u003cstrong\u003e150\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003egas valve\u003c\/strong\u003e is part of this assembly, so installation is work for a licensed technician. Close the manual gas valve, switch off the power, disconnect the leads and remove the old assembly. Fit the new one with fresh seals on every joint, reconnect the wiring and restore gas and power. Leak-test every connection, fire the boiler and verify \u003cstrong\u003egas pressure\u003c\/strong\u003e, \u003cstrong\u003eflame\u003c\/strong\u003e signal and \u003cstrong\u003ecombustion\u003c\/strong\u003e with an analyzer at low fire and high fire. Check the boiler size on the rating plate before ordering, because the \u003cstrong\u003e180\u003c\/strong\u003e assembly is a different part from the smaller-size assemblies, and do not substitute one for another.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBlower And Valve As One:\u003c\/strong\u003e Replaces the \u003cstrong\u003eblower\u003c\/strong\u003e and \u003cstrong\u003egas valve\u003c\/strong\u003e together so \u003cstrong\u003ecombustion air\u003c\/strong\u003e and \u003cstrong\u003efuel\u003c\/strong\u003e stay in proportion.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSized For The 180:\u003c\/strong\u003e The \u003cstrong\u003e107867-01\u003c\/strong\u003e is the assembly for the \u003cstrong\u003e180\u003c\/strong\u003e, separate from the \u003cstrong\u003e107869-01\u003c\/strong\u003e and \u003cstrong\u003e107866-01\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOEM Factory Part:\u003c\/strong\u003e Made to \u003cstrong\u003eBurnham\u003c\/strong\u003e specifications for steady \u003cstrong\u003eair-fuel ratio\u003c\/strong\u003e and reliable lighting.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFast Repair:\u003c\/strong\u003e One integrated assembly resolves \u003cstrong\u003eblower\u003c\/strong\u003e and \u003cstrong\u003egas valve\u003c\/strong\u003e problems without guessing which half failed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhich boiler size is it for?\u003c\/strong\u003e The \u003cstrong\u003e180\u003c\/strong\u003e size \u003cstrong\u003eBurnham\u003c\/strong\u003e boiler. Confirm the size on the rating plate.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat are the other sizes?\u003c\/strong\u003e The \u003cstrong\u003e107869-01\u003c\/strong\u003e is for the \u003cstrong\u003e80\u003c\/strong\u003e and \u003cstrong\u003e100\u003c\/strong\u003e, and the \u003cstrong\u003e107866-01\u003c\/strong\u003e is for the \u003cstrong\u003e120\u003c\/strong\u003e and \u003cstrong\u003e150\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat should be checked after installation?\u003c\/strong\u003e Leak-test the \u003cstrong\u003egas train\u003c\/strong\u003e connections, then verify \u003cstrong\u003egas pressure\u003c\/strong\u003e, \u003cstrong\u003eflame\u003c\/strong\u003e signal and \u003cstrong\u003ecombustion\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Burnham Boiler","offers":[{"title":"Default Title","offer_id":68120328339634,"sku":"107867-01","price":680.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_d8f6c0df-eeb5-4a7f-8ee2-4f92681ea310.webp?v=1755632728","url":"https:\/\/www.gsistore.com\/products\/burnham-boiler-107867-01","provider":"GSIstore","version":"1.0","type":"link"}