Emerson Alco 020846 Cage Replacement

Emerson Alco 020846 Cage Replacement

  • $547.00


The Emerson Alco 020846, specifically the X9144-B11B cage assembly, is a precision-engineered internal component designed for high-capacity THR series expansion valves. Engineered for refrigerant flow control in large-scale commercial and industrial systems, this replacement cage ensures reliable superheat regulation across multiple refrigerants. Its nominal capacity varies by medium, delivering 75 tons for R22, 70 tons for R407C, 55 tons for R134a, and 45 tons for R12. For low-temperature applications using R404A, R502, or R507, it maintains a consistent 48-ton rating. Built to withstand the rigors of high-pressure liquid lines, the X9144B11B cage provides a drop-in solution for HVAC system maintenance, restoring the valve’s modulation accuracy without requiring a full body replacement. The modular design allows technicians to address seat wear or debris-related failure efficiently, ensuring the thermostatic expansion valve (TXV) maintains peak evaporator efficiency and compressor protection.

Key Benefits for Technicians:

  • Optimized Flow Dynamics: Calibrated specifically for THR valve bodies to ensure precise refrigerant metering under varying load conditions.
  • Multi-Refrigerant Compatibility: Versatile performance ratings across HCFC, HFC, and legacy CFC refrigerants facilitate inventory consolidation.
  • Field Serviceability: Allows for rapid internal restoration of the TXV cage assembly, minimizing system downtime during emergency repairs.
  • Industrial Grade Durability: Constructed with robust materials to resist erosion and maintain seat integrity in high-tonnage liquid line applications.
  • Precise Nominal Capacity: Delivers up to 75 tons of cooling capacity, making it a critical component for large-scale chillers and refrigeration racks.

Common Questions:

What is the primary application for the X9144-B11B cage?
This cage assembly is designed specifically for Emerson Alco THR series valves used in high-capacity refrigeration and air conditioning systems where precise superheat control is required.

How do I determine if this cage is compatible with my existing valve?
Verify that your valve body belongs to the THR series and check the specific tonnage requirements for your refrigerant type, such as the 75-ton rating for R22 or 55-ton for R134a.

Can this cage be used with R507 systems?
Yes, the X9144B11B is rated at a 48-ton nominal capacity for both R404A and R507 refrigerant groups.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question