Burnham 108847-01 Limit Control

Burnham 108847-01 Limit Control

Burnham Boiler

  • $257.00


The Burnham 108847-01 High Limit Temperature Control is an OEM manual reset high limit with a 210°F trip point for Burnham hot water boilers. Its job is simple and critical: if the boiler water climbs to 210°F, the control opens its contacts, cuts the burner circuit and locks the boiler out. Unlike an automatic reset limit, a manual reset control stays open until someone presses the red reset button on the case, which forces a technician to find out why the boiler overheated before it fires again. The control is a gray enclosure with a Resideo label and a red push button marked to reset the switch.

The high limit is the safety backstop behind the boiler's operating control. The operating aquastat cycles the burner at the normal set point, and the 108847-01 only acts when something has gone wrong and the water temperature has run past that point. That makes the trip point important: a 210°F control is not interchangeable with a lower-temperature limit such as the 6016066, a Burnham manual reset limit switch that opens at 200°F. Always match the replacement's temperature and reset type to the original, and never jumper, bypass or raise a limit to stop a nuisance trip. The 108847-01 is a safety limit, not a substitute for the operating control.

When a high limit trips, the reset button is the symptom, not the cause. Common causes include no flow from a failed circulator or a closed zone valve, an air-bound loop, a scaled or dirty heat exchanger, an operating aquastat that failed and let the water run hot, or a limit that has drifted and trips early. Check flow and the operating control first, reset the limit once the cause is corrected, and watch the boiler through a complete heating cycle. If the limit trips repeatedly with confirmed good flow and a verified boiler temperature, or will not reset after the boiler has cooled, the control itself has failed and the 108847-01 should be replaced. Shut off the power before opening the control enclosure, and match the replacement to the boiler by model and serial number.

Key Benefits

  • Manual Reset Safety: Locks the burner circuit open after an overtemperature event until a technician presses the reset button.
  • 210°F Trip Point: A fixed 210°F high limit set point, matched to the original Burnham control.
  • Resideo Control: An OEM Resideo control built for hot water boiler limit duty.
  • Clear Reset Button: The red push button is marked for reset and is easy to find on the front of the case.

Common Questions

  • What temperature does the 108847-01 trip at? 210°F. The 6016066 is a 200°F manual reset limit, so the two are not interchangeable.
  • What does manual reset mean? After the control trips on high temperature, the burner circuit stays open until the red reset button is pressed, even after the boiler water cools.
  • Can it be used as the operating aquastat? No. The 108847-01 is a high limit safety control. The boiler's operating aquastat or control still sets the normal water temperature.