Bard HVAC 8201-050BX Relay
The Bard HVAC 8201-050BX Relay is a genuine 24V time delay relay specifically engineered for Bard wall-mount and packaged air conditioning units. As the direct OEM 8201-050 successor, this "BX" boxed version offers a standardized 5-minute delay on break (DOB) to ensure critical compressor short cycle protection. By maintaining a managed timing interval after a call for cooling ends or a power interruption occurs, this relay prevents the head pressure issues and winding stress associated with rapid restarts in high-demand commercial and industrial environments.
This HVAC control circuit relay is essential for technicians servicing WA, WH, and SH series units where precise equipment sequencing is required. The 8201-050BX features a robust solid-state timing design capable of handling up to 1.5A maximum amperage, providing the reliability needed for 24-volt legacy and current-generation Bard control boards. When replacing older 8201-050, 8201-025, or 8201-026 models, this unit serves as the authorized service replacement, ensuring the system meets original factory specifications for startup and shutdown delays.
Key Benefits for Contractors:- OEM Compatibility: Direct replacement for obsolete 8201-050, 8201-025, and 8201-026 relays.
- System Protection: Built-in 5-minute delay prevents nuisance trips and protects compressor longevity.
- Standardized Voltage: Designed for 24VAC control circuits common in Bard wall-mount systems.
- Boxed OEM Quality: Provided as a Bard 8201-050BX original part for guaranteed fit and terminal alignment.
- Verified Performance: UL-recognized and CSA-certified for professional HVACR applications.
Is the 8201-050BX a direct swap for the 8201-050?
Yes, the 8201-050BX is the current "boxed" OEM replacement for the original 8201-050. It maintains the same electrical characteristics and terminal layout for a straightforward field installation.
What is the primary function of this 24V relay?
It serves as an anti-short cycle timer. It holds the circuit open for approximately 5 minutes after power is removed, ensuring the refrigerant pressures equalize before the compressor attempts to restart.
Can I use this on non-Bard equipment?
While it is an HVAC time delay relay with standard 24V inputs, it is specifically calibrated for the logic cycles of Bard equipment. Always verify your unit's wiring diagram and timing requirements before utilizing it in universal applications.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.