Resideo S8600H3002 Ignition Module

Resideo S8600H3002 Ignition Module

  • $196.00


Ignition Module, Intermittent Pilot, 24 Vac, 2 Second Maximum Falme Failure Response Time, No PrePurge, Lockout Ignition Sequence, Natural or LP Gas, Single Rod Flame Sense, Single Trial to Lockout, 90 Second Lockout Timing, 90 Second Ignition Trial Time, Manual Reset is Required on Lockout

Resideo S8600H3002 Ignition Module – Intermittent Pilot Control

The Resideo S8600H3002 Ignition Module is a premium OEM replacement part designed to provide safe, reliable ignition control, flame monitoring, and safety shutoff for intermittent pilot central furnaces and heating appliances. Engineered for use with natural gas or LP gas systems, this module ensures precise ignition sequences and rapid flame failure response for efficient and secure operation.

With a 2-second maximum flame failure response time and 90-second ignition trial, the S8600H3002 delivers dependable performance. Its lockout ignition sequence and manual reset requirement enhance system safety by preventing repeated ignition attempts in the event of a fault.


Key Features

  • Brand: Resideo

  • Model: S8600H3002

  • Type: Ignition Module, Intermittent Pilot

  • Voltage: 24 Vac

  • Ignition Type: Intermittent Pilot

  • Fuel Type: Natural Gas, LP Gas

  • Flame Sense: Single Rod

  • Ignition Trial Time: 90 seconds

  • Lockout Timing: 90 seconds, single trial to lockout

  • Pre-Purge: None

  • Flame Failure Response: 2 seconds max

  • Ignition Source: Internal high-voltage spark generator

  • Typical Ignition Hardware: Q345, Q3451

  • Typical Gas Control: VR8204, VR8304

  • Maximum Valve Load: 1 A Pilot / 1 A Main @ 24 VAC

  • Product Dimensions: 5.44" W x 3.94" H x 2.63" D (138 x 100 x 67 mm)

  • Ambient Operating Temp: -40°F to 175°F (-40°C to 79°C)

  • Certifications: CSA Design Certified


Applications

  • Intermittent pilot central furnaces

  • Heating appliances requiring precise flame monitoring and safety shutoff

  • Residential and commercial natural or LP gas systems

  • Replacement ignition module for Resideo HVAC systems


Safety Notice

This product must be installed by a qualified/licensed contractor and set up with properly calibrated test equipment. Improper installation can result in property damage, severe personal injury, or death. Resideo is not responsible for damages or injuries resulting from non-compliance with this warning.


Why Choose the Resideo S8600H3002

  • OEM-quality ignition module for reliable, safe operation

  • Fast flame failure response ensures maximum safety

  • Lockout ignition sequence prevents repeated ignition attempts

  • Durable construction for long-lasting HVAC system performance

  • CSA certified and engineered to meet strict safety standards

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.