Field Controls 46399363 Control Kit

Field Controls 46399363 Control Kit

Field Controls

  • $676.00


The Field Controls 46399363 Control Kit (Model CK-63) is a specialized 120 VAC system control engineered for oil-fired power venting applications. Functioning as the direct replacement for the legacy 46139961, this kit provides a critical interface between your SWG Series Power Venter and the heating appliance. It features a high-sensitivity draft proving switch and an adjustable electronic post purge timer to clear residual flue gases and prevent nozzle carbonization. The integrated WMO-1 secondary safety switch offers additional protection by monitoring for blocked flue conditions or inadequate draft. Designed for veteran contractors, this venter burner control kit can operate burner motors up to 1/3 HP simultaneously with the venter, significantly reducing cycle times when utilized with a delayed oil solenoid valve. Ensure consistent negative pressure and system reliability with this field-proven oil power venter control, which remains the standard for safe sidewall venting in residential and light commercial oil-fired systems.

Key Benefits
  • Universal Oil Compatibility: Engineered to control all standard 120 VAC oil-fired systems and Field Draft Inducers.
  • Enhanced Safety: Includes a WMO-1 Blocked Vent Switch for redundant safety and draft verification.
  • Adjustable Post Purge: Solid-state timer allows for precise adjustment of post-cycle venting to maximize heat exchanger longevity.
  • Direct Replacement: Simplifies service calls by serving as the updated substitute for the obsolete 46139961, CK-61, and CK-62 models.
  • Simultaneous Operation: Capable of firing the burner motor and venter concurrently for improved sequence efficiency.
Common Questions

Is the CK-63 compatible with 24V control circuits?
Standard 46399363 kits are configured for 120 VAC. For applications requiring dual 24V/120V flexibility, the CK-63A alternative is typically recommended, though the CK-63 is the dedicated choice for pure 120V oil systems.

Does this kit include the delay oil valve?
No, the simultaneous burner/venter operation requires a delayed oil solenoid valve on the burner, which must be sourced separately if not already installed.

What is the typical post purge setting?
For most oil-fired heating appliances, a post purge of 3 to 5 minutes is standard, though this can be reduced to 1-3 minutes if running the burner simultaneously with the venter.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.