Heil Quaker ICP 1054372 Sequencer

Heil Quaker ICP 1054372 Sequencer

Heil Quaker ICP

  • $59.00


The Heil Quaker ICP 1054372 Sequencer is a critical SPDT 24V time-delay control designed for staging electric heating elements and blower motors in International Comfort Products residential and light commercial equipment. Built for high-frequency cycling, this electric heat sequencer prevents simultaneous high-amperage draws that lead to tripped breakers by staggering the activation of auxiliary heat strips and fan circuits. This HVAC sequencer 1054372 features a robust bimetal heater and Single Pole Double Throw configuration, ensuring precise timing on both the "on" and "off" cycles. It is a direct fit for numerous Heil Quaker, Comfortmaker, and Tempstar air handlers and packaged units, maintaining original performance specifications. When troubleshooting furnace sequencer clicking or failures where heating elements stay energized, this OEM-spec component provides the reliability required for 24VAC control systems in multi-stage heating applications. Key Benefits for Technicians
  • Staged Element Activation: Prevents electrical surges by sequencing heat elements and the blower motor.
  • OEM Compatibility: Exact replacement for ICP 1054372, fitting models like APK036K000A and A2P030B3Y1.
  • Universal 24V Operation: Compatible with standard 24VAC HVAC control transformers and thermostats.
  • SPDT Logic: Allows for integrated fan control and heating stage management in a single compact footprint.
  • Durable Bimetal Construction: Designed to withstand the thermal stress of modern electric furnace operation.
Common Questions for HVAC Professionals How do I test the ICP 1054372 sequencer using a multimeter? Set your multimeter to the Volts AC scale. Check for 24V at the bottom heater terminals (usually labeled H1/H2). If voltage is present but the sequencer contacts do not close after the rated time delay (typically 1?20 seconds for the first stage), the internal bimetal heater has failed. Does this sequencer control the blower motor? Yes, the SPDT 24V configuration is frequently utilized to trigger the indoor blower motor simultaneously with the first bank of heating elements to ensure proper airflow and prevent high-limit tripping. Can I use this to replace a different sequencer brand? As long as the voltage (24V), pole configuration (SPDT), and timing specifications align, this unit functions as a high-quality replacement. However, always refer to the specific Heil Quaker wiring diagram for terminal mapping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • Do you carry model number FEM4P3600AL5E

    Please reply us your email address so we can send you the parts breakdown list for this model. Thanks