The Conbraco 10-614-34 (Apollo RVW61) is an ASME Section IV certified high-capacity hot water pressure relief valve designed specifically for heavy-duty protection of hydronic heating boilers and storage systems. Featuring a rugged bronze body construction and 150 PSI factor set pressure, this 3/4" FNPT inlet x 1" FNPT outlet valve is engineered to handle massive thermal loads with a 3,655,000 BTU/hr capacity. To ensure long-term reliability in aggressive water conditions, it utilizes a silicone seat and a fabric-reinforced molded diaphragm that effectively isolates the spring from the media. The expanded 1-inch outlet reduces backpressure during discharge, while the elevated seat design ensures proper drainage of water away from the sealing surface. This industrial-grade safety valve maintains an HV rating and is the standard choice for contractors needing a high-capacity relief valve that prevents over-pressurization due to control failure or runaway BTU input.

Key Benefits
  • Maximum BTU Throughput: Rated for up to 3,655,000 BTU/hr, making it suitable for large commercial boilers and high-demand hydronic systems.
  • Durable Bronze Internals: The corrosion-resistant bronze spring cage and body ensure structural integrity under consistent 250°F maximum operating temperatures.
  • Advanced Diaphragm Protection: The fabric-reinforced diaphragm prevents mineral buildup and water contact with the spring, extending the service life of the Apollo 10-614-34.
  • ASME Section IV Compliance: National Board capacity certified to meet strict safety codes for hot water heating equipment.
Common Questions

What is the difference between the inlet and outlet sizes?
This valve features an expanded outlet—a 3/4 inch inlet and a 1 inch outlet. This design facilitates greater discharge flow and reduces the risk of backpressure, which is critical for high-capacity pressure relief applications.

Is this valve suitable for steam applications?
No, the 10-614-34 is built for hot water heating boilers and supply systems. It is not rated for steam service; for steam applications, an ASME Section I or VIII valve should be selected based on the system's specific requirements.

Can the pressure setting be adjusted in the field?
This is a factory-set 150 PSI relief valve. Field adjustments are not recommended as they can void the ASME certification and compromise the safety of the boiler system.