{"product_id":"york-325-28678-700-pressure-transducer-kit","title":"York 325-28678-700 Pressure Transducer Kit","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eYork Applied 325-28678-700 pressure transducer kit\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e is a replacement HVACR component designed for compatible York commercial air conditioning and refrigeration equipment. The transducer monitors system pressure and converts pressure measurements into an electrical signal used by the equipment’s control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for professional HVACR maintenance and repair, this \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eYork pressure sensor kit\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e supports accurate pressure monitoring, equipment diagnostics, and system control. Reliable pressure feedback allows the controller to monitor operating conditions and respond to abnormal system pressures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eYork 325-28678-700 replacement pressure transducer\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e is suitable for servicing compatible equipment experiencing inaccurate pressure readings, faulty sensor signals, or pressure-related alarms. Before installation, technicians should verify the equipment model, serial number, operating pressure range, supply voltage, wiring configuration, and pressure connection. Proper installation of this \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eHVAC pressure transducer kit\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e helps restore reliable pressure monitoring and dependable equipment operation while minimizing unnecessary replacement of other control components.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cp\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eYork Applied \/ Johnson Controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e325-28678-700\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eAlternate Part Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e32528678700\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePressure transducer kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003ePressure sensing and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eElectrical pressure feedback\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eCommercial HVACR equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eEquipment Compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003eSelect York Applied systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eYork replacement component:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Designed for compatible York Applied HVAC equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccurate pressure monitoring:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Supports reliable system pressure measurement and control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEquipment protection:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Helps controllers detect abnormal operating pressures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable electrical feedback:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Converts measured pressure into an electrical signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eImproved system diagnostics:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Assists technicians in troubleshooting pressure-related faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommercial HVACR application:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Suitable for maintenance and repair of compatible equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReplacement kit configuration:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Facilitates professional pressure transducer replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is the purpose of the York 325-28678-700 pressure transducer kit?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt provides pressure feedback to the HVAC control system, supporting equipment monitoring, diagnostics, and operating control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat are the symptoms of a faulty pressure transducer?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCommon symptoms include inaccurate pressure readings, erratic sensor signals, pressure-related alarms, unexpected equipment shutdowns, and inconsistent system operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs the York 325-28678-700 compatible with all York chillers?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNo. Compatibility depends on the equipment model, serial number, pressure range, electrical requirements, and sensor configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat should technicians check before replacing a pressure transducer?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTechnicians should inspect the supply voltage, sensor wiring, electrical connections, actual system pressure, and controller input readings. Comparing sensor readings against a calibrated pressure gauge helps identify defective components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e325-28678-700 is the cross for \u003c\/span\u003e025-28678-104, 025-28678-005\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":35656832588,"sku":"325-28678-700","price":1206.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1838\/2375\/files\/ac-parts-1000x1000_36b0d568-7096-4aed-88a7-b1d354fee8f0.webp?v=1795489888","url":"https:\/\/www.gsistore.com\/products\/york-325-28678-700-pressure-transducer-kit","provider":"GSIstore","version":"1.0","type":"link"}