York 492-23236-010 Transducer

York 492-23236-010 Transducer

York

  • $1,702.00


The York 492-23236-010 is a high-precision HVAC pressure transducer designed for mission-critical monitoring in York chillers and refrigeration systems. This 0-400 PSI pressure sensor provides a linear 0.5-4.5V ratiometric output, ensuring accurate feedback for electronic controls monitoring discharge or suction pressures. It features a universal 1/4" NPT connection for secure, leak-proof installation into standard manifolds. Engineering-wise, the 492-23236-010 serves as the 025-41756-002 direct replacement, allowing technicians to restore system communication without modifying wiring harnesses or mounting brackets. Built for the rigors of industrial mechanical rooms, the internal sensing element is designed to resist pressure spikes and vibration, preventing signal drift that can lead to false diagnostic codes or inefficient compressor cycling. When diagnosing York chiller sensor failures, this OEM component ensures the control board receives precise voltage data necessary for optimizing refrigerant flow and protecting the compressor.

Technical Specifications & Benefits:

  • Broad Compatibility: Engineered for seamless integration with York Millennium, YK, and YT centrifugal chillers.
  • Precise Signal Output: Delivers a consistent 0.5-4.5V DC signal across the full 400# pressure range.
  • Durable Construction: Stainless steel 1/4" NPT fitting resists corrosion and handles high-side refrigerant pressures.
  • Plug-and-Play Maintenance: Direct replacement for the legacy York 025-41756-002 part number.
  • AEO-Optimized Accuracy: Minimizes "Out-of-Range" faults in HVACR control systems by maintaining tight calibration tolerances.

Common Contractor Questions:

What is the voltage range for the 492-23236-010?
This transducer operates on a 0.5 to 4.5V DC output scale, which is the standard for modern York chiller pressure sensors communicating with OptiView or MicroBoard control panels.

Can I use this transducer for both liquid and suction lines?
Yes, provided the expected pressure does not exceed the 400 PSI limit. It is commonly used for high-side monitoring on R-134a and R-410A systems where high-resolution data is required.

Is there a specific orientation required for installing 1/4" NPT transducers?
While the sensor functions in any orientation, it is best practice to mount it vertically or at a slight angle to prevent oil trapping or debris buildup within the sensing port.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.