{"product_id":"copeland-510-7002-54","title":"Copeland 510-7002-54 Solenoid Valve","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland 510-7002-54\u003c\/strong\u003e is an OEM \u003cstrong\u003esolenoid valve with a 120 V coil\u003c\/strong\u003e for \u003cstrong\u003erefrigerant flow control\u003c\/strong\u003e in refrigeration and air conditioning circuits. The photo shows the complete assembly: a cast \u003cstrong\u003ebrass valve body\u003c\/strong\u003e with \u003cstrong\u003ecopper sweat connection stubs\u003c\/strong\u003e on each side, a \u003cstrong\u003eCopeland coil, type AMC\u003c\/strong\u003e, held on the valve with a \u003cstrong\u003espring retaining clip\u003c\/strong\u003e, and a \u003cstrong\u003ejacketed two-conductor lead\u003c\/strong\u003e with a cable tie. The coil label reads \u003cstrong\u003e120 volts\u003c\/strong\u003e, \u003cstrong\u003e17\/12 watts\u003c\/strong\u003e (inrush and holding), \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e, \u003cstrong\u003ecoil assembled in Mexico\u003c\/strong\u003e, and carries the \u003cstrong\u003e510-7002-54\u003c\/strong\u003e number alongside the factory code \u003cstrong\u003eGS-2214-3\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eA \u003cstrong\u003esolenoid valve\u003c\/strong\u003e is an electrically operated shutoff: current in the coil creates a magnetic field that moves an internal \u003cstrong\u003eplunger\u003c\/strong\u003e to open or close the valve port, giving the system a clean \u003cstrong\u003eon\/off\u003c\/strong\u003e control of refrigerant flow without a mechanical linkage. It is used where a circuit must be isolated or released on a signal from a thermostat, pressure control or controller, which also helps protect the \u003cstrong\u003ecompressor\u003c\/strong\u003e from flooding and keeps unwanted refrigerant migration out of the evaporator during the off cycle. This \u003cstrong\u003e510-7002-54\u003c\/strong\u003e is the \u003cstrong\u003e120 V\u003c\/strong\u003e version; the \u003cstrong\u003e208-240 V\u003c\/strong\u003e version in the same Copeland series is \u003cstrong\u003e510-7002-31\u003c\/strong\u003e, so verify the \u003cstrong\u003econtrol voltage\u003c\/strong\u003e in your circuit before ordering, because a coil on the wrong voltage will either not pull in or will burn out quickly.\u003c\/p\u003e\n\n\u003cp\u003eThe usual failures are an \u003cstrong\u003eopen or shorted coil\u003c\/strong\u003e (no magnetic click when energized, a hot or discolored coil, or a tripped control circuit) and a \u003cstrong\u003evalve that sticks or leaks by\u003c\/strong\u003e because of debris or wear. First confirm the correct voltage at the coil leads, listen or feel for the \u003cstrong\u003eplunger action\u003c\/strong\u003e when the circuit is energized, and check the coil with a meter before replacing the whole valve. \u003cstrong\u003eNever energize a coil that is off the valve body\u003c\/strong\u003e, because it overheats within moments. Replacing the valve is a \u003cstrong\u003esealed-system repair\u003c\/strong\u003e: \u003cstrong\u003erecover the refrigerant\u003c\/strong\u003e per \u003cstrong\u003eEPA Section 608\u003c\/strong\u003e practice, remove the \u003cstrong\u003ecoil\u003c\/strong\u003e from the body and \u003cstrong\u003eprotect the valve body from heat\u003c\/strong\u003e while \u003cstrong\u003ebrazing\u003c\/strong\u003e, then \u003cstrong\u003epressure test\u003c\/strong\u003e, \u003cstrong\u003eevacuate\u003c\/strong\u003e and \u003cstrong\u003erecharge\u003c\/strong\u003e before returning the system to service. Mount the valve in the orientation the original used so the plunger works as designed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eComplete Valve and Coil Assembly:\u003c\/strong\u003e Pictured as a factory unit with the \u003cstrong\u003eCopeland AMC coil\u003c\/strong\u003e, \u003cstrong\u003eretaining clip\u003c\/strong\u003e, \u003cstrong\u003elead wire\u003c\/strong\u003e and \u003cstrong\u003esweat stubs\u003c\/strong\u003e already assembled.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e120 V Control:\u003c\/strong\u003e The \u003cstrong\u003e120 volt, 17\/12 watt, 50\/60 Hz\u003c\/strong\u003e coil is the right fit where the control circuit is line-voltage 120 V.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePositive On\/Off Refrigerant Control:\u003c\/strong\u003e Gives the circuit repeatable \u003cstrong\u003eisolation\u003c\/strong\u003e and \u003cstrong\u003erelease\u003c\/strong\u003e on command from the system controls.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCopeland OEM Part:\u003c\/strong\u003e Factory \u003cstrong\u003e510-7002-54\u003c\/strong\u003e labeling and construction, with the \u003cstrong\u003e-31\u003c\/strong\u003e (\u003cstrong\u003e208-240 V\u003c\/strong\u003e) sibling available when your control voltage differs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat voltage is the coil?\u003c\/strong\u003e The coil on the \u003cstrong\u003eCopeland 510-7002-54\u003c\/strong\u003e is labeled \u003cstrong\u003e120 volts\u003c\/strong\u003e, \u003cstrong\u003e17\/12 watts\u003c\/strong\u003e, \u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIs this the same as 510-7002-31?\u003c\/strong\u003e No. \u003cstrong\u003e510-7002-31\u003c\/strong\u003e is the \u003cstrong\u003e208-240 V\u003c\/strong\u003e version in the same series; \u003cstrong\u003e510-7002-54\u003c\/strong\u003e is the \u003cstrong\u003e120 V\u003c\/strong\u003e version.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCan I replace just the coil?\u003c\/strong\u003e If the coil is the only failed component and the valve opens and closes properly, a matching \u003cstrong\u003eCopeland coil\u003c\/strong\u003e may be all you need; if the valve body is stuck or leaking, replace the full \u003cstrong\u003evalve assembly\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland","offers":[{"title":"Default Title","offer_id":67659135385778,"sku":"510-7002-54","price":264.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/510-7002-54.jpg?v=1791482187","url":"https:\/\/www.gsistore.com\/products\/copeland-510-7002-54","provider":"GSIstore","version":"1.0","type":"link"}