Robertshaw 700-502 Gas Valve
The Robertshaw 700-502 Millivolt Gas Valve is a professional-grade combination gas control designed for standing pilot systems in commercial and residential heating. This 7000AMVR series valve features a 1/2" NPT inlet and 1/2" NPT outlet with additional side taps, offering a high-capacity throughput of 100,000 BTU. Engineered for wall thermostat actuation, it operates on a 250mV to 750mV signal, making it a reliable choice for furnaces, wall heaters, and boilers without requiring external line voltage. The unit comes factory-set for Natural Gas at a 3.5" WC regulation point, though it is field-convertible with the appropriate regulator kit. Techs will appreciate the straight-thru design and the inclusion of reducer bushings for versatile 1/2" x 3/8" applications. Built with a separate automatic pilot safety valve, it ensures immediate gas shutoff during pilot outage, maintaining system integrity in demanding environments.
Key Benefits
- Universal Installation: Multi-positional mounting capability (except upside down) allows for easy retrofitting in tight mechanical closets or equipment housings.
- Broad Compatibility: Replaces a wide range of Honeywell VS8148 and Allpoints millivolt valves used in vintage and modern gas-fired appliances.
- Reliable Pilot Safety: Features an independent automatic safety magnet and a manual gas cock (Off-Pilot-On) for standard service procedures.
- Integrated Protection: Includes inlet filtered screens and a pilot gas filter to prevent debris from fouling the internal diaphragm or orifices.
Common Questions
Can I use this gas valve for LP (Propane) applications?
The 700-502 is factory-configured for Natural Gas. To use it with LP, you must install a 1751-013 regulator conversion kit to achieve the required 11.0" WC pressure. Always verify the orifice size of the appliance before conversion.
Does this valve require a specific thermopile connection?
This model is designed for use with standard two-lead thermopiles. It features combination screw/spade terminals (1/4" and 3/16" NEMA standards) to ensure secure electrical contact and prevent miswiring during field replacement.
What should I check if the valve fails to open?
First, verify the millivolt output of the thermopile under load. If the closed-circuit reading is below 100mV, the valve may not actuate. Also, ensure the thermostat wiring hasn't exceeded the maximum recommended length for 750mV systems.
This item is not eligible for free shipping.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.