The Amana-Goodman 0130F00001P Pressure Switch is a critical OEM furnace safety component designed to monitor negative pressure and verify proper combustion blower operation. Engineered specifically for Goodman and Amana furnaces, this SPST pressure switch is factory-calibrated to a -1.20" PF (inches) set point. It maintains a Normally Open (NO) circuit that closes only when the inducer motor establishes the correct static pressure, ensuring the ignition sequence proceeds safely. This 0130F00001P model features a 1/4" barbed hose connection for a secure, leak-proof fit with standard silicone pressure tubing. Utilizing a genuine Goodman replacement part avoids the calibration drift and compatibility issues often associated with universal aftermarket switches. Whether you are addressing a furnace pressure switch stuck open error or performing preventative maintenance, this switch provides the exact technical specifications required for high-efficiency gas furnaces.
Key Benefits for HVAC Technicians- Factory-Calibrated Precision: Fixed -1.20" PF rating ensures the furnace operates within the manufacturer's tight safety tolerances.
- Secure Interfacing: Features a standard 1/4 inch barbed connection for quick integration with the inducer housing or collector box tubing.
- Direct OEM Replacement: Replaces Amana-Goodman part 0130F00001P, ensuring the electrical terminal orientation and mounting footprint match the original install.
- High-Reliability Switching: The Single Pole Single Throw (SPST) mechanism is built to handle the cycle counts required in residential heating applications.
- Enhanced Safety: Prevents gas valve energization if the venting system is obstructed or the draft inducer fails to meet the required CFM.
What does the -1.20" PF rating signify?
This is the specific negative pressure threshold (measured in inches of water column) required to close the 0130F00001P switch. If the inducer draft does not reach this level, the furnace will not fire.
Will this work on non-Goodman brands?
This part is specifically engineered for Amana, Goodman, and Janitrol equipment. Always cross-reference the 0130F00001P part number with your specific furnace model to ensure correct trip points.
Is the switch normally open or closed?
This is a Normally Open (NO) switch. It requires the physical force of the vacuum from the inducer motor to close the internal contacts and complete the circuit to the integrated furnace control board.