The Burnham Boiler 105005-01 Float Switch Kit is the replacement condensate float switch kit for Burnham condensing boiler service. A condensing boiler squeezes so much heat out of its flue gas that water drops out of the exhaust, and that acidic condensate has to drain away continuously through the trap. The float switch is the safety device watching that drain. If water backs up because of a plugged trap, a sagging drain line or a frozen discharge, the float rises and signals the control to stop the burner before condensate can collect where it does damage.

The factory repair parts list for Alpine ALP080B through ALP285B boilers shows 105005-01 as the replacement condensate float switch kit, next to condensate trap kit 104704-01. The kit brings a light blue float switch with black wire leads and a threaded body, two spring clamps, a nozzle tip and a tube of silicone sealant. Having the clamps and sealant in the same package means the installation does not stall over small items while the heat is off and the customer is waiting in the next room.

Before you condemn the switch, find out why it tripped. A float that opened because the drain is full has done its job. Pull the trap, flush it, confirm the drain line slopes continuously to its termination and look for sludge or debris around the float. If the drain is clear and the switch still reads open, or it fails to change state when the float moves, replace it. Disconnect power first, note the wire routing, follow the supplied instructions for applying the sealant and allow it to cure as directed. Then pour water through the system and prove that the switch stops the burner.

Key Benefits

  • Condensate Safety Protection: A working float switch shuts the burner down when the drain backs up, protecting the boiler and the floor around it from standing acidic water.
  • Install Items Included: Two spring clamps, a nozzle tip and silicone sealant arrive with the switch, so the repair can be completed in one visit.
  • Factory Parts Match: Shown on the Alpine repair parts list as 105005-01, which takes the guesswork out of identifying the switch on covered models.
  • Clear Diagnostic Target: Replacing a switch that no longer changes state restores a dependable signal to the control and ends chasing intermittent drain faults.

Common Questions

  • What does the condensate float switch do? It senses water backing up in the condensate system and signals the boiler control to stop firing until the drain problem is corrected.
  • Which boilers use the 105005-01 kit? The factory repair parts list for Alpine ALP080B through ALP285B shows this kit number. For any other model, confirm the number against the parts list for that boiler.
  • My boiler locks out after I replace the switch. Why? The switch may be reporting a real blockage. Check the trap, the drain slope, any neutralizer media and the termination for restrictions, and verify the wire connections before looking further.