KMC Controls CSC-3016-10 Control
The KMC Controls CSC-3016-10 is a high-performance pneumatic VAV reset volume controller designed for precise pressure-independent control of terminal units. As a sub-master air velocity controller, it utilizes a 0 to 2" WC differential pressure range to maintain consistent airflow regardless of duct static pressure fluctuations. This unit features a factory-calibrated 8 PSI reset start point and an adjustable reset span, allowing a master controller?Çösuch as a room thermostat?Çöto reset the velocity setpoint between 8 and 13 PSI based on load demand. Technical specifications include an air consumption rate of 28.8 scim at 20 PSI and a versatile damper selector that can be field-adjusted for normally open or normally closed operation. Built with a rugged ABS housing, the CSC-3016-10 is a reliable solution for cooling and heating sequences, offering independent adjustment knobs for minimum and maximum airflow setpoints to ensure optimal system balance and high-efficiency HVAC pneumatic control.
Key Benefits- Universal Application: Field-selectable for normally open (NO) or normally closed (NC) damper configurations.
- Precise Setpoints: Separate adjustment knobs for minimum and maximum CFM limits allow for tight mechanical balancing and energy efficiency.
- Sub-Master Control: Responds to thermostat branch signals for accurate reset of air velocity setpoints in variable air volume systems.
- Robust Design: Constructed with UL Flame Class 94 HB ABS material to ensure durability in demanding mechanical environments.
How do I change the damper action on this controller?
The unit is factory-set to Normally Open (NO). To switch to Normally Closed (NC), you must loosen the damper selection screw and align the "NC" arrow with the "DAMPER" arrow on the selection dial. Accuracy in this alignment is critical for proper operation.
What is the standard reset range for the CSC-3016-10?
The controller includes a factory-preset 8 PSI start point and a 5 PSI span, resulting in a standard reset range of 8 to 13 PSI. Both the start point and the span are field-adjustable from 0 to 10 PSI to match specific thermostat requirements.
Does this unit require specific mounting orientations?
Yes, these controllers are position-sensitive. For accurate differential pressure sensing, they must be mounted and calibrated in either a strictly horizontal or vertical plane as per the technical manual.