Weil McLain 386-902-006 Control

Weil McLain 386-902-006 Control

Weil McLain

  • $137.00


As an HVAC technician, you know that safeguarding a hydronic system against thermal runaway is non-negotiable. The Weil McLain 386-902-006 is a high-performance Honeywell L7248C-1030 series high limit control engineered specifically for Weil-McLain Ultra Oil boilers. This aquastat control serves as the primary safety interface, monitoring water temperature and enforcing a hard shutdown of the oil burner if the system exceeds the preset safety thresholds. Utilizing an adjustable set point range typically between 100°F and 240°F, this 120V component provides the precise thermal regulation required for high-efficiency boiler maintenance and failure prevention. With its integrated internal circuitry, the 386-902-006 manages the circulator pump and burner sequencing, ensuring the heat exchanger remains within its operating design limits. When you are performing a Weil-McLain boiler troubleshooting call, replacing a faulty limit control with this OEM HVAC replacement part is the only way to restore factory-spec safety and operational reliability to the heating plant.

Key Benefits for Contractors
  • System Protection: Acts as a critical safety barrier by immediately interrupting the burner circuit if boiler water temperatures reach hazardous levels.
  • OEM Compatibility: Designed for a seamless fit with the Weil McLain Ultra Oil boiler series, ensuring accurate sensor readings and terminal connections.
  • Integrated Logic: Features a manual reset capability and internal controls that coordinate with the thermostat and circulator for stable hydronic cycles.
  • Rugged Construction: Built to withstand the high-ambient environments of oil-fired mechanical rooms while maintaining calibration accuracy.
Common Questions & Technical Support
  • Which boiler models utilize the 386-902-006 control? This specific high limit is primary for the Ultra Oil (UO) series boilers. Always cross-reference your specific Series number with the manufacturer’s wiring diagram before installation.
  • Can this control be used as a replacement for the L7224 series? While they share similar footprints, the L7248C-1030 is calibrated for specific oil-fired parameters; verify your terminal layout (L1, L2, C1, C2) to ensure full functionality.
  • What does a 'limit trip' indicate on this unit? A trip usually suggests a failure in the primary operating control, an undersized expansion tank, or a malfunctioning circulator pump causing localized overheating.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question