{"product_id":"weil-mclain-633-600-012","title":"Weil McLain 633-600-012 Service Pack","description":"\u003cp\u003eThe \u003cstrong\u003eWeil McLain 633-600-012 AcuTemp 2000WM Service Pack\u003c\/strong\u003e is the \u003cstrong\u003eOEM\u003c\/strong\u003e service kit for the \u003cstrong\u003eAcuTemp\u003c\/strong\u003e \u003cstrong\u003etemperature control\u003c\/strong\u003e used on \u003cstrong\u003eWeil-McLain\u003c\/strong\u003e \u003cstrong\u003eAqua Plus\u003c\/strong\u003e and \u003cstrong\u003eAqua Pro\u003c\/strong\u003e \u003cstrong\u003eindirect water heaters\u003c\/strong\u003e. The control mounts on the top \u003cstrong\u003eplastic cap\u003c\/strong\u003e of the tank, reads the tank through a \u003cstrong\u003esensor\u003c\/strong\u003e and tells the boiler or \u003cstrong\u003ezone control\u003c\/strong\u003e when the tank needs heat by closing a set of \u003cstrong\u003eisolated dry contacts\u003c\/strong\u003e on the \u003cstrong\u003edomestic water input\u003c\/strong\u003e. A built-in \u003cstrong\u003emicrocontroller\u003c\/strong\u003e watches how fast the \u003cstrong\u003etank temperature\u003c\/strong\u003e is changing and decides when to start a heat call, which cuts down \u003cstrong\u003etemperature swings\u003c\/strong\u003e and improves \u003cstrong\u003efuel efficiency\u003c\/strong\u003e compared with a plain aquastat. Weil-McLain also supplies the \u003cstrong\u003eAcuTemp 2000WM\u003c\/strong\u003e control without a sensor as the \u003cstrong\u003e633-600-011\u003c\/strong\u003e, so match the number to what the tank actually needs.\u003c\/p\u003e\n\n\u003cp\u003eElectrically the \u003cstrong\u003eAcuTemp\u003c\/strong\u003e is simple. It needs a field-supplied \u003cstrong\u003e24 VAC\u003c\/strong\u003e transformer, draws \u003cstrong\u003e2.4 VA\u003c\/strong\u003e at \u003cstrong\u003e60 Hz\u003c\/strong\u003e, and switches \u003cstrong\u003eisolated dry contacts\u003c\/strong\u003e rated \u003cstrong\u003e50 VA\u003c\/strong\u003e at \u003cstrong\u003e24 VAC\u003c\/strong\u003e that land on the \u003cstrong\u003edomestic water input\u003c\/strong\u003e of the zone or boiler control. To keep \u003cstrong\u003estray voltage\u003c\/strong\u003e off the sensor circuit, \u003cstrong\u003e24 VAC\u003c\/strong\u003e goes to \u003cstrong\u003eAC2\u003c\/strong\u003e and \u003cstrong\u003eAC1\u003c\/strong\u003e is grounded, and you should read \u003cstrong\u003e24 VAC\u003c\/strong\u003e between \u003cstrong\u003eAC1\u003c\/strong\u003e and \u003cstrong\u003eAC2\u003c\/strong\u003e before blaming the control. Settings are made at the dial: press it once and the display shows \u003cstrong\u003eOFF\u003c\/strong\u003e or the current setpoint, turn it to change the value, and after \u003cstrong\u003efive\u003c\/strong\u003e seconds without input it drops back to operating mode. Two ranges are built in, a residential range of \u003cstrong\u003e60°F\u003c\/strong\u003e to \u003cstrong\u003e160°F\u003c\/strong\u003e and a commercial range of \u003cstrong\u003e60°F\u003c\/strong\u003e to \u003cstrong\u003e180°F\u003c\/strong\u003e, and the \u003cstrong\u003eFahrenheit\u003c\/strong\u003e or \u003cstrong\u003eCelsius\u003c\/strong\u003e display is chosen by holding the dial for \u003cstrong\u003efive\u003c\/strong\u003e seconds. A light at the bottom right of the display shows a call for heat and a light on the left shows \u003cstrong\u003estandby\u003c\/strong\u003e once the tank reaches setpoint. The differential never needs adjusting because the control's own algorithm decides when to start a heat call.\u003c\/p\u003e\n\n\u003cp\u003eInstallation follows the tank. On a new installation, find the sensor leads on top of the tank, run the \u003cstrong\u003esensor wire\u003c\/strong\u003e through the opening in the back of the control, plug it into the \u003cstrong\u003esensor input\u003c\/strong\u003e (polarity does not matter), seat the wire in the channel on the back, and fasten the control to the \u003cstrong\u003eplastic cap\u003c\/strong\u003e with two screws plus a third through the top before the cover goes back on. When replacing an \u003cstrong\u003eAqua Plus\u003c\/strong\u003e control, remove the faceplate, the old thermostat and the old sensor, disconnect the \u003cstrong\u003edomestic water input\u003c\/strong\u003e wires, insert the new sensor, pass both wires through the faceplate hole and remount with three screws. Weil-McLain publishes wiring diagrams for \u003cstrong\u003eAquaBalance\u003c\/strong\u003e controls and for the \u003cstrong\u003eECO\u003c\/strong\u003e, \u003cstrong\u003eEvergreen\u003c\/strong\u003e, \u003cstrong\u003eSlimfit\u003c\/strong\u003e, \u003cstrong\u003eUltra\u003c\/strong\u003e, \u003cstrong\u003eGV90+\u003c\/strong\u003e, \u003cstrong\u003eCGa\u003c\/strong\u003e, \u003cstrong\u003eCGi\u003c\/strong\u003e, \u003cstrong\u003eEG\u003c\/strong\u003e water and \u003cstrong\u003eWM97+\u003c\/strong\u003e boiler lines. The displayed temperature is approximate because a tank always has temperature variation inside it, so start near \u003cstrong\u003e120°F\u003c\/strong\u003e and finish the adjustment by testing water at the closest point of use. Water at \u003cstrong\u003e125°F\u003c\/strong\u003e or hotter can scald, and a \u003cstrong\u003emixing valve\u003c\/strong\u003e is recommended wherever point-of-use water reaches that level. A \u003cstrong\u003eSensor Error\u003c\/strong\u003e means the sensor resistance is out of range, so check the connection at the circuit board and replace the sensor if the connection is good. A \u003cstrong\u003eSelf Test Error\u003c\/strong\u003e means an internal check failed, so cycle the \u003cstrong\u003e24 VAC\u003c\/strong\u003e power off and on and replace the control if the error stays.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSmarter Heat Calls:\u003c\/strong\u003e The \u003cstrong\u003emicrocontroller\u003c\/strong\u003e tracks how fast the \u003cstrong\u003etank temperature\u003c\/strong\u003e moves and starts \u003cstrong\u003eheat calls\u003c\/strong\u003e to reduce swings and save \u003cstrong\u003efuel\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBuilt For Weil-McLain Tanks:\u003c\/strong\u003e Made for \u003cstrong\u003eAqua Plus\u003c\/strong\u003e and \u003cstrong\u003eAqua Pro\u003c\/strong\u003e \u003cstrong\u003eindirect water heaters\u003c\/strong\u003e and documented with wiring for the \u003cstrong\u003eECO\u003c\/strong\u003e, \u003cstrong\u003eUltra\u003c\/strong\u003e, \u003cstrong\u003eGV90+\u003c\/strong\u003e, \u003cstrong\u003eWM97+\u003c\/strong\u003e and other \u003cstrong\u003eWeil-McLain\u003c\/strong\u003e boiler lines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEasy Field Setup:\u003c\/strong\u003e One \u003cstrong\u003epush dial\u003c\/strong\u003e sets temperature, switches \u003cstrong\u003eFahrenheit\u003c\/strong\u003e and \u003cstrong\u003eCelsius\u003c\/strong\u003e and selects the \u003cstrong\u003eresidential\u003c\/strong\u003e or \u003cstrong\u003ecommercial\u003c\/strong\u003e range.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eClear Diagnostics:\u003c\/strong\u003e \u003cstrong\u003eSensor Error\u003c\/strong\u003e and \u003cstrong\u003eSelf Test Error\u003c\/strong\u003e messages plus the \u003cstrong\u003ecall for heat\u003c\/strong\u003e and \u003cstrong\u003estandby\u003c\/strong\u003e lights make troubleshooting quick.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhich water heaters does it fit?\u003c\/strong\u003e It is the \u003cstrong\u003eAcuTemp\u003c\/strong\u003e control for \u003cstrong\u003eWeil-McLain\u003c\/strong\u003e \u003cstrong\u003eAqua Plus\u003c\/strong\u003e and \u003cstrong\u003eAqua Pro\u003c\/strong\u003e \u003cstrong\u003eindirect water heaters\u003c\/strong\u003e. Check the control already on the tank before ordering.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat power does it need?\u003c\/strong\u003e A field-supplied \u003cstrong\u003e24 VAC\u003c\/strong\u003e transformer. The control draws \u003cstrong\u003e2.4 VA\u003c\/strong\u003e and its \u003cstrong\u003edry contacts\u003c\/strong\u003e are rated \u003cstrong\u003e50 VA\u003c\/strong\u003e at \u003cstrong\u003e24 VAC\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat temperature should I set?\u003c\/strong\u003e Start near \u003cstrong\u003e120°F\u003c\/strong\u003e, then test at the point of use. Use a \u003cstrong\u003emixing valve\u003c\/strong\u003e if the water reaches \u003cstrong\u003e125°F\u003c\/strong\u003e or more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"Weil McLain","offers":[{"title":"Default Title","offer_id":68120326701234,"sku":"633-600-012","price":129.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/633-600-012.jpg?v=1795307911","url":"https:\/\/www.gsistore.com\/products\/weil-mclain-633-600-012","provider":"GSIstore","version":"1.0","type":"link"}