Rheem-Ruud 60-25076-02 Gas Valve

Rheem-Ruud 60-25076-02 Gas Valve

Rheem-Ruud

  • $509.00


For field technicians and contractors maintaining high-efficiency heating systems, the Rheem-Ruud 60-25076-02 Gas Valve is a critical OEM replacement component. This single-stage gas valve is engineered for natural gas applications, featuring a standard 1/2-inch NPT inlet and outlet connection to ensure seamless integration with existing gas piping infrastructures. Operating on a 24V intermittent pilot ignition system, the unit is factory-set to a 3.5" WC output pressure, providing the precise fuel regulation necessary for optimal combustion and furnace reliability. With a robust 200,000 BTU/HR capacity, this valve serves as the direct replacement for part number 624499R, maintaining factory specifications for safety and performance. This Honeywell VR8204 series equivalent is foundational for Rheem and Ruud furnace repair, offering a stable solution for gas valve troubleshooting in commercial and residential HVAC units. Utilizing genuine Rheem-Ruud OEM parts like the 60-25076-02 ensures the system operates within its design parameters, preventing the manifold pressure fluctuations that often lead to nuisance lockouts or inefficient heating cycles.

Key Benefits
  • Universal Compatibility: Specifically designed as an identical replacement for the 624499R gas valve, ensuring a drop-in fit without manifold modifications.
  • Precise Pressure Regulation: Factory-calibrated to 3.5" WC for natural gas, maintaining critical flame stability and heat exchanger efficiency.
  • High-Capacity Rating: Supports up to 200,000 BTU/HR, making it suitable for a wide range of Rheem, Ruud, and Richmond furnace models.
  • Standardized Connections: Features 1/2" x 1/2" NPT ports for compatibility with standard black iron or CSST gas lines.
  • Reliable 24V Logic: Integrates seamlessly with standard 24-volt HVAC control boards and intermittent pilot ignition systems.
Common Questions

Is the 60-25076-02 gas valve compatible with LP (Propane) systems?
This valve is factory-configured for natural gas. For liquid propane applications, a specific LP conversion kit (such as the 60-22513-03 spring kit) must be installed by a qualified technician to adjust the regulator for higher pressures.

What are the symptoms of a failing Rheem 60-25076-02 valve?
Common indicators include the furnace failing to ignite despite a spark or hot surface igniter glow, "no gas" faults on the logic board, or inconsistent manifold pressure. Always verify 24V at the gas valve terminals before replacing the component.

Can I use the 60-25076-02 to replace the 624499R?
Yes, the 60-25076-02 is identical to 624499R in fit, form, and function, serving as the direct manufacturer-authorized replacement.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.