Rheem-Ruud 42-23114-06K Relay
The Rheem-Ruud 42-23114-06K 24V SPDT Relay is a replacement HVAC control relay for compatible Rheem and Ruud heating and air conditioning equipment. Featuring a 24V control rating and single-pole, double-throw (SPDT) contacts, this relay provides normally open (NO) and normally closed (NC) switching paths for designated equipment control circuits.
The Rheem 42-23114-06K replacement relay is intended for applications requiring the specified relay configuration. When the relay changes state, its common contact transfers between the NC and NO terminals, allowing the control circuit to switch connected equipment functions. The actual switching application depends on the unit's wiring and control sequence.
Before installing this Ruud 24V switching relay, verify the original part number, control voltage type, contact load ratings, terminal arrangement, mounting configuration, and manufacturer-approved equipment compatibility. Do not substitute relays based on coil voltage alone.
Disconnect power, inspect the wiring and terminals, and follow the equipment manufacturer's wiring diagram. After installation, a qualified HVAC technician should verify proper relay operation and control-circuit performance.
Key Benefits
-
Rheem-Ruud 42-23114-06K part number for accurate replacement identification.
-
24V control rating for compatible HVAC control circuits.
-
SPDT contact configuration with normally open and normally closed switching paths.
-
Supports designated equipment control functions when correctly matched and installed.
-
Suitable for replacing a diagnosed defective relay in an approved Rheem or Ruud application.
Common Questions
Q: What does SPDT NO/NC mean on the Rheem-Ruud 42-23114-06K relay?
A: SPDT means single-pole, double-throw. The common contact switches between a normally closed (NC) terminal and a normally open (NO) terminal when the relay changes state.
Q: Can the Rheem-Ruud 42-23114-06K replace any 24V HVAC relay?
A: No. The control voltage, AC or DC coil requirements, contact ratings, terminal layout, mounting, and equipment compatibility must match the original relay.
Q: How can I determine whether the 42-23114-06K relay is defective?
A: A qualified technician should verify the control signal, check the coil and contact operation, and inspect the associated wiring and load circuit using the manufacturer's diagnostic procedures.
Disclaimer
While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
42-23114-06K is the cross for 42-23114-06