Johnson Controls P66BAB-5 Control

Johnson Controls P66BAB-5 Control

Johnson Controls

  • $2,124.00


The Johnson Controls P66BAB-5 is a professional-grade electronic fan speed control designed for maintaining stable head pressure in air-cooled condensers during low-ambient conditions. Built with a dual input sensor model, this controller modulates the fan motor speed based on direct refrigerant pressure, specifically optimized for an operating pressure range of 190-250 psig. This unit features a 60-inch capillary with a 1/4 inch SAE brass flare nut, allowing for versatile mounting and reliable pressure sensing on the high side of the system. The start voltage is factory-calibrated at 40% of the supply voltage, ensuring the fan motor overcomes static friction immediately upon startup to prevent stalling or overheating. This HVAC pressure transducer control is engineered for 208/240V single-phase motors, providing precise modulation that extends the life of the compressor by preventing excessive cycling in cold weather environments.

Key Benefits for Technicians:

  • Precise Head Pressure Control: Maintains consistent condenser fan speed to stabilize system pressures during fluctuating ambient temperatures.
  • Dual Sensor Input: Enhances reliability in multi-circuit systems or complex HVACR refrigeration setups.
  • Field-Proven Durability: NEMA 1 enclosure protects internal components for long-term service in mechanical rooms and protected outdoor housings.
  • Reduced Maintenance: Minimizes mechanical wear on the fan motor and contactors compared to traditional on/off pressure switches.
  • Simplified Installation: The 5-foot capillary provides ample reach for high-side access ports without needing additional extensions.

Common Questions:

What is the start voltage setting on the P66BAB-5?
The unit is configured with a start voltage of 40% of the supply voltage, ensuring the motor starts at a speed high enough to initiate airflow immediately.

Which refrigerants are compatible with the 190-250 psig range?
This specific P66 Series control range is typically utilized for R-134a systems or other medium-pressure refrigerants requiring a 190 to 250 psig setpoint for stable operation.

Can this control be used with any fan motor?
No, the Johnson Controls P66 requires a motor designed for speed modulation (Permanent Split Capacitor - PSC) that is approved by the manufacturer for use with solid-state controllers.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.