BASO T36A1-1H Thermopile

BASO T36A1-1H Thermopile

BASO

  • $68.00


The BASO T36A1-1H Thermopile is a high-performance 36-inch millivolt generator engineered for consistent voltage output in standing pilot systems. Delivering an open-circuit range of 600-750mV, this universal thermopile kit ensures the reliable operation of self-powered gas valves in residential and commercial HVACR equipment. The T36A1-1H serves as a high-durability direct replacement for Honeywell Q313A1188 and the G01A-502, providing technicians with a versatile solution for pilot burner assemblies including the Q314, Q324, and Q382 series. Its spade terminal connections facilitate a secure, low-resistance interface with millivolt gas control valves, while the corrosion-resistant fiberglass lead wires are built to withstand high-temperature environments. This kit includes the necessary PG9 adapter and push-in clip, allowing for seamless integration into various OEM pilot burner brackets across furnaces, boilers, and water heaters. For reliable flame detection and combustion safety, this thermopile generator is a standard choice for veterans in the field.

Key Benefits:
  • High Output Performance: Specifically tuned for 600-750 millivolt systems to ensure positive gas valve engagement.
  • Universal Compatibility: Includes standardized adapter kit components for rapid installation across multiple pilot burner brands.
  • Industrial-Grade Lead: The 36-inch lead length provides ample reach for large-scale furnace and boiler applications.
  • Secure Connectivity: Integrated spade terminals reduce voltage drops, maintaining millivolt system integrity.
  • Rugged Construction: Designed with corrosion-resistant sensing junctions for extended service life in harsh industrial environments.
Common Questions:

Is the T36A1-1H compatible with natural gas and propane systems?
Yes, this thermopile is engineered to operate effectively with both natural gas (NG) and liquid propane (LP) pilot flames without degradation of the sensing junction.

Will this replace a standard 30mV thermocouple?
No. This is a powerpile generator designed for 750mV circuits. It is not interchangeable with standard 30mV thermocouples used in safety-only circuits.

What is the proper millivolt reading under load?
While the open circuit output is 600-750mV, you should typically see at least 250-350mV under load at the gas valve terminals to ensure the main burner solenoid stays engaged.