{"product_id":"copeland-comfort-control-white-rodgers-1361-102-valve","title":"Copeland Comfort Control (White Rodgers) 1361-102 Valve","description":"\u003cp\u003eThe \u003cstrong\u003eCopeland Comfort Control (White Rodgers) 1361-102 Valve\u003c\/strong\u003e is a professional-grade \u003cstrong\u003e3\/4\" hydronic zone valve\u003c\/strong\u003e engineered for precision flow control in closed-loop heating systems. Operating on \u003cstrong\u003e24 VAC\u003c\/strong\u003e at 0.2 Amps, this 2-wire, normally closed component is a staple for contractors managing residential and commercial boiler zones. The \u003cstrong\u003e1300 Series\u003c\/strong\u003e design features a \u003cstrong\u003eself-aligning barrel-type valve stem\u003c\/strong\u003e that utilizes line pressure to ensure a tight seal without binding, making it highly reliable in systems with a \u003cstrong\u003emaximum operating pressure\u003c\/strong\u003e of 50 PSI.\u003c\/p\u003e\n\n\u003cp\u003eThis 3\/4\" sweat connection valve includes a built-in \u003cstrong\u003eauxiliary switch\u003c\/strong\u003e (end switch) rated for up to 2.0 Amps, allowing for seamless integration with burner circuits or circulator relays. Performance-wise, it delivers a high \u003cstrong\u003eflow capacity\u003c\/strong\u003e of 23.5 GPM with a maximum differential pressure of 15 PSI. For the service technician, the \u003cstrong\u003eremovable motor\u003c\/strong\u003e is a significant advantage, as it can be swapped without draining the hydronic loop. The \u003cstrong\u003eautomatic recycling manual operator\u003c\/strong\u003e provides a clear visual of the valve position, while the \u003cstrong\u003escrew terminal wiring panel\u003c\/strong\u003e simplifies field installation and diagnostic testing.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Reliability:\u003c\/strong\u003e The \u003cstrong\u003ecorrosion-resistant stainless steel body\u003c\/strong\u003e and self-aligning stem resist mineral buildup even at a \u003cstrong\u003emaximum media temperature\u003c\/strong\u003e of 240°F.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEfficient Servicing:\u003c\/strong\u003e The quick-release motor design allows for rapid replacement, minimizing downtime and labor costs during maintenance calls.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIntegrated Control:\u003c\/strong\u003e The internal \u003cstrong\u003eauxiliary switch\u003c\/strong\u003e eliminates the need for external relays when triggering a boiler or pump upon zone opening.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAccurate Monitoring:\u003c\/strong\u003e The \u003cstrong\u003emanual operator\u003c\/strong\u003e allows technicians to manually bypass the actuator to verify flow or check the heat loop without power.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBroad Compatibility:\u003c\/strong\u003e A direct \u003cstrong\u003eOEM replacement\u003c\/strong\u003e for various 1361-series valves, ensuring physical and electrical match in existing hydronic manifolds.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1361-102 be used for domestic potable water?\u003c\/strong\u003e\u003cbr\u003e\nNo, this valve is specifically designed for \u003cstrong\u003ehydronic heating systems\u003c\/strong\u003e and is not rated for potable or drinking water applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the valve opens but the boiler doesn't fire?\u003c\/strong\u003e\u003cbr\u003e\nVerify the \u003cstrong\u003eauxiliary switch\u003c\/strong\u003e wiring at terminals 2 and 3. Ensure the end switch is making continuity when the valve reaches the fully open position; if the motor cycles but the contact fails, the assembly may need replacement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow long does the 1361-102 take to cycle?\u003c\/strong\u003e\u003cbr\u003e\nStandard operation cycles are approximately 45 seconds to open and 45 to 60 seconds to close, ensuring quiet operation and preventing water hammer in the piping.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: red;\"\u003eThis item is not eligible for free shipping.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Copeland Comfort Control (White Rodgers)","offers":[{"title":"Default Title","offer_id":35650243404,"sku":"1361-102","price":233.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/products\/Pic_d9b7cb4b-e079-4444-b94a-795971e31770.png?v=1677626688","url":"https:\/\/www.gsistore.com\/products\/copeland-comfort-control-white-rodgers-1361-102-valve","provider":"GSIstore","version":"1.0","type":"link"}