Field Controls 094021A0205 Probe Assembly

Field Controls 094021A0205 Probe Assembly

  • $143.00


The Field Controls 094021A0205 Probe Assembly is a critical NTC thermistor sensor engineered specifically for the Field Controls Model 2002 Steam Humidifier. Designed to monitor water temperature within the canister, this replacement humidity sensor ensures the control board receives precise resistance readings to regulate the heating cycle and prevent dry-fire conditions. The assembly features a high-grade stainless steel probe housing to resist calcification and corrosion in high-mineral water environments. Proper installation of this Field Controls humidifier part is essential for maintaining optimal steam output and ensuring the humidifier's safety logic functions correctly. This HVAC thermistor assembly utilizes a 2-wire lead configuration for direct integration with the existing Model 2002 control board. When troubleshooting a humidifier not heating or a service light error, verifying the resistance values of this probe is a standard diagnostic step for contractors maintaining residential steam systems.

Key Benefits for Field Controls 094021A0205
  • Precise Thermal Monitoring: High-accuracy NTC thermistor provides real-time temperature feedback to the humidifier control module.
  • Corrosion Resistance: The thermistor probe is constructed to withstand the aggressive environment of boiling water and scale buildup.
  • OEM Compatibility: Precision-fit Field Controls 094021A0205 ensures a leak-proof seal and correct depth within the steam canister.
  • Improved System Efficiency: Accurate sensing prevents unnecessary energy consumption by optimizing the steam production cycle.
Common Questions

How do I test if the Field Controls 094021A0205 thermistor is faulty?
Disconnect the probe from the control board and use a multimeter to check the resistance (ohms). Compare the reading against the manufacturer's resistance chart based on the current water temperature; an open circuit or "infinite" reading typically indicates a failed sensor.

Can this probe be used in the Field Controls S2000 or S2020 models?
No, this specific assembly is designed for the Model 2002 steam humidifier. Always check the harness connector and probe length before attempting installation on different series.

What causes these humidifier probes to fail prematurely?
The most common failures result from heavy mineral deposits (limescale) insulating the probe or moisture wicking into the wire leads, which skews the resistance signal sent to the controller.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question