BASO H15CA-1 Gas Valve

BASO H15CA-1 Gas Valve

BASO

  • $419.00


The BASO H15CA-1 Gas Valve is an essential automatic shut-off pilot gas valve designed for mission-critical reliability in commercial cooking equipment and industrial heating applications. This pilot safety valve utilizes a 1/2" NPT inlet and outlet configuration with an internal pilot gas flow path, specifically engineered without a Rotor B valve. It is rated for a maximum pressure of 0.5 PSI, supporting both natural gas and liquid propane (LP) systems. The technical architecture includes a 1/8"-27 NPT pilot tap positioned over the inlet for streamlined installation and pilot line integration. As a direct drop-in for the H15CA-1C, this unit provides high-flow capacity in a compact footprint, ensuring consistent thermal safety and fuel shut-off performance. Technicians should note the absence of an external pressure tap, requiring upstream or downstream testing ports for manifold calibration. This robust BASO pilot gas valve remains the industry standard for maintaining flame safety protocols in high-demand environments.

Key Benefits for Technicians
  • Universal Compatibility: Fully interchangeable with H15CA-1C models, ensuring seamless field replacement in existing HVACR and kitchen lineups.
  • Dual Fuel Performance: Engineered for natural gas and LP gas valves applications up to 0.5 PSI without requiring internal modifications.
  • Simplified Pilot Routing: Features an integrated 1/8"-27 NPT pilot tap located over the inlet for efficient pilot line connections.
  • Internal Flow Design: Utilizes an internal pilot gas flow mechanism without a Rotor B valve, minimizing external leak points and mechanical failure.
  • Contractor-Grade Durability: Constructed with heavy-duty materials to withstand the high ambient temperatures found in commercial galleys and furnace rooms.
Common Questions & Technical Support

Is this BASO H15CA-1 valve compatible with both Natural Gas and Propane?
Yes, the valve is rated for both fuel types up to 0.5 PSI. Ensure your orifice and pilot burner are properly sized for the specific gas being utilized.

What is the difference between the H15CA-1 and the H15CA-1C?
These models are technically identical in performance and footprint; the "C" suffix typically denotes bulk packaging for OEMs, but the valves are functionally equivalent.

Does this unit have a pressure tap for checking manifold pressure?
No, the H15CA-1 is designed without a pressure tap. System pressure should be verified at the regulator or an alternative port in the gas train.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.