Johnson Controls NSB8BTN140-0 Network Sensor

Johnson Controls NSB8BTN140-0 Network Sensor

  • $125.61


The Johnson Controls NSB8BTN140-0 is a high-performance NS8000 Series network sensor engineered for precise HVAC zone temperature control. This robust BACnet MS/TP compatible device serves as the direct replacement for legacy models NS-BTP7001-2, NS-BTP7002-0, and NS-ATP7002-0, ensuring a seamless upgrade path for existing Metasys system or Facility Explorer installations. Designed for professional contractors, this unit features a clear digital display and an intuitive warmer/cooler setpoint interface, allowing for efficient local adjustments while maintaining centralized oversight. Communicating over the SA Bus, the NSB8BTN140-0 integrates natively with FEC, FAC, and VMA controllers. Its surface-mount or vertical wallbox-mounted design provides flexible installation options in diverse commercial environments. By utilizing a digital temperature sensor, it delivers reliable data to the building automation system, optimizing energy efficiency and occupant comfort without the need for additional humidity or CO2 sensing in this specific configuration.

Key Benefits:
  • Direct Retrofit Compatibility: Perfectly replaces obsolete NS-BTP7001-2, NS-BTP7002-0, and NS-ATP7002-0 sensors without requiring extensive rewiring.
  • Seamless Integration: Communicates via BACnet MS/TP protocol for native recognition by Johnson Controls field controllers and Verasys smart equipment.
  • Simplified User Interface: The warmer/cooler interface provides end-users with straightforward setpoint adjustments while the backlit display shows real-time status.
  • Flexible Wiring: Supports both modular jack and screw terminal connections for fast, error-free installation on the SA Bus.
  • Code Compliance: Meets California Energy Code (Title 24) requirements for state-mandated economizer fault condition displays.
Common Questions:
  • Is this sensor compatible with non-Johnson Controls systems? While designed for Metasys and Facility Explorer via BACnet MS/TP, it is optimized for the SA Bus architecture found in Johnson Controls and Smart Equipment controllers.
  • How do I address the sensor on the bus? Addressing is typically handled via DIP switches or the display interface, allowing multiple sensors to reside on the same SA Bus segment.
  • Can this model monitor relative humidity? No, the NSB8BTN140-0 is a temperature-only model. If RH or CO2 monitoring is required, an alternative NS8000 series model should be selected.