{"product_id":"york-013-04128-000","title":"York 013-04128-000 Corrosion Inhibitor","description":"\u003cp\u003eThe \u003cstrong\u003eYork 013-04128-000 Solid State Starter and VSD Coolant Inhibitor\u003c\/strong\u003e is the factory-specified, \u003cstrong\u003epremixed coolant\u003c\/strong\u003e for \u003cstrong\u003eYork liquid-cooled solid state starters (SSS)\u003c\/strong\u003e and \u003cstrong\u003eliquid-cooled variable speed drives (VSD)\u003c\/strong\u003e on \u003cstrong\u003eYork centrifugal chillers\u003c\/strong\u003e. This \u003cstrong\u003e5-gallon\u003c\/strong\u003e container is marked \u003cstrong\u003epremixed, do not dilute\u003c\/strong\u003e, so it goes into the \u003cstrong\u003edrive coolant loop\u003c\/strong\u003e exactly as supplied, with no water, glycol, or additive mixed in. The \u003cstrong\u003e013-04128-000\u003c\/strong\u003e is the current 5-gallon size and \u003cstrong\u003esupersedes the earlier 5-gallon number 013-03908-000\u003c\/strong\u003e. York offers the same drive coolant in a \u003cstrong\u003e1-gallon container (013-04129-000)\u003c\/strong\u003e, which replaced the original \u003cstrong\u003e1-gallon inhibitor 013-02987-000\u003c\/strong\u003e, and in a \u003cstrong\u003e55-gallon drum (013-04127-000)\u003c\/strong\u003e, so the container can be matched to the size of the service job.\u003c\/p\u003e\n\n\u003cp\u003eA liquid-cooled drive moves the heat of its power electronics out of the cabinet with a closed \u003cstrong\u003ecoolant loop\u003c\/strong\u003e. On York liquid-cooled variable speed drives that loop is built from \u003cstrong\u003ecoolant pumps\u003c\/strong\u003e, an \u003cstrong\u003einternal cooling coil\u003c\/strong\u003e, a \u003cstrong\u003ecoolant header with a fill plug\u003c\/strong\u003e, a \u003cstrong\u003eplate heat exchanger\u003c\/strong\u003e, and a \u003cstrong\u003e1.5-inch Y-strainer (029-21798-000)\u003c\/strong\u003e, joined by hoses and clear tubing. The fluid in that loop works continuously at temperature, so its \u003cstrong\u003ecorrosion inhibitor\u003c\/strong\u003e package is what protects the coil, pumps, and heat exchanger from corrosion and fouling. York's own parts catalog lists its drive coolant under the \u003cstrong\u003epreventive-maintenance kit for YK, YS, and YT chillers (all series)\u003c\/strong\u003e and calls for \u003cstrong\u003e1 gallon for a solid state starter\u003c\/strong\u003e and \u003cstrong\u003e3 gallons for a VSD\u003c\/strong\u003e. The same catalog states that the coolant \u003cstrong\u003emust be changed annually\u003c\/strong\u003e, or sooner if it has become \u003cstrong\u003ecloudy or brown\u003c\/strong\u003e, and that coolant should \u003cstrong\u003enever be reused\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eLook at the coolant every time the drive is opened for service. \u003cstrong\u003eClear fluid\u003c\/strong\u003e at the correct level is normal; \u003cstrong\u003ecloudy or brown coolant\u003c\/strong\u003e, a falling level, or any leak at the hoses, the \u003cstrong\u003ecoolant header\u003c\/strong\u003e, or the \u003cstrong\u003efill plug\u003c\/strong\u003e means the loop needs attention before the drive overheats. To change it, \u003cstrong\u003elock out and discharge the drive\u003c\/strong\u003e as York's service manual directs, drain the old coolant completely, inspect the \u003cstrong\u003eY-strainer 029-21798-000\u003c\/strong\u003e and the hoses, refill through the \u003cstrong\u003efill plug\u003c\/strong\u003e with \u003cstrong\u003e013-04128-000\u003c\/strong\u003e, bleed air from the loop as the manual describes, and run the \u003cstrong\u003ecoolant pumps\u003c\/strong\u003e while rechecking the level. Do not mix this coolant with other fluids or dilute it, keep the container sealed and labeled, and read the \u003cstrong\u003esafety data sheet\u003c\/strong\u003e and wear \u003cstrong\u003egloves and eye protection\u003c\/strong\u003e when handling it. Dispose of drained coolant according to local regulations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFactory-Specified Coolant:\u003c\/strong\u003e The coolant York specifies for its \u003cstrong\u003eliquid-cooled SSS and VSD\u003c\/strong\u003e drives, not a generic substitute, so the loop is filled with the fluid the drive was designed around.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePremixed, Ready To Pour:\u003c\/strong\u003e Marked \u003cstrong\u003epremixed, do not dilute\u003c\/strong\u003e, so there is no mixing ratio to get wrong in the field.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCorrosion Protection For The Loop:\u003c\/strong\u003e Supplied as an \u003cstrong\u003einhibited coolant\u003c\/strong\u003e to protect the \u003cstrong\u003ecooling coil, pumps, and plate heat exchanger\u003c\/strong\u003e through the annual change interval.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e5-Gallon Service Size:\u003c\/strong\u003e Enough for a \u003cstrong\u003e3-gallon VSD change\u003c\/strong\u003e or a \u003cstrong\u003e1-gallon starter change\u003c\/strong\u003e with fluid left to top off; York also makes \u003cstrong\u003e1-gallon (013-04129-000)\u003c\/strong\u003e and \u003cstrong\u003e55-gallon (013-04127-000)\u003c\/strong\u003e sizes for other jobs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWhat equipment does it go into?\u003c\/strong\u003e York liquid-cooled \u003cstrong\u003esolid state starters\u003c\/strong\u003e and \u003cstrong\u003evariable speed drives\u003c\/strong\u003e on York centrifugal chillers, listed by York under the \u003cstrong\u003eYK, YS, and YT\u003c\/strong\u003e preventive-maintenance kit. Confirm the coolant your drive uses from its service manual or data label.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDo I mix it with water or glycol?\u003c\/strong\u003e No. The container is marked \u003cstrong\u003epremixed, do not dilute\u003c\/strong\u003e; pour it as supplied.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHow often should it be changed?\u003c\/strong\u003e York's guidance is \u003cstrong\u003eannually\u003c\/strong\u003e, or sooner if the coolant turns \u003cstrong\u003ecloudy or brown\u003c\/strong\u003e, and drained coolant should \u003cstrong\u003enever be reused\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":67694982135986,"sku":"013-04128-000","price":1057.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/013-04128-000.jpg?v=1791918784","url":"https:\/\/www.gsistore.com\/products\/york-013-04128-000","provider":"GSIstore","version":"1.0","type":"link"}