The Honeywell Analytics 301-C-DLC-BIP Controller serves as a robust central command for heavy-duty gas detection networks, providing a direct replacement for the legacy VA301C-DLC-BIP. Engineered for mechanical rooms, cold storage, and industrial refrigeration plants, this unit manages up to 96 transmitters across three distinct channels. By utilizing BACnet/IP output, the 301-C-DLC-BIP allows for seamless BMS integration and high-speed data transmission over standard Ethernet architectures. The integrated datalogger provides a critical audit trail by recording up to 768 events, including alarm activations and system faults. Built with a durable ABS polycarbonate enclosure, it supports up to 128 zoning groups and 96 relay modules, ensuring scalable protection for complex facilities. This controller maintains Modbus compatibility for field devices while pushing critical diagnostics to the building's front-end via BACnet.
Key Benefits
- System Scalability: Manages up to 96 inputs/outputs and 128 zoning groups, allowing for massive refrigerant leak detection arrays.
- Advanced Communication: Native BACnet/IP support eliminates the need for external gateways when connecting to modern automation systems.
- Field Networking: Supports up to 2,000 feet of wiring per channel, providing localized control over large HVACR footprints.
- Programmable Logic: Features fully adjustable alarm levels with 0-99 minute time delays to prevent nuisance tripping of ventilation systems.
- Environmental Resilience: Rated for operation from -4°F to 122°F, making it suitable for both mechanical rooms and ambient industrial environments.
Common Questions
Can this controller be used with existing Modbus sensors?Yes, the 301-C-DLC-BIP communicates with field transmitters via Modbus RTU over three RS-485 channels while simultaneously outputting data to a supervisor via BACnet/IP.
Does this unit support remote data logging?The controller features a built-in datalogging function to store event history locally, which can be reviewed to ensure compliance with occupational safety and refrigeration standards.
Is the 301-C-DLC-BIP suitable for replacement of older VA301C models?This is the designated direct replacement for the VA301C-DLC-BIP, maintaining compatibility with existing wall mounting points and sensor networks.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.