{"product_id":"hankison-hprb50-a-air-dryer","title":"Hankison HPRB50-A Air Dryer","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eSPX FLOW Hankison HPRB50-A Refrigerated Air Dryer\u003c\/span\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cspan\u003e50 SCFM non-cycling compressed air dryer\u003c\/span\u003e\u003cspan\u003e designed to remove moisture from compressed air systems used in industrial facilities, maintenance shops, and pneumatic equipment applications. Operating on \u003c\/span\u003e\u003cspan\u003e115V, single-phase, 60Hz\u003c\/span\u003e\u003cspan\u003e electrical power, this unit uses a refrigeration circuit to cool compressed air, condense water vapor, and separate moisture before air enters downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eHankison HPRB50-A air dryer\u003c\/span\u003e\u003cspan\u003e delivers a nominal \u003c\/span\u003e\u003cspan\u003e50°F (10°C) pressure dew point\u003c\/span\u003e\u003cspan\u003e under specified rating conditions, helping reduce liquid water accumulation, corrosion, and moisture-related pneumatic equipment problems. Its \u003c\/span\u003e\u003cspan\u003e50 CFM compressed air drying capacity\u003c\/span\u003e\u003cspan\u003e is rated at 100 PSIG inlet pressure, 100°F inlet air temperature, and 100°F ambient temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cspan\u003eindustrial refrigerated compressed air dryer\u003c\/span\u003e\u003cspan\u003e features \u003c\/span\u003e\u003cspan\u003e1\/2-inch FNPT inlet and outlet connections\u003c\/span\u003e\u003cspan\u003e, a non-cycling refrigeration system, and R513A refrigerant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVerify compressor output, operating pressure, inlet temperature, ventilation clearance, and condensate drainage requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer:\u003c\/span\u003e\u003cspan\u003e SPX FLOW \/ Hankison.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eModel Number:\u003c\/span\u003e\u003cspan\u003e HPRB50-A.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003cspan\u003e Non-cycling refrigerated compressed air dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSeries:\u003c\/span\u003e\u003cspan\u003e Hankison HPRB.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eRated Airflow Capacity:\u003c\/span\u003e\u003cspan\u003e 50 SCFM (approximately 85 m³\/h).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectrical Supply:\u003c\/span\u003e\u003cspan\u003e 115V AC, single-phase, 60Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePower Consumption:\u003c\/span\u003e\u003cspan\u003e Approximately 0.52 kW.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eRefrigerant:\u003c\/span\u003e\u003cspan\u003e R513A.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eNominal Pressure Dew Point:\u003c\/span\u003e\u003cspan\u003e 50°F (10°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMoisture Classification:\u003c\/span\u003e\u003cspan\u003e ISO 8573-1 Class 6 pressure dew point under rated conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAir Inlet Connection:\u003c\/span\u003e\u003cspan\u003e 1\/2-inch FNPT.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAir Outlet Connection:\u003c\/span\u003e\u003cspan\u003e 1\/2-inch FNPT.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Inlet Air Pressure:\u003c\/span\u003e\u003cspan\u003e 200 PSIG.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Inlet Air Temperature:\u003c\/span\u003e\u003cspan\u003e 120°F (approximately 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMaximum Ambient Temperature:\u003c\/span\u003e\u003cspan\u003e 110°F (43°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eMinimum Ambient Temperature:\u003c\/span\u003e\u003cspan\u003e 40°F (4°C), according to current manufacturer specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eRated Operating Conditions:\u003c\/span\u003e\u003cspan\u003e 100 PSIG inlet pressure, 100°F inlet temperature, and 100°F ambient temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDryer Configuration:\u003c\/span\u003e\u003cspan\u003e Non-cycling refrigeration system for continuous compressed air treatment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCondensate Management:\u003c\/span\u003e\u003cspan\u003e Integrated moisture separation with condensate drainage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHeat Exchanger:\u003c\/span\u003e\u003cspan\u003e Combined precooling, chilling, and moisture separation design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eApproximate Dimensions:\u003c\/span\u003e\u003cspan\u003e 15.4 inches wide × 16.9 inches deep × 17.5 inches high.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eApproximate Unit Weight:\u003c\/span\u003e\u003cspan\u003e 69 lbs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePrimary Function:\u003c\/span\u003e\u003cspan\u003e Reduces moisture content in compressed air to help protect downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eTypical Applications:\u003c\/span\u003e\u003cspan\u003e Industrial air compressors, pneumatic tools, manufacturing equipment, and general compressed air distribution systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eInstallation Considerations:\u003c\/span\u003e\u003cspan\u003e Verify airflow demand, operating pressure, ambient ventilation, electrical supply, and condensate drain routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eCommon Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eQ: What size air compressor can be used with the Hankison HPRB50-A refrigerated air dryer?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The \u003c\/span\u003e\u003cspan\u003eHankison HPRB50-A\u003c\/span\u003e\u003cspan\u003e has a rated capacity of \u003c\/span\u003e\u003cspan\u003e50 SCFM\u003c\/span\u003e\u003cspan\u003e under specified conditions. Select the dryer according to the compressor's actual delivered airflow, inlet air temperature, operating pressure, and ambient temperature rather than motor horsepower alone. Applications exceeding the rated capacity may require a larger dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What dew point does the Hankison HPRB50-A air dryer provide?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The HPRB50-A is designed to maintain a nominal \u003c\/span\u003e\u003cspan\u003e50°F (10°C) pressure dew point\u003c\/span\u003e\u003cspan\u003e under rated operating conditions. This helps remove condensed moisture from compressed air and reduce water-related problems in downstream pneumatic equipment. Actual performance depends on airflow, inlet temperature, pressure, and ambient conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What are the electrical and installation requirements for the Hankison HPRB50-A?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA: The unit requires \u003c\/span\u003e\u003cspan\u003e115V AC, single-phase, 60Hz\u003c\/span\u003e\u003cspan\u003e electrical service and has \u003c\/span\u003e\u003cspan\u003e1\/2-inch FNPT air inlet and outlet connections\u003c\/span\u003e\u003cspan\u003e. Install it in a properly ventilated location with suitable condensate drainage. Confirm the equipment nameplate, circuit requirements, air piping, and manufacturer installation instructions before commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDisclaimer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eWhile we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHPRB50-A is the cross for HPR-50\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 style=\"margin-top: 0in;\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: 'Segoe UI',sans-serif; color: #ff2a00;\"\u003eThis item is not eligible for free shipping and must be shipped via trucking. Please contact us for a freight quote.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 18.0pt; font-family: 'Segoe UI',sans-serif; color: #1f2124;\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e","brand":"Hankison","offers":[{"title":"Default Title","offer_id":35657947852,"sku":"HPRB50-A","price":3470.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_074aa20f-e6e3-49aa-a8de-60e51e36eaa6.webp?v=1794598709","url":"https:\/\/www.gsistore.com\/products\/hankison-hprb50-a-air-dryer","provider":"GSIstore","version":"1.0","type":"link"}