Maintaining reliable flame rectification in Direct Spark Ignition (DSI) systems requires high-integrity components like the Heil Quaker ICP 1380667 Electrode/Sensor. As an OEM Fenwal DSI electrode, this part is engineered for precise flame sensing and ignition cycles in International Comfort Products (ICP) residential heating units. In the field, a common failure point for furnaces and power gas conversion burners is a fouled or cracked ceramic insulator on the HVAC flame sensor, which leads to nuisance lockouts and "no heat" calls. This 1380667 electrode assembly provides a direct replacement to restore the microamp signal required by the 120V or 24V ignitor control module, ensuring the gas valve remains energized after the trial for ignition.

Replacing an aging ICP furnace ignitor sensor with this genuine Fenwal 1380667 component ensures compatibility with Heil Quaker, Tempstar, and Arcoaire models. When troubleshooting, verify that the flame rectification signal is at the manufacturer's specified level to prevent soft-lockout cycles. This electrode is a critical HVAC replacement part designed to withstand high-temperature combustion environments while providing a consistent spark gap and accurate flame feedback.

  • OEM Compatibility: Exact Heil Quaker ICP 1380667 replacement for seamless fitment in ICP-branded furnaces.
  • Durable Fenwal Construction: High-grade ceramic insulation prevents voltage leakage and ensures consistent spark ignition.
  • Optimized Flame Detection: Maintains the necessary microamp signal to prevent premature DSI control module lockouts.
  • Contractor Grade: Designed for rapid field installation to reduce labor time during HVAC sensor maintenance.

Common Questions

What causes a DSI system to go into lockout?
Lockouts typically occur if the DSI electrode/sensor fails to detect a flame within the designated trial for ignition (TFI) period. This is often caused by carbon buildup on the flame sensor or a cracked insulator.

Can I clean the 1380667 electrode instead of replacing it?
While light oxidation can be removed with fine steel wool, replacing the ICP 1380667 is recommended if the ceramic is compromised or the metal rod is severely pitted, as this ensures reliable flame rectification.

Is this part compatible with other ICP brands?
Yes, this 1380667 electrode assembly is a standard replacement part across the International Comfort Products family, including Heil, Quaker, Tempstar, and Comfortmaker units using Fenwal DSI systems.