Reznor 148588 Switch

Reznor 148588 Switch

Reznor

  • $145.00


The Reznor 148588 is a high-performance hi-limit switch designed for critical safety monitoring in industrial and commercial heating applications. As an essential HVAC replacement part, this auto reset limit control triggers at a precise 270F setpoint to prevent catastrophic heat exchanger damage and ensure the longevity of the blower system. It features a reliable 60-inch capillary sensor, or 60-inch temp bulb, which allows for versatile remote sensing and flexible installation in tight burner compartments where direct mounting is impractical.

Engineered for compatibility with specialized units such as the CAUA series, this high limit temperature switch functions as a fail-safe by interrupting the control circuit if internal temperatures exceed safe operating parameters. The Reznor 148588 provides consistent secondary protection for fan and limit control systems. Its durable construction is built to withstand the high-cycle demands of heavy-duty HVACR environments, ensuring that burner operations are held to strict thermal limits without frequent nuisance tripping from inferior sensing technology.

Key Benefits:
  • Precise 270F Thermal Cutoff: Provides reliable system protection against overheating by cutting power to the gas valve or blower.
  • Integrated 60" Capillary Tube: Facilitates remote temperature monitoring and allows for sensor placement in high-heat zones.
  • Automatic Reset Functionality: Restores normal operation once the equipment cools, reducing system downtime and service calls.
  • OEM Compatibility: Specifically designed to match Reznor unit heater specifications, including CAUA 150, 200, and 350 models.
Common Questions:
  • What causes a Reznor high limit switch to trip? High limit trips are typically caused by restricted airflow, such as dirty filters, a failing blower motor, or blocked vents, which lead to excessive heat buildup in the exchanger.
  • Can this switch be used in other heater brands? While this part is an OEM Reznor hi-limit switch, it may fit other equipment requiring a 270F trip point and a 60-inch capillary; however, always verify with regional technical specs before retrofitting.
  • Does the 148588 require a manual reset? No, this specific model is an auto reset limit control, meaning it will re-close the circuit automatically once the sensed temperature drops below the differential threshold.