The Warrick 16C1A01414 is a professional-grade conductivity-based liquid level control designed for heavy-duty HVACR and industrial applications. This 120Vac supply voltage unit features a 26,000 ohm sensitivity, making it ideal for monitoring condensate, boiler water, or other conductive fluids where precision is non-negotiable. Engineered for reliability, this direct acting control utilizes a SPDT relay (1 Normally Open/1 Normally Closed) to manage pump or valve operations seamlessly. A critical technical advantage of the 16C1A01414 is its integrated 14-second time delay on both increasing and decreasing levels, which effectively prevents equipment short-cycling and nuisance trips caused by turbulent liquid surfaces or "sloshing." The open circuit board design with spade terminals and a 1/16" panel standoff allows for efficient mounting within custom enclosures. For technicians performing a Warrick 16C series replacement, this dual time delay level control ensures stable system performance in demanding environments.

Key Benefits
  • Anti-Short Cycle Protection: The dual 14-second time delay relay filters out momentary level fluctuations, extending the life of pumps and contactors.
  • High Conductivity Sensitivity: The 26k ohm direct acting configuration is optimized for standard water and condensate applications.
  • Flexible Integration: features a SPDT (Form C) relay for versatile NO/NC wiring logic to meet various fail-safe requirements.
  • Compact Form Factor: The open board level control with 1/16" standoffs fits into small panels where space is at a premium.
  • Robust Field Wiring: Standard 3/16" spade terminals provide secure, vibration-resistant electrical connections for field service.
Common Questions

How does the 14-second time delay affect system operation?
The delay requires the liquid to maintain contact with the probe (or remain below it) for a continuous 14 seconds before the SPDT relay flips. This prevents the system from "chattering" during rapid surface movement.

Can the Warrick 16C1A01414 be used as a low water cutoff?
Yes, in direct acting mode, it is frequently utilized for low water cutoff and alarm functions in boiler and cooling tower loops.

What is the maximum ambient temperature for this control board?
This general purpose open control is rated for operation in ambient environments ranging from -40°F to +150°F.