Johnson Controls  P499RCP-107 Pressure Transducer

Johnson Controls P499RCP-107 Pressure Transducer

Johnson Controls

  • $247.00


The Johnson Controls P499RCP-107 is a high-performance electronic pressure transducer engineered for demanding HVACR applications, specifically optimized for high-pressure refrigerants like R-410A. This P499 series transducer features a stainless steel construction that ensures chemical compatibility with various non-corrosive refrigerants and oils. It provides a linear 0.5 to 4.5 Vdc ratiometric output, allowing for precise monitoring within a 0 to 750 psi range. Designed for professional installation, this unit includes a 1/4" SAE 45 degree flare internal thread (7/16-20 UNF) with an integrated Schrader depressor, facilitating a secure connection to standard service ports without the need for additional adapters. The Packard electrical connection ensures a moisture-sealed interface, essential for preventing signal drift in high-humidity mechanical rooms. This transducer is a reliable choice for condenser fan speed control, head pressure management, and compressor protection cycles, delivering the accuracy required for modern building automation systems and standalone electronic controllers.

Key Benefits for Contractors:
  • Broad Pressure Spectrum: The 0 to 750 psi capability makes it ideal for high-pressure systems and trans-critical CO2 applications.
  • Rugged Durability: Stainless steel sensing element protects against pressure spikes and environmental vibration.
  • Ease of Integration: Standard Packard connector and ratiometric signal allow for seamless replacement in legacy and new installations.
  • Leak Prevention: The internal flare thread with depressor minimizes refrigerant loss during installation and service.
  • Precise Signal: Low total error band ensures accurate feedback for advanced PLC and HVAC controllers.
Common Questions:

What is the primary application for the P499RCP-107?
This transducer is typically used for monitoring high-side discharge pressure in air conditioning and commercial refrigeration systems to manage fan cycling and head pressure.

Is this sensor compatible with R-410A systems?
Yes, the 750 psi rating is specifically designed to handle the operating pressures and surges associated with R-410A and other high-pressure refrigerants.

Does this unit require a specific wiring harness?
Yes, it utilizes a standard Packard style connector. If the existing harness is damaged, a compatible 3-wire Packard plug must be used to maintain the environmental seal.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question