Emerson Alco 064283 Solenoid Valve

Emerson Alco 064283 Solenoid Valve

Emerson

  • $166.00


The Emerson Alco 064283 (Model 200RB7T7M) is a heavy-duty, pilot-operated refrigeration solenoid valve designed for high-capacity liquid, suction, or discharge gas service. Built for technicians who require field reliability, this 2-way normally closed valve features a 7/8" ODF sweat connection with extended copper ends, allowing for straightforward brazing without the need for internal disassembly. It is specifically engineered to handle significant cooling loads, offering a refrigerant capacity of 17 tons for R22 and 12.7 tons for R134a, making it a staple for commercial HVACR systems. The integrated manual stem provides a critical override for system testing and emergency bypass during power loss or maintenance cycles. Utilizing a PTFE O-ring for superior external sealing and a maximum operating pressure differential (MOPD) of 300 psig, this normally closed solenoid valve ensures tight shut-off and consistent performance even in high-pressure refrigeration valve applications.

Key Benefits:
  • Extended Copper Ends: Facilitates rapid installation and secure brazing connections while protecting the valve body from heat damage.
  • Integrated Manual Stem: Allows for manual override and simplified troubleshooting of the refrigerant circuit without energizing the coil.
  • High-Pressure Tolerance: Rated for a maximum working pressure of 500 psig and a maximum fluid temperature of 250°F.
  • Multi-Refrigerant Compatibility: Optimized for use with R22, R134a, R404A, R507, and other common HCFC/HFC refrigerants.
  • Maintenance-Friendly Design: Features field-serviceable parts and a universal coil family that fits across all 200RB series bodies.
Common Questions:

Can this valve be mounted in any orientation?
For optimal performance, it is recommended to mount the valve with the solenoid coil in the vertical upright position; mounting more than 90° from vertical is not advised.

What is the minimum pressure drop required for operation?
As a pilot-operated valve, it requires a minimum operating pressure drop of 2 psi to ensure the diaphragm or piston shifts correctly from the closed to open position.

Does the valve include the solenoid coil?
The 200RB7T7M is typically supplied as a valve less coil (VLC). You must select the appropriate voltage coil (AC or DC) to match your system's electrical requirements.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question