Carrier HK06NB065 Pressure Switch

Carrier HK06NB065 Pressure Switch

Carrier

  • $291.00


The Carrier HK06NB065 Pressure Switch is a critical safety component engineered for precise monitoring of combustion air and flue gas venting within residential furnaces and light commercial HVAC units. This SPST (Single-Pole Single-Throw) switch is factory-calibrated to a 0.8-inch water column (.8" WC) set point, ensuring it closes only when the necessary static pressure is achieved to allow the ignition sequence to proceed. As a Genuine OEM Carrier Replacement Part, it offers a direct fit and technical consistency for technicians servicing Carrier, Bryant, and Payne gas-fired systems. Utilizing a durable silicone diaphragm and robust contact housing, the HK06NB065 replaces older revisions like the HK06NB065A, maintaining mechanical stability and accurate 0.2" WC differential performance across a wide range of operating temperatures. Incorporating this HVAC draft pressure switch into your service routine ensures long-term reliability and code compliance for high-efficiency heating applications.

Key Benefits
  • Precise Pressure Calibration: Factory-set at 0.80" WC with a 0.2" WC differential to ensure accurate inducer motor verification.
  • OEM Compatibility: Designed specifically for seamless integration with Carrier heating systems, reducing diagnostic time and installation errors.
  • Durable SPST Logic: Features a high-integrity Single-Pole Single-Throw configuration for reliable circuit closure under demanding thermal cycles.
  • Safety Compliance: Acts as a primary fail-safe to prevent gas valve operation in the event of improper venting or draft failure.
Common Questions
  • What does a 0.8" WC rating mean for this switch? This rating indicates the specific suction or positive pressure required to actuate the internal diaphragm and close the electrical circuit.
  • Can the HK06NB065 replace other 0.8" WC switches? While the pressure rating may be the same, it is essential to verify the Carrier part number and terminal orientation to ensure correct fitment and safety logic.
  • What causes this pressure switch to trip? Common issues include blocked vent pipes, a failing inducer motor, or moisture buildup in the sensing lines that prevents the .8" WC threshold from being met.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question