White-Rodgers 36C84-912 Gas Valve

White-Rodgers 36C84-912 Gas Valve

White-Rodgers

  • $629.00


The White-Rodgers 36C84-912 Gas Valve is a 24V IP gas valve designed for precision fuel regulation in residential and commercial intermittent pilot ignition (IID) systems. This fast opening gas valve features a redundant pilot solenoid and a 3/4" x 3/4" NPT inlet and outlet, supporting capacities up to 280,000 BTU/HR for natural gas and 453,600 BTU/HR with the included LP conversion kit. As a critical component in HVAC gas valve replacement, the 36C84-912 replaces legacy 36E and 36C series controls, including the 36E86-302 and 36C84-412. Its integrated mercury flame sensor connection and 1/4" quick-connect terminals ensure compatibility with specialized millivolt and electronic spark-to-pilot configurations. The unit includes reducer bushings and 30-inch leads to accommodate various manifold geometries and wiring requirements found in older boiler and furnace applications.

  • Universal Compatibility: Serves as the direct White-Rodgers 36C84-912 cross reference for numerous 36E and 36C models, streamlining inventory for service technicians.
  • Enhanced Flow Control: Featuring a fast opening characteristic, it provides immediate gas delivery to the main burner once the pilot flame is established.
  • Field Versatility: The included LP conversion kit and reducer bushings allow for seamless adaptation between natural gas and propane setups.
  • Reliable Safety: The redundant solenoid design ensures secondary shut-off capability, crucial for meeting modern safety standards in intermittent ignition systems.

Common Questions

Can this valve be used in standing pilot systems?
No, the 36C84-912 is specifically engineered for cycle pilot or intermittent ignition systems (IID) and is not a direct replacement for standard standing pilot valves.

How do I adjust the outlet pressure on this model?
The regulator is factory-set at 3.5" W.C. for natural gas. Adjustments can be made by removing the regulator cover screw and turning the internal adjustment screw clockwise to increase or counter-clockwise to decrease pressure.

What does the redundant pilot feature provide?
The redundant valve design utilizes two internal valves in series. If one fails to close, the second provides a positive shut-off to prevent hazardous gas accumulation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Ask a Question
  • what is the wirong configuartion from the 36e86-302 to the new valve 36c84-912. Answereing this question may help folks decide to buy this valave. Thanks

    Please see links below for all the documentations we have on this valve.

    Inst Manual

    Tech Sheet