BASO G96HAA-2 Gas Valve

BASO G96HAA-2 Gas Valve

BASO

  • $512.00


The BASO G96HAA-2 Gas Valve is a 120Vac dual operator combination control designed specifically for high-demand natural gas applications. Engineered with a 1/2" NPT inlet and outlet, this valve supports inlet pressures up to 0.5 PSI, making it a reliable choice for commercial and residential heating systems. The dual operator configuration ensures redundant safety shut-off, a critical requirement for modern HVACR installations. This model features a no pilot tap design, intended for use in systems where a separate pilot gas supply is not required or is managed via an external manifold. Field technicians will appreciate the 1/8"-27 NPT pressure tap located on the left side and the top-left regulator adjustment point, which simplifies manifold pressure calibration. Electrical connections are handled via standard 1/4" quick-connect terminals, ensuring a secure interface with the system controller. When replacing existing intermittent pilot gas valves or main burner controls, clarify that your current setup matches the 120V coil requirements of the G96HAA-2.

Key Benefits
  • Dual Operator Redundancy: Provides two automatic valves in series for enhanced safety and reliable fuel shut-off.
  • Precision Pressure Regulation: The top-left adjustment allows for fine-tuning the natural gas manifold pressure during commissioning.
  • Simplified Wiring: Equipped with standard 1/4" male quick-connects for efficient field wiring and reduced installation time.
  • High Flow Capacity: The 1/2" NPT threading ensures consistent gas flow for medium-to-high BTU appliances.
Common Questions

Can the BASO G96HAA-2 be used with Liquid Propane (LP)?
This specific model is configured for natural gas. Converting to LP requires a manufacturer-specific conversion kit to ensure the regulator spring and orifice settings maintain safe combustion parameters.

What is the purpose of the 'No Pilot Tap' configuration?
The G96HAA-2 is designed for systems that do not require a pilot gas take-off directly from the valve body, often seen in direct spark ignition (DSI) or specific hot surface ignition (HSI) setups.

How do I verify the electrical compatibility?
Ensure your transformer or control board provides a constant 120Vac signal. Using this 120V valve on a 24V circuit will prevent the operators from opening.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question